Installation of the LDVPV58 power vent module:
1 .
The linear power vent can be installed to existing stud
construction or directly to cement wall or roof . The LDVPV58
must maintain the clearance to combustibles as shown in Figure
9a . The required service access panel must be framed at 28"
X 18" . To enclose the service access panel, (at less than 2") a
minimum 30% free air must be supplied at all times .
2 .
Plug the power cord into the available slot in the linear power
vent .
3 .
Secure all venting joints with at least three screws and ensure
that the joints are properly sealed by applying high temperature
silicone .
16 1/2
34 7/8
Access Cover
Top View
Figure 9 . LDVPV58 Power Vent overall dimensions.
Framing Dimensions
12 9/64"
5 MIN
Must be left clear on both
ends of Power Vent for
adequate ventilation.
Figure 9a .
LDVPV58 Power Vent framing dimensions.
XG0649 - 031511
Installation
20 3/16"
11
33
2
Side View
1
181/2
5 MIN
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
TWO PLACE DECIMAL
THREE PLACE DECIMAL
ALL BENDS ARE ASSUMED
TO BE 90
OTHERWISE.
Access Cover
2 MIN
Figure 9b .
LDVPV58 Power Vent framing dimensions.
Recessed Termination Installation (VLWB-8) Refer to Appendix A -
Termination locations
8
Figure 10.
Linear Power Vent recessed Termination.
NOTE:
DRAWN BY
1/32"
The H36PVN requires a specific volume of atmospheric interchange
.015"
CHECKED BY
.005"
to operate properly and efficiently
MATERIAL
UNLESS NOTED
„ The fireplace requires a MIN 80in/sq . air movement to function .
FINISH
The grille must also be able to shed water, not allowing any
moisture to enter the unit .
H36PVN Power Vent Indoor Gas Fireplace
Vent
Louvres
5
5
5
MIN
MIN
The VLWB-8 termination is
designed to be installed flush
with the exterior of the building .
This recessed design uses 5"/8"
vent and allows the installation to
be clean and flush so it does not
interfere or have an impact with
your architectural design .
ISOMETRIC VIEW
TERMINATION, VERTICAL MOUNT, 5/8", 12" X 20" BOX
NAME
DATE
LF
7/29/2010
SIZE DWG. NO.
A
304 S.S.T.
SCALE
NTS
1/2
MIN
18 1/8"
8
(NTS)
VLWB-8
SHEET 1 O
WEIGHT:
Page 19

Advertisement

Table of Contents
loading

Table of Contents