Montigo H36PVN Installation & Maintenance Manual

Power vent flush face fireplace
Table of Contents

Advertisement

Installation & Maintenance Manual
H36PVN Shown
XW2002
XW2004
C
XG0694
DANGER
Read and understand this manual.
Improper installation, adjustment,
alteration, service or maintenance
can cause serious injury, property
damage
or
even
death.
assistance or additional information
consult a qualified installer, service
agency or the gas supplier.
CAUTION
Glass doors on gas fireplaces are
extremely hot while the fireplace is
on and remain hot even after the
fireplace has been turned off. Safety
screens are available and can reduce
the risks of severe burns. Please
keep children away from the fireplace
at all times.
®
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H36PVN Shown
For
XW2006
XW2012
XW2014
H36PVN
Power Vent
Flush Face
Fireplace
WARNING
Do not store or use gasoline or any
other flammable vapors and liquids in
the vicinity of this or any other gas
burning appliance. A fire or explosion
my occur causing serious injury,
property damage or even death.
NOTICE
Installer: Leave this manual with the
appliance. Do not remove.
Consumer: Retain this manual for
maintenance and future reference. Do
not Discard.
NOTICE
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Immediately call your gas supplier
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
from a neighbor's phone. Follow the gas
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Blank
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
supplier's instructions.
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
If you cannot reach your gas supplier,
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
call the fire department.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
H36PV Manual
030711

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H36PVN

  • Page 1 Danger of harming radiation Environment your hands Irritant Slippery floor Watch your step Cutting High temperatures Glass hazard Danger of suffocation XW2014 XG0694 030711 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H36PVN Power Vent Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. XW2010 Table of Contents Safety Alert Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Multi-Elbow Vertical Vent .
  • Page 3: Safety Alert Key

    Introduction Warranty and Installation Information: (See Appendix B) INTRODUCTION The Montigo warranty will be voided by, and Montigo disclaims Congratulations on your purchase of a Montigo Fireplace . any responsibility for, the following actions: ► Modification of the fireplace and/or components including Direct-Vent assembly or glass doors .
  • Page 4: Installation

    ■ Refer to the Section 4 on Page 10, "Installing the Power NOTICE Vent" for details . ■ Montigo supplies 20' of low voltage wire, which can be spliced to any length . This wire CANNOT run in conduit Installation and repairs should be done by an with any other wire .
  • Page 5: Section 1: Installation Overview And Product Dimensions

    Please review the Pre-Installation Checklist on Page 4 Clearances for general information on preparing for a successful installation of your fireplace. To ensure the H-Series H36PVN Fireplaces operate safely, all The H-Series H36PVN & fireplace models must maintain the following clearances . The H36PVN fireplaces may be installed in any location that...
  • Page 6: Section 2: Framing The Fireplace

    45½" from floor . gas service shut-off valve; according to local gas codes, then secure Non-combustible Header (supplied by montigo), install to allow 15½” of Non-combustible cement board to fasten above the glass of the unit and Non-combustible header.
  • Page 7: Section 3: Finishing

    Step 1. As shown in Figure 3; Use Non combustible Cement board, at sides of unit (see figure 2a on page 6) using sheet metal screws . supplied by Montigo, screw to Non-combustible Header and 2 x 4's Non-combustible Cement Board (supplied by montigo).
  • Page 8: Combustible Mantles And Facings

    H36PVN Power Vent Indoor Gas Fireplace Installation To Ceiling Drywall/ 16” Combustible Construction Combustible Construction 15” allowed in shaded area 14” 13” First Combustible 12” Header @ 50" 11” from floor or 8” 10” from top of unit 9” 8”...
  • Page 9: Section 4: Installing The Power Vent

    Section 4: Installing the Power Vent Multi-Elbow Installations Montigo supplies a variety of power venting options The location of Multi-elbow installations are possible up to a maximum of six the power vent should be selected and laid out to provide the shortest at 90°...
  • Page 10: Venting Components

    Place the springs, supplied with the pipe kit, between the „ outer and inner pipes to keep the pipes separate and avoid any possible hot spots . Montigo recommends the use of a flex section for the final „ 18” pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement .
  • Page 11: Installation Of The External Roof Mounted Power Vent

    All venting material must be sealed with high heat silicone sealant RV230. All venting material to be Montigo flex pipe, with as few joints as possible. All joints use MVA vent splice, sealed thoroughly with silicone. Montigo will not be held responsible...
  • Page 12: Installing The External Roof Mounted Power Vent Module

    H36PVN Power Vent Indoor Gas Fireplace Installation Step 5. Install the Power Vent, Roof-top Stainless steel cover over the Installed Rough-in Kit . (You can see the Electrical harness connector in the top right corner) . Electrical Harness from Power Vent...
  • Page 13: Installing A Wall Mounted Vertical Exterior Power Vent

    All venting material must be sealed with high heat silicone sealant RV230. All venting material to be Montigo flex pipe, with as few joints as possible. All joints use MVA vent splice, sealed thoroughly with silicone. Montigo will not be held responsible...
  • Page 14: Venting Components

    ■ Place the springs, supplied with the pipe kit, between the outer and inner pipes to keep the pipes separate and avoid any possible hot spots . ■ Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater 9 11/16"...
  • Page 15: Installation Of The External Wall Mounted Power Vent

    H36PVN Power Vent Indoor Gas Fireplace Installation Installing the external wall mounted power vent module Step 4. Insert the conduit from the Power Vent Module into the rough-in Step 1. Construct a frame for the termination opening to meet the frame through the two top right entry holes . Remove the nut from the following requirements: supplied strain relief and place as shown, Figure 7c .
  • Page 16 H36PVN Power Vent Indoor Gas Fireplace Installation Installed Power Vent Connector Tightened hardware, 6-pcs. CAUTION ■ Vent terminations can be very hot. The termination is to be installed higher than 7 feet Figure 7e. (Assembled Rough-in Kit) above a public walkway.
  • Page 17: Installing In-Line Linear Power Vent

    H36PVN Power Vent Indoor Gas Fireplace Installation Installing an In-Line Linear Power Vent (LDVPV58) Example B. Horizontal mounting with horizontal termination This section applies to installations where an external roof Venting Installation or wall mounted power vent is not aesthetically acceptable Maximum Minimum Max. # or feasible. Vent Run Vent Run** Elbows Venting Layout 60 Feet 20 Feet Selection of components and details of venting lay out should ** from fireplace to in-line power vent adhere to the following guidelines: Horizonta Insta Ensure there is a minimum run of 2’...
  • Page 18: Venting Components

    . Vertical Flex Pipe Montigo recommends the use of a flex section for the final „ pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement .
  • Page 19 DATE DIMENSIONS ARE IN INCHES TOLERANCES: NOTE: 7/29/2010 DRAWN BY FRACTIONAL 1/32" The H36PVN requires a specific volume of atmospheric interchange TWO PLACE DECIMAL .015" CHECKED BY THREE PLACE DECIMAL .005" to operate properly and efficiently MATERIAL ALL BENDS ARE ASSUMED VLWB-8 SIZE DWG.
  • Page 20: Section 5: Wiring

    The Fireplace A/C power and Power Vent harness's must be installed Step 2. Locate all the Power vent connections & ports, Figure 12b . before completing the installation of the H36PVN Fireplace. These connections are made from the RH-Side of the fireplace, Figure 12 through Figure 12f.
  • Page 21: Installing The Remote Switch

    Route the Power Vent Comunication conduit into the cover as shown, and connect to the communication Port, Figure 12d . Installing The Remote Switch The H36PVN's Remote LVT (Low Voltage) Switch conduit is located Note on the RH Side of the fireplace .
  • Page 22: Hsi Wiring Schematic

    H36PVN Power Vent Indoor Gas Fireplace Installation WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. XW2008 Figure 13. Wiring schematic for the H36PVN. Page 22 XG0649 - 031511...
  • Page 23: Conduit & Wiring Clearances

    Connect the wiring to the linear power vent as outlined in the previ- ous section, and connect the wiring to the fireplace as outlined in the H36PVN schematic, figure 13. Ensure that the proper clearances are maintained for the wiring and conduit. When installing the wiring it must never run above the vent run and it must be at least 1"...
  • Page 24: Section 6: Installing The Gas Line

    Gas line sizing requirements will be determined in ANSI „ Z221 .3 National Fuel Gas Code in the USA and CAN/CGA The H36PVN is supplied one (1) one exterior access Panel (LH-side B149 in Canada . firebox) . This panel is fastened directly to the exterior of the firebox with sheet metal screws .
  • Page 25: Section 7:Removing & Installing The Door

    Installing & Removing the Door Section 7: H36PVN Power Vent Indoor Gas Fireplace Installation Section 7: Installing & Removing the Door Removing the doors: Step 3. Hold the Glass Removal Tools firmly, Lift the door upward, into the top door frame, Figure 17c . Then pull the bottom of the glass The doors are removed in a few simple steps .
  • Page 26: Section 8: Installing The Logset

    Step 3. Position Back Log 'A' from the previously unpacked package, (Figure 18) . Place the Log upright, (as shown Figure 18d) and The H36PVN is supplied with six (6) piece ceramic fibre logs . Install move the Log flush against the sheet metal Back Pan . Without...
  • Page 27 H36PVN Power Vent Indoor Gas Fireplace Installation Step 5. Position the Bottom Right Log 'B' and place Right end in the Step 8. Place Front Left Log 'E', with the Knots pointing in the sheet metal cradle (located at the far right of the Log Grate), Figure, directions shown, Figure, 18k .
  • Page 28: Operation

    ■ This fireplace will not operate unless the correct air movement is detected by our control system.. ■ Please consulted with your contact person at Montigo should you have any problems with your start up. XW2040 Page 28...
  • Page 29: For Your Safety - Read Before Lighting

    H36PVN Power Vent Indoor Gas Fireplace Operation Proflame SIT Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 30: Maintenance

    Removing the Log Grate: Step 1 & 2. Figure 20. (Pilot mounting machine screws). The H36PVN is supplied with a log Grate that is fastened directly to the base of the Fireplace . To remove the Grate, to perform certain Maintenance functions, follow the steps described below: Step 3 & 4. Figure 20a.
  • Page 31: Removing The Standoffs

    Removing the Stand-off Panels: Removing the Access Panel: The H36PVN is supplied two (2) two Stand-off Panels (RH & LH) that The H36PVN is supplied one (1) one interior access Panel (RH-side) hold the firebox refractory Lining in place . These panels are fastened that contains the electronics and power control circuits .
  • Page 32: Removing The Firebox Access Panel

    Have the fireplace and installation inspected yearly . The „ The H36PVN is supplied one (1) one interior access Panel (LH-side inspection must include, but is not limited to, the following: firebox) that contains the Gas valve, and electronics . This panel is fastened directly to the interior of the firebox with sheet metal screws .
  • Page 33: Troubleshooting

    H36PVN Power Vent Indoor Gas Fireplace Maintenance Section: Troubleshooting: (SIT - IPI Electronic) 1. Locate the lead to the battery backup, (remove) (Refer to schematic, below) 2. Locate the AC/DC wall transformer, (Unplug connector) (Refer to schematic, below) If your fireplace still does not operate correctly, consult your dealer or the manufacturer .
  • Page 34: Appendix A

    H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix A: Power Vent Locations Vertical Detail Horizontal Detail A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public † or balcony [30 inches (75 cm) minimum] property [*7 feet (2.1 m) minimum]...
  • Page 35: Vertical Power Vent Detail

    H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix A: Power Vent Locations EDVRSPV58 Vertical Power Vent Detail EDVWSPV58 Horizontal Power Vent Detail Wall 30”Min. “R” Eaves / Overhang Wall 30”Min. “ F” & “G” Wall 30”Min “R” Top View 30”Min . 30” (75cm) “H” & “I”...
  • Page 36: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 37: Appendix C

    H36PVN Power Vent Indoor Gas Fireplace Appendix amendment Appendix C: State of Massachusetts (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPa-54, Chapter 10 (1) Revise NFPa-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 38 H36PVN Power Vent Indoor Gas Fireplace notes Page 38 XG0649 - 031511...
  • Page 39 H36PVN Power Vent Indoor Gas Fireplace notes Page 39 XG0649 - 031511...
  • Page 40 H36 PV Power Vented Residential Gas Fireplace Ferndale, washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0649 - 031511...

Table of Contents