Fujitsu Eternus DX80 S2 User Manual page 134

Disk storage system
Hide thumbs Also See for Eternus DX80 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Sense code
SK
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
06
ETERNUS DX80 S2/DX90 S2 Disk storage system User's Guide -Operation-
ASC
ASCQ
F2
88
Rebuilding to a hot spare or a replaced disk is
complete, but Bad Data (data lost identifier) exists.
F2
8A
Rebuilding to a hot spare is halted.
F2
8B
Rebuilding to a replaced drive is halted.
F2
8C
Copyback is halted.
F2
8D
Copyback is halted because an error is found in the
copy source drive.
FB
01
CM error is detected.
FB
02
CM DMA port error is detected.
FB
03
CM BIOS error is detected.
FB
04
CM RTC error is detected.
FB
05
CM NVRAM error is detected.
FB
06
CM EXP error is detected.
FB
08
CM DI port error is detected.
FB
09
CM EXP IN port error is detected.
FB
0A
CM EXP OUT port error is detected.
FB
0B
Many correctable errors occurred in the CM memory.
FB
0C
CM BUD error is detected.
FB
0D
CM FAN error is detected.
FB
0E
CM NAND Controller error is detected.
FB
0F
CM SCU error is detected.
FB
10
CA error is detected.
FB
11
CA port error is detected.
FB
21
CM FPGA error is detected.
FB
22
CM LAN port error is detected.
FB
7A
CE exhaust temperature error is detected.
FB
7B
CE intake temperature error is detected.
FB
80
SMART is reported from the 3.5" HDD.
FB
81
SMART is reported from the 2.5" HDD.
FB
84
SMART is reported from the 3.5" SSD.
FB
85
SMART is reported from the 2.5" SSD.
FB
90
DE IOM error is detected.
FB
91
DE port error is detected.
FB
9A
DE QSFP port error is detected.
FB
D2
PSU error is detected.
Copyright 2011 FUJITSU LIMITED
Description
134
Remarks
These sense codes are notified when
"Rebuild complete (BAD DATA)" is
enabled for Error Severity Level in the
event notification setting.
They are not notified during mainte-
nance operations.
These sense codes are notified when
"Rebuild/Copyback (Non-
Redundancy)" is enabled for Error
Severity Level in the event notification
setting.
They are not notified during
maintenance operations.
These messages are notified when
"Parts warning" is enabled for Warning
Level in the event notification setting.
They are not notified during mainte-
nance operations.
These messages are notified when
"Sensor (Temperature) warning" is
enabled for Warning Level in the event
notification setting.
They are not notified during mainte-
nance operations.
These messages are notified when
"HDD/SSD warning" is enabled for
Warning Level in the event notification
setting.
They are not notified during mainte-
nance operations.
These messages are notified when
"Parts warning" is enabled for Warning
Level in the event notification setting.
They are not notified during mainte-
nance operations.
P3AM-4842-01ENZ0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx90 s2

Table of Contents