Removing The Standoffs - Montigo H36PVN Installation & Maintenance Manual

Power vent flush face fireplace
Table of Contents

Advertisement

Removing the Stand-off Panels:
The H36PVN is supplied two (2) two Stand-off Panels (RH & LH) that
hold the firebox refractory Lining in place . These panels are fastened
directly to the interior sides of the firebox with sheet metal screws . To
remove the panels follow the steps described below:
Step 1.
Remove the two (2) RH-TOP machine screw that hold
the Side panels in place, then the bottom two (2) machine screws,
Figure 24 . (Philips head screwdriver required).
1
Top
2
3
4
Figure 24. (Removing interior stand-off panel hardware).
Step 2.
Tilt the panel out from the top, and remove the panel from
the firebox . Pull out of the firebox straight, toward you without hitting
the Grate or panel Retaining brackets, Figure 24a .
Note: Place the panel somewhere safe where it will not get
damaged.
Grate
Figure 24a. (Removing interior stand-off panels).
Step 3.
Follow step1 & 2 to remove the LH-Side panel, Figure 24
& 24a . (Philips head screwdriver required).
XG0649 - 031511
Maintenance
Figure 24. (Inset).
Side panel
retaining bracket,
4-places
H36PVN Power Vent Indoor Gas Fireplace
Removing the Access Panel:
The H36PVN is supplied one (1) one interior access Panel (RH-side)
that contains the electronics and power control circuits . This panel is
fastened directly to the interior of the firebox with sheet metal screws .
To remove the panel follow the steps below:
Step 1. Remove the RH Refractory Panel as described in Figure 22 .
Step 2. Remove the RH Refractory Stand-off Panel as described
in Figure 24 & 24a .
Step 3. Having these two steps completed, remove the eight (8)
machine screw that hold the Side panels in place, Figure 26 . (Philips
head screwdriver required).
Step 4. Slightly tilt panel, and pull out between the grate and firebox
wall, Figure 26a .
Access Panel
hardware
,
7-pcs
Figure 26. (Removing the panel hardware). Figure 26a. (Removing the panel from
12d).
12).
Figure 26b. (A/C Connections, Gas
module and fireplace chassis). See figure
13, Schematic).
Power Vent
Control Access
Panel
Grate
the firebox).
Blk
Wht
12f)
Figure 26c. (Remote LVT Switch
connection). See figure 13, Schematic).
Page 31
.

Advertisement

Table of Contents
loading

Table of Contents