Montigo H38DF-CLCR Installation & Maintenance Manual

Indoor corner unit residential gas fireplace
Table of Contents

Advertisement

Installation & Maintenance Manual
DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
XG0213
CAUTION
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H38DF-CLCR
HL38DF-CLCR
HP38DF-CLCR
Indoor
Corner Unit
Residential
Gas Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
falling objects
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
040512.1

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38DF-CLCR

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects XG0213 040512.1 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H*38DF-CLCR Corner Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. Table of Contents INTRODUCTION .................3 Heat Shields ................16 BEFORE YOU START: ...............4 ▪...
  • Page 3: Introduction

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Before You Start

    Should it be impossible to meet the venting requirements laid out  BEFORE YOU START: in Section 3: Venting, please contact your local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight ...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    H*38DF-CLCR Corner Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Safety, as well as efficiency of operation, should be considered when Please review the Pre-Installation Checklist on Page 4 for general selecting the fireplace location. Select a location that does not interfere information on preparing for a successful installation of your fireplace.
  • Page 6: Section 2: Framing The Fireplace

    H*38DF-CLCR Corner Gas Fireplace Installation Section 2: Framing the Fireplace Frame in the enclosure for the unit with framing materials. The framed Top Vent Ceiling level opening for the assembled fireplace is 48 " wide, 44 " high, 25 1/4" deep, see Figure 2.
  • Page 7: Clearances

    H*38DF-CLCR Corner Gas Fireplace Installation nailing Flange Extension Clearances When installing a shelf over the top of the fireplaces, the following The 4" nailing flange extension is shipped attached to the top edge of guidelines must be adhered to: the fireplace, see Figure 1. For Rear Vent applications, the minimum clearance is 1"...
  • Page 8: Section 3: The Direct Vent System

    H*38DF-CLCR Corner Gas Fireplace Installation Section: 3 The Direct Vent System Montigo supplies a variety of direct venting and termination options. 3. Install the (removed) Rear flue cover and gasket material, to the The direct vent termination location MUST be selected such that Top vent outlet.
  • Page 9: Installing A Roof Mounted Termination

    H*38DF-CLCR Corner Gas Fireplace Installation Section 3-2: InSTALLInG A ROOF MOUnTED DIRECT VEnT PVTK1 TERMInATIOn (PVTK-1) Termination 2’ min. This section applies to installations where the direct vent termi- nation will be roof mounted. Support ring VEnTInG LAYOUT Selection of components and details of venting lay out should Support plate 32’...
  • Page 10: Standard Roof Vent (One Elbows No Offsets)

    H*38DF-CLCR Corner Gas Fireplace Installation PVTK1 Termination Storm Collar Support plate 32’ M a. x Support ring *18” Max. See Note below Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend). * note: Elbow must be installed directly off the back of the fireplace. If additional horizontal distance is required the vent run must be increased a 2:1 Horizontal to Vertical ratio.
  • Page 11: Installing A Wall Mounted Termination

    H*38DF-CLCR Corner Gas Fireplace Installation Section 3-3: InSTALLInG A WALL MOUnTED DIRECT VEnT 4). Installation of termination from inside structure TERMInATIOn A Termination with a MOSR Frame is installed from the inside of the This section applies to installations where the direct vent termi- structure.
  • Page 12: Venting Layout

    Venting runs must fall within the limits set by the venting graphs,  parameters, please contact a see Figure 12 or 12a. local Montigo dealer for Power Venting options. The Venting Graph Measure the vertical height from the fireplace hearth to the centre of the termination and the horizontal run from the fireplace flue collar to the wall flange of the termination.
  • Page 13: Top Vent, Wall Mounted Termination (Multi Elbow)

    H*38DF-CLCR Corner Gas Fireplace Installation Heat 150”max Shield Termination Solid Section Flex Section Exterior Wall Hearth Figure 13b. H38C*, HL38C* or HP38C* Top Vented, wall mounted Multi-elbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 12 or 12a. 126”...
  • Page 14: Rear Vent, Wall Mounted Graph, H*38C

    The Venting Graph parameters, please contact local Montigo dealer for Power Measure the vertical height from the fireplace hearth to the centre of Venting options. the termination and the horizontal run from the fireplace flue collar to the wall flange of the termination.
  • Page 15: Wall Mounted Termination Venting Components

    H - Roof Flashing PRF-7 (1/12 - 7/12 pt.) Montigo recommends the use of a flex section for the final pipe  PRF-12 (7/12 - 12/12 pt.) connected directly to the fireplace offering greater flexibility of...
  • Page 16: Heat Shields

    H*38DF-CLCR Corner Gas Fireplace Installation Heat Shields Installing a Wall Mounted RHS103 Heat shield. Use the RHS103 where the termination is closer to the fireplace than 36" horizontally and 60" vertically. To install the RHS103, Slide the Inner RHS103 36” Min Section over the vent pipe that will connect to the fireplace.
  • Page 17: Section 4: Wiring

    H*38DF-CLCR Corner Gas Fireplace Installation Section 4: Wiring Models Included H38DF-CLn-F HL38 HP38 H38DF-CRn-F HL38 HP38 H38DF-CLL-F HL38 HP38 H38DF-CRL-F HL38 HP38 Receiver 14 Battery Holder w/ Switch REMOTE ON/REMONTE/OFF Orange Green Pilot Receiver 14 Receiver 14 Pin Connector Battery Holder Top View (Not Used) RECEIVER...
  • Page 18: Section 5: Installing The Gas Line

    To check pressures, control valves have a provision to remove  a 1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an  accessible location to isolate the gas supply.
  • Page 19: Section 6: Finishing

    H*38DF-CLCR Corner Gas Fireplace Installation Section 6: Finishing Finishing Around the Fireplace Mantels & Surrounds Combustible mantels and mouldings may be safely installed over the nOTE: National Canadian Gas Association mantel test requirements top and on the front of the fireplace provided that they do not project are for fire hazard prevention to combustible materials.
  • Page 20: Section 7: Installing & Removing The Door

    H*38DF-CLCR Corner Gas Fireplace Installation Section 7: Removing the Door Removing the Front door: The H*38C* Front door is removed in a few simple steps. Follow these Step 5: below to remove the Horizontal access panel, unlatch the door buckles Ensure the tool is firmly and, remove the door.
  • Page 21: Section 8: Installing The Accessories

    H*38DF-CLCR Corner Gas Fireplace Installation Section 8: Installing the Accessories Installing the H38C* Logset The H38C* is supplied with eight (8) fibre logs. The two small bottom Log C logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands.
  • Page 22: Installing The Hp38C* Logset

    H*38DF-CLCR Corner Gas Fireplace Installation Installing the HP38C* Logs and Embers Bottom Logs The HP38C* is supplied with seven (7) fibre logs. The two bottom logs Log F ("A" & B) are mounted on the burner grate as shown in Figure 25a. Top Logs Place logs "C"...
  • Page 23: Installing Firestones In N.g. (Natural Gas) Fireplaces

    These may be spaced at random or in a visual pattern of your Figure 27a. Ensure ONLY one layer of firestones cover the preference in the burner pan. See the Montigo web site for photographs burner and no firestones cover the pilot.
  • Page 24: Section 9: Operation

    H*38DF-CLCR Corner Gas Fireplace Operation Section 9: Start up Sequence Standing (Continuous) Pilot Ignition (SIT NOVA 820) with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 25: Start-Up Sequence With Honeywell Electronic Ignition

    H*38DF-CLCR Corner Gas Fireplace Operation SIT Proflame Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A.
  • Page 26: Start-Up Sequence Sit-Proflame Electronic Ignition

    H*38DF-CLCR Corner Gas Fireplace Operation Honeywell Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A.
  • Page 27: Maintenance

    H*38DF-CLCR Corner Gas Fireplace Maintenance Lighting Instructions Hi-Lo Burner Adjustment: (SIT nova 820). See pages 24 - 26 The H*38C* is equipped with an adjustable burner, allowing you to raise or lower the flames. To adjust the flames, locate the black knob marked General 'Hi-Lo', in the centre of the gas control valve (See Figure 28).
  • Page 28: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Replacement Parts MODEL# H38C* HP38C*I...
  • Page 29: Appendix

    H*38DF-CLCR Corner Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches 12 inches 12 inches clearance to top of doors or operable windows clearance to sides or bottom of door or operable windows 9 inches 12 inches...
  • Page 30: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 31: State Of Massachusetts

    H*38DF-CLCR Corner Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to nFPA-54, Chapter 10 (1) Revise nFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by adding the following additional requirements:...
  • Page 32 H38DF CLCR Corner Gas Fireplace Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0213 - 040512.1...

This manual is also suitable for:

Hl38df-clcrHp38df-clcr

Table of Contents