Section 1: Installation Overview And Product Dimensions; The H36 Pv Fireplace; Fireplace Dimensions; Clearances - Montigo H36PVN Installation & Maintenance Manual

Power vent flush face fireplace
Table of Contents

Advertisement

Please review the Pre-Installation Checklist on Page 4
for general information on preparing for a successful
installation of your fireplace.
The H-Series H36PVN & fireplace
The H36PVN fireplaces may be installed in any location that
maintains proper clearances to air conditioning ducts, electrical
wiring and plumbing . Safety, as well as efficiency of operation,
must be considered when selecting the fireplace location . Try
to select a location that does not interfere with room traffic,
has adequate ventilation, and offers an accessible pathway for
Power Vent installation .
The fireplace dimensions are shown below:
1"
8 3/4"
2"
5 ¾"
Access
Panel
Nailing
Flange
4"
10"
41 ¼"
Flexible Incoming
Gas Connection
¾"
Left
Side View
XG0649 - 031511
Installation
1"
32"
8 3/4"
8"
Top View
23"
5"
C L
Top View
2"
5 ¾"
46"
Nailing
2"
Flange
41 ¼"
¾"
31 ½"
Front View
Nailing
38 ½"
Flange
Front View
XW2022
Figure 1. Fireplace dimensions.
Section 1: Installation Overview and Product Dimensions

Clearances

To ensure the H-Series H36PVN Fireplaces operate safely, all
models must maintain the following clearances .
Clearances to Combustibles
Model#
32"
H36PVN
8"
*Note: Finishing hardwood, laminate flooring, or tile may be placed
directly in front of fireplace, however Montigo waives responsibility for
23"
5"
discoloration of flooring materials . Ability to withstand heat should be
C L
discussed with the flooring manufacturer . If carpet is to laid there must
be a 12" clearance or hearth between the front of the fireplace and the
start of the carpet .
46"
2"
9"
23"
9"
31 ½"
Nailing
38 ½"
Flange
Blk
Wht
Wall Switch
LVT Connection
WARNING
Right
Side View
The H36PVN & H36PVL are power vented
fireplace systems. Under no circumstances can
these model(s) be installed without a power vent
module.
For regular Horizontal vent installation use 5"/8"
model EDVWSPV58 with the rough-in kit,
EDVWSPV58F for the
For regular Vertical vent installation use 5"/8"
model EDVRSPV58 with the rough-in kit, EPVF58
for the H36PVN & H36PVL.
H36PVN Power Vent Indoor Gas Fireplace
Floor
Top
Sides
Back
(under)
8"
0"
1"
23"
Blk
Wht
Power Vent
Wall Switch
Main Incoming A/C
Communication
LVT Connection
Power Connection
Harness Port
Right
Access Panel
Side View
Main Incoming A/C
Power Connection
Floor
(front)*
0"
0"
Power Vent
Communication
Harness Port
Access Panel
Page 5