Chapter 7 Troubleshooting
7.1 Check List
-
When the general status of ETERNUS Web GUI is
Check whether the QSFP cables are connected in the correct order or check that the "●" (IN)
and "■" (OUT) side of the QSFP cable is connected correctly. If not, use the following
procedure to reconnect the QSFP cables.
When the FAULT LED blinks
Check the general status and the system messages in ETERNUS Web GUI. A general status of
requires preventive maintenance.
In the details screen for each component, check the detailed information for each component
with a
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
Check that the "●" (IN) and "■" (OUT) side of the QSFP cable is connected correctly. If the
QSFP cable is connected incorrectly, use the following procedure to reconnect the QSFP
cable.
Procedure
1 Press the controller enclosure's Power switch for four seconds or more to turn off
the ETERNUS DX Disk storage system, and turn off the AC power.
2 Reconnect the QSFP cable.
3 Make sure that power is being supplied, then turn the ETERNUS DX Disk storage
system on.
Procedure
1
Press the controller enclosure's Power switch for four seconds or more to turn off the
ETERNUS DX Disk storage system, and turn off the AC power.
2
Reconnect the QSFP cable.
3
Make sure that power is being supplied, then turn the ETERNUS DX Disk storage
system on.
indicates that the ETERNUS DX Disk storage system contains a component that
and contact your maintenance engineer.
When checking the general status via ETERNUS CLI, refer to "ETERNUS
CLI User's Guide".
Copyright 2011 FUJITSU LIMITED
84
End of procedure
End of procedure