Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248 XG0211 151126...
H*38DF PRC Panorama Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Instruction Manual Contents Section 9: Installing the Accessories Installing the H38PR* Logset Safety Alerts Operation...
HP38DFPRCN-F 34,000 HP38DFPRCL-F 32,000 Warranty Information : (See Appendix B) The Montigo warranty will be voided by, and Montigo disclaims any responsibility for the following actions: CAUTION ► Modification of the fireplace and/or components including Direct-Vent assembly or glass doors.
Should it be impossible to meet the venting requirements laid Before You Start: out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and ...
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: Section 1: Installation Overview and Product Dimensions Please review the Pre-Installation Checklist on Page 4 for general wiring and plumbing. Safety, as well as efficiency of operation, information on preparing for a successful installation of your should be considered when selecting the fireplace location.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: Section 2: Framing Frame in the enclosure for the unit with framing materials. The Top Vent framed opening for the assembled fireplace is 40 3/4" wide, x Ceiling level 44" high x 24 1/2" deep, see Figure 2 Non-Combustible materials.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: Nailing Flange Extension Clearances The 4" nailing flange extension is shipped attached to the top edge When installing a shelf over the top of the fireplaces, the following of the fireplace, see Figure 1. guidelines must be adhered to: For Rear Vent applications, the minimum clearance is 1"...
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3: Venting Montigo supplies a variety of direct venting and termination outlet, as shown in Figure 8. options. The direct vent termination location MUST be selected 3. Install the (removed) Rear flue cover and gasket material, to such that it is the highest point in the venting assembly.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT TERMINATION (PVTK-1) PVTK1 Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted. Section 3-2-1: VENTING LAYOUT Support ring Selection of components and details of venting lay out should Support plate...
Page 11
H*38DF PRC Panorama Indoor Gas Fireplace Installation PVTK1 Termination Storm Collar Support plate 32’ M a. x Support ring 12” Max. Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend). Note: Images are shown without screens for clarity purposes. However, your fireplace should not be operated without proper installation of screens.
H*38DF PRC Panorama Indoor Gas Fireplace Installation 4). Installation of termination from inside structure Section 3-3: INSTALLING A WALL MOUNTED DIRECT VENT A Termination with a MOSR Frame is installed from the inside of TERMINATION the structure. These are commonly used in high-rise construction. This section applies to installations where the direct vent termi- nation will be wall mounted.
If your installation does not fall with- 42” in the venting graph parameters, Unacceptable vent run please contact a local Montigo within shaded area. dealer for Power Venting options. Figure 12. H38PR* or HL38PR* Top Vent Venting Graph for wall mounted terminations.
Page 14
18 ” If your installation does not fall with in the venting graph parameters, Exterior please contact a local Montigo Wall dealer for Power Venting options. Hearth Figure 13b. H38PR*, HL38PR*, or HP3PR* Top Vented, wall mounted Figure 13.
Page 15
If your installation does not fall with- in the venting graph parameters, collar to the wall flange of the termination. Plot on the Venting please contact a local Montigo Graph Figure 14 or 14a with an 'X'. dealer for Power Venting options.
Page 16
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: 46” Max. Flex or Rigid Note: Images are shown without screens for clarity purposes. Section However, your fireplace should not be operated without proper 26” installation of screens. Min. 59” Min. 12” Max.
PRF-12 (7/12 - 12/12 pt.) any possible hot spots. I - Heat Shield RHS101 Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater J - Heat Guard MTKOG flexibility of installation and absorption of movement.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. Installing a Wall Mounted RHS8 Heat shield The RHS101 Heat shield MUST be used where the RHS8 Termination The RHS8 Heat shield CANNOT be used when the Termination is (Figure 16 and 16a) CANNOT be used.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 4: Wiring Models H38DFPRCN-F HL38DFPRCN-F HPDFPRCN-F H38DFPRCL-F HL38DFPRCL-F HP38DFPRCL-F BATTERY PACK 1.5V AA type 1.5V AA type SPARK GREEN 1.5V AA type WHITE BLACK 1.5V AA type BLACK SENSOR To PPO MAIN ON/OFF SWITCH BLUE 885 PROFLAME...
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: CPI [Continuous Pilot Ignition] / IPI [Intermittent Pilot Installing the CPI Jumper Cable Ignition] Jumper Cable Installation (only available for SIT 1). Access the controller (refer to the installation and Electronic Ignition Systems) maintenance manual for your model).
1/8” N.PT. plug to be fitted with a hose barb. An inspection of the explosion relief flappers and door Montigo requires a service shut off valve be located in an MUST be made prior to lighting the fireplace. A faulty ...
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 6: Finishing Section: Mantels & Surrounds NOTE: National Canadian Gas Association mantel test requirements Finishing Around the Fireplace are for fire hazard prevention to combustible materials. New technology, to meet consumer and government demands for the Combustible mantels and mouldings may be safely installed over wise use of energy, has prompted us to manufacture many models the top and on the front of the fireplace provided that they do not...
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: Section 7: Screen Installation and Removal Left Side Detail Upper Screen Removing Removing / Attaching Screens: Studs Upper Screen The Safet Stud Catch To Remove t Simply gra To Remove Screens: outer corne with your t finger and Grasp each top outer corner of the screen with your...
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section 8: Installing & Removing the Door Step 3: Release the Door Buckles Removing the door: The H*38PR* doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch Hand-hold Door Latch Slot the door buckles and, remove the door.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: Removing the Door: Step 8: Grasp the Door on either side, usually midway and lift upward, lift the door carefully up and away from the front of the fireplace. See Figures 26g. Place the Door aside in a safe place while maintenance and / or cleaning is being performed.
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: Section 9: Installing the Accessories Installing the H38PR* Logset The H38PR* is supplied with eight (8) fibre logs. The two small Log C bottom logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands.
Page 27
H*38DF PRC Panorama Indoor Gas Fireplace Installation Section: Installing the HP38PR* Logs and Embers Log E Bottom Logs The HP38PR* is supplied with seven (7) fibre logs. The two bottom logs ("A" & "B") are mounted on the burner grate as shown in Figure 28a.
Page 28
The H*38PR* has the option of installing the cultured rocks which mimic real stone. These may be spaced at random or in a visual pattern of your preference in the burner tray. See the Montigo web site for photographs and ideas.
H*38DF PRC Panorama Indoor Gas Fireplace Lighting Instruction Updates Lighting Instruction Updates Lighting Instruction Updates Lighting Instruction Updates Operation Operation Replace the warning label with danger label in the Replace the warning label with danger label in the Replace the warning label with danger label in the Replace the warning label with danger label in the For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition...
H*38DF PRC Panorama Indoor Gas Fireplace Operation Section: SIT Proflame 2 Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 6. Turn fireplace "ON" using wall switch or remote control. 2. Remove the lower Horizontal access panel. 7.
H*38DF PRC Panorama Indoor Gas Fireplace Operation Section: Honeywell Electronic Ignition Lighting Instructions: 1. STOP! Read the safety information above on this label. 7. Replace the lower Horizontal access panel. 2. Lift out the lower Horizontal access panel. 8. If the fireplace does not operate, follow the instructions "To Turn Off Gas To Appliance"...
H*38DF PRC Panorama Indoor Gas Fireplace Operation Section: Remote Operation The Proflame 2 System consists of the following elements: Blue Back lit LCD display 1. Pilot Assembly 2. Proflame Gas Valve. On/Off Key 3. Proflame 2 Control Module Thermostat Key 4.
Page 33
H*38DF PRC Panorama Indoor Gas Fireplace Operation Section: Temperature indication Display Initializing the System for the first time 1. Set master override switch to off position. With the system in the "Off" position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on 2.
Page 34
H*38DF PRC Panorama Indoor Gas Fireplace Operation Section: Remote-Flame Control Room Thermostat (Remote Control ....... Operation) When you turn on the fireplace it starts on high. The proflame 2 has six (6) flame levels. Each time you press the Down Arrow The Remote Control can operate as a room thermostat.
Page 35
H*38DF PRC Panorama Indoor Gas Fireplace Operation Section: Disabling Thermostat Fan Speed Control Some jurisdictions and bedroom installations require the The fireplace is equipped with optional hot air circulating fans. thermostat to be disabled. The speed of the fans can be controlled by the Proflame system. The fan speed can be adjusted through six (6) speeds.
Page 36
Note, some jurisdictions do no permit the number of changes to the room thermostat set point, etc. use of continuous pilot system. Check local codes or contact your Montigo dealer. Remote Control When the Remote Control batteries are low, a Battery Icon will With the system in "off"...
H*38DF PRC Panorama Indoor Gas Fireplace Maintenance Section: Maintenance Lighting Instructions See pages 29 to 31. General Have the fireplace and installation inspected yearly. CAUTION! The inspection must include, but is not limited to, the following: Fireplace gas control must be in the “OFF” position and pilot ...
If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 38 XG0211 - 151126...
NG Gas Valve RGC1006 LP Gas Valve RGC1005 NG Pilot RPA020 LP Pilot RPA021 RDTH38PR01 NG Burner RDTH38PR02 RDTH38PR01 RDTH38PR03 Contact Local Montigo Dealer LP Burner Thermocouple RTC182 RSCH38CL2 NAME DATE Descripti Thermopile RPG001 DIMENSIONS ARE IN INCHES TOLERANCES: 12/01/2014...
H*38DF PRC Panorama Indoor Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches clearance to sides or bottom of door or operable windows 9 inches...
The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
H*38DF PRC Panorama Indoor Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
Need help?
Do you have a question about the H38DF PRC and is the answer not in the manual?
Questions and answers