DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
XG0649
WARNING
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H36PVN
Power Vent
Flush Face
Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
NOTICE
This fireplace is certified to ANSI Z21.50 / CSA 2.22 Vented Fireplace Standard as a
power assisted direct vent fireplace. This product uses outdoor air for combustion and
and exhausts combustion products outdoors.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
Hot surface
Danger of entrapment
Danger of death
General Warning
Laser Radiation
Biohazard
Oxidising
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
C
®
US
18.01.30

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the H36PVN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Montigo H36PVN

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects ® XG0649 18.01.30 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H36PVN Power Vent Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Instruction Manual Contents Safety Alerts...
  • Page 3: Safety Alerts

    Introduction Warranty and Installation Information: (See Appendix B) Introduction The Montigo warranty will be voided by, and Montigo disclaims Congratulations on your purchase of a Montigo Fireplace. any responsibility for, the following actions: ► Modification of the fireplace and/or components including With over 30 years of experience, Montigo is committed to Direct-Vent assembly or glass doors.
  • Page 4: Section A: Before You Start

    Vent" for details. Installation and repairs should be done by an authorized gas fireplace service technician. ■ Montigo supplies 20' of low voltage wire, which can be The appliance should be inspected before use and at least annually by a professional. More spliced to any length.
  • Page 5: Rating Plate Sample

    H36PVN Power Vent Indoor Gas Fireplace Installation Rating Plate Sample Figure A: Rating Plate for IPI eletronic ignition Page 5 XG0649 - 180130...
  • Page 6: Section 1: Installation Overview And Product Dimensions

    To ensure the H-Series H36PVN Fireplaces operate safely, all The H-Series H36PVN & fireplace models must maintain the following clearances. The H36PVN fireplaces may be installed in any location that Clearances to Combustibles maintains proper clearances to air conditioning ducts, electrical wiring and plumbing.
  • Page 7: Section 2: Framing

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEA Non-combustible Header (supplied by montigo), install to allow 15½” of Non-combustible cement board to fasten above the glass of the unit and Non-combustible header.
  • Page 8 Step 1. As shown in Figure 3; Use Non combustible Cement board, at sides of unit (see figure 2a on page 6) using sheet metal screws. supplied by Montigo, screw to Non-combustible Header and 2 x 4's Non-combustible Cement Board (supplied by montigo).
  • Page 9: Section 3: Finishing

    H36PVN Power Vent Indoor Gas Fireplace Installation Section 3: Finishing To Ceiling Drywall/ 16” Combustible Construction Combustible Construction 15” allowed in shaded area 14” 13” First Combustible 12” Header @ 50" 11” from floor or 8” 10” from top of unit 9”...
  • Page 10: Section 4: Installing The Power Vent

    Section 4: Installing the Power Vent Multi-Elbow Installations Montigo supplies a variety of power venting options. The location of Multi-elbow installations are possible up to a maximum of six the power vent should be selected and laid out to provide the shortest at 90°...
  • Page 11: Venting Components

    18” outer and inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 12 H36PVN Power Vent Indoor Gas Fireplace Installation Installing the external roof mounted power vent module Step 3. Install the Power Vent Rough-in Kit. Pull wire harness through Step 1. the supplied hole in the bottom corner of the rough-in box, and snap into the slot provided, (See figure 5b inset).
  • Page 13 H36PVN Power Vent Indoor Gas Fireplace Installation Step 5. Step 7. Install the Power Vent, Roof-top Stainless steel cover over the Install the Power Vent Module. Place the Power Vent Module over the stainless steel cover flange and vent pipe, aligning the Installed Rough-in Kit.
  • Page 14: Venting Layout - Wall Mounted Vertical Exterior Power Vent

    H36PVN Power Vent Indoor Gas Fireplace Installation Installing a Wall Mounted Vertical Exterior Power Vent (EDVWSPV58) Multi-Elbow Installations This section applies to installations where the shortest possible vent Multi-elbow installations are possible up to a maximum of six run is through an exterior wall. Refer to Appendix A - Power Vent at 90°...
  • Page 15 ■ Place the springs, supplied with the pipe kit, between the outer and inner pipes to keep the pipes separate and avoid any possible hot spots. ■ Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater 9 11/16"...
  • Page 16 H36PVN Power Vent Indoor Gas Fireplace Installation Installing the external wall mounted power vent module Step 4. Insert the conduit from the Power Vent Module into the rough-in Step 1. Construct a frame for the termination opening to meet the following requirements: frame through the two top right entry holes.
  • Page 17 H36PVN Power Vent Indoor Gas Fireplace Installation Installed Power Vent Connector Tightened hardware, 6-pcs. CAUTION ■ Vent terminations can be very hot. The termination is to be installed higher than 7 feet above a public walkway. Figure 7e. (Assembled Rough-in Kit) ■...
  • Page 18 WARNING CAUTION All venting material must be Montigo flex pipe, with as few joints ■ Vent terminations can be very hot. The termination is to be installed higher than 7 feet as possible. All joints use MVA vent splice. Montigo will not be above a public walkway.
  • Page 19 Elbow outer and inner pipes to keep the pipes separate and avoid any possible hot spots. Vertical Montigo recommends the use of a flex section for the final „ Flex Pipe pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 20 DATE DIMENSIONS ARE IN INCHES TOLERANCES: NOTE: 7/29/2010 DRAWN BY FRACTIONAL 1/32" The H36PVN requires a specific volume of atmospheric interchange TWO PLACE DECIMAL .015" CHECKED BY THREE PLACE DECIMAL .005" to operate properly and efficiently MATERIAL ALL BENDS ARE ASSUMED VLWB-8 SIZE DWG.
  • Page 21: Section 5: Wiring

    The Fireplace A/C power and Power Vent harness's must be installed Step 2. Locate all the Power vent connections & ports, Figure 12b. before completing the installation of the H36PVN Fireplace. These connections are made from the RH-Side of the fireplace, Figure 12 through Figure 12f.
  • Page 22 Route the Power Vent Comunication conduit into the cover as shown, and connect to the communication Port, Figure 12d. Installing The Remote Switch The H36PVN's Remote LVT (Low Voltage) Switch conduit is located Note on the RH Side of the fireplace.
  • Page 23 If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Connect to DC wall transformer. See Figure 13a. Figure 13. Wiring schematic for the H36PVN. Page 23 XG0649 - 180130...
  • Page 24: Conduit & Wiring Clearances

    Connect the wiring to the linear power vent as outlined in the previ- ous section, and connect the wiring to the fireplace as outlined in the H36PVN schematic, figure 13. Ensure that the proper clearances are maintained for the wiring and conduit. When installing the wiring it must never run above the vent run and it must be at least 1"...
  • Page 25: Section 6: Installing The Gas Line

    Gas line sizing requirements will be determined in ANSI „ Z221.3 National Fuel Gas Code in the USA and CAN/CGA The H36PVN is supplied one (1) one exterior access Panel (LH-side firebox). This panel is fastened directly to the exterior of the firebox B149 in Canada.
  • Page 26: Section 7: Installing & Removing The Screen And Door

    H36PVN Power Vent Indoor Gas Fireplace Installation Step 3. Remove the two (2) screen / glass door retainer slides by Section 7: Installing & Removing the Screen and Door pulling firmly with your fingers. Removing the doors: The screen and door are removed in a few simple steps.
  • Page 27 H36PVN Power Vent Indoor Gas Fireplace Installation Step 5. Hold the Glass Removal Tools firmly, Lift the door upward, Step 10. Hook the bottom tabs of the screen into the slots in the into the top door frame, Figure 17. Then pull the bottom of the glass screen / glass door retainer slides.
  • Page 28: Section 8: Installing The Log Set

    Installing the Logs: (Figure 18). Place the Log upright, (as shown Figure 18d) and The H36PVN is supplied with six (6) piece ceramic fibre logs. Install move the Log flush against the sheet metal Back Pan. Without as described below:...
  • Page 29 H36PVN Power Vent Indoor Gas Fireplace Installation Step 5. Position the Bottom Right Log 'B' and place Right end in the Place Front Left Log 'E', with the Knots pointing in the Step 8. sheet metal cradle (located at the far right of the Log Grate), Figure, directions shown, Figure, 18k.
  • Page 30: Section 9: Operation - Start Up Sequence

    H36PVN Power Vent Indoor Gas Fireplace Operation Section 9: Operation - Start up Sequence For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 31: Section 10: Maintenance

    Step 1 & 2. Figure 20. (Pilot mounting machine screws). The H36PVN is supplied with a log Grate that is fastened directly to the base of the Fireplace. To remove the Grate, to perform certain Maintenance functions, follow the steps described below: Step 3 &...
  • Page 32: Removing The Stand-Off Panels

    Removing the Stand-off Panels: Removing the Access Panel: The H36PVN is supplied two (2) two Stand-off Panels (RH & LH) that The H36PVN is supplied one (1) one interior access Panel (RH-side) hold the firebox refractory Lining in place. These panels are fastened that contains the electronics and power control circuits.
  • Page 33: General

    Have the fireplace and installation inspected yearly. The „ The H36PVN is supplied one (1) one interior access Panel (LH-side inspection must include, but is not limited to, the following: firebox) that contains the Gas valve, and electronics. This panel is fastened directly to the interior of the firebox with sheet metal screws.
  • Page 34: Troubleshooting (Only To Be Done By Qualified Service Personnel)

    Ensure the vent or the exhaust termination are not back ON automatically after sometime blocked by debris. Adjust the Fan speed higher and restart the fireplace. If failure persists, contact Montigo for support. If your fireplace still does not operate correctly, consult your dealer or the manufacturer.
  • Page 35: Appendix A: Power Vent Locations

    H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix A: Power Vent Locations Vertical Detail Horizontal Detail A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public †...
  • Page 36 H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix A: Power Vent Locations EDVRSPV58 Vertical Power Vent Detail EDVWSPV58 Horizontal Power Vent Detail Wall 30”Min. “R” Eaves / Overhang Wall 30”Min. “ F” & “G” Wall 30”Min “R” 30”Min . 30” (75cm) Top View “H”...
  • Page 37: Appendix B: Warranty

    (collectively referred to herein as "The Companies"), warrants the option, replace or repair defective components of the appliance Montigo gas appliance (referred to herein as 'the appliance') to manufactured by the company at no charge and will also pay for...
  • Page 38 In the event the installing dealer is unavailable, contact your nearest authorized Montigo dealer (www.Montigo.com) or contact Montigo direct at techsupport@ montigo.com. Ensure you have your sales receipt and the model and serial number of your appliance.
  • Page 39: Appendix C: State Of Massachusetts

    H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows:...
  • Page 40 H36 PV Power Vented Residential Gas Fireplace XG0649 - 180130...

Table of Contents