Fujitsu Eternus DX80 S2 User Manual page 103

Disk storage system
Hide thumbs Also See for Eternus DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Event type
P 0ASSMMvp 2
P 0BSSMMnn 2
P 0CSSMM00 2
P 0ESSMM00 2
P 0FSSMM00 2
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
code
TrapItemID
No.
0A00MMvp
0B00MMnn
0C00MM00
0E00MM00
0F00MM00
Copyright 2011 FUJITSU LIMITED
Upper: Message
Trap
Sensor
Lower: Description
Info
-
Controller Module#m(zz) EXP#v Out Port#p
Fault <pppppppppppp ssssssssss rrrrr>
CM EXP Out port is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
v: EXP number (0)
p: Port number (0)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz) Cache(MEM #xGB)
Slot#nn Fault <pppppppppppp ssssssssss
rrrrr>
CM memory is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
x: Capacity of the cache memory (2 or 4)
nn: Slot number of the cache memory (0)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz) BUD(#xxGB) Fault
<pppppppppppp ssssssssss rrrrr>
CM BUD is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
xx: Capacity of BUD (2)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz) NAND Controller
Fault <ppppppppppppp ssssssssss rrrrr>
CM NAND Controller is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
-
Controller Module#m(zz) SCU Fault
<pppppppppppp ssssssssss rrrrr>
CM SCU is disconnected.
SS: Component subtype
MM: CM module ID (10 – 11)
m: CM number (0 – 1)
zz: Model name (DX80S2 or DX90S2)
pp...: Component number
ss...: Serial number
rr...: Version
103
Remarks
These messages
are notified when
"Parts error" is
enabled for Error
Severity Level in
the event notifica-
tion setting. They
are not notified
during mainte-
nance operations.
P3AM-4842-01ENZ0