Administrator's Guide SoundPoint IP / SoundStation IP
Type
0 - seconds.milliseconds
1 - absolute time with minute resolution
2 - absolute time with seconds resolution
A - 76
Each event in the log contains the following fields separated by the | character:
•
time or time/date stamp
•
1-5 character component identifier (such as "so")
•
event class
•
cumulative log events missed due to excessive CPU load
•
free form text - the event description
Example:
011511.006|so
time stamp
ID
event class
missed events
text
Three formats are available for the event timestamp:
Example
011511.006 -- 1 hour, 15 minutes, 11.006 seconds since
booting.
0210281716 -- 2002 October 28, 17:16
1028171642 -- October 28, 17:16:42
Two types of logging are supported:
•
Basic Logging <level/><change/> and <render/>
•
Scheduled Logging Parameters <sched/>
|2|00|soCoreAudioTermChg: chassis -> idle