Installing The External Roof Mounted Power Vent Module - Montigo H36PVN Installation & Maintenance Manual

Power vent flush face fireplace
Table of Contents

Advertisement

H36PVN Power Vent Indoor Gas Fireplace
Step 5.
Install the Power Vent, Roof-top Stainless steel cover over the
Installed Rough-in Kit . (You can see the Electrical harness connector
in the top right corner) .
Electrical Harness
from Power Vent
Figure 5e.
Step 6.
Install the Power Vent Module Power / communication harness .
Hold the Power Vent in close proximity of the assembled Chase,
(with stainless steel cover attached) and plug in the Power Vent
communication / Power Cord . (Note the direction and orientation of
the plug socket) . (See Figure 5e & Figure 5f)
Install Power Vent Module
with Power / Communication
Harness
CAUTION!
Figure 5g. (Installation of Power Vent Module)
Vent terminations can be very hot. The termination is to be installed higher than 7 feet above a public walkw
Do not obstruct, or attempt to conceal, the vent termination. These actions will a ect the operation of the
Step 7.
In heavy snow areas, take extra care to prevent snow buildup from obstructing the vent termination.
Install the Power Vent Module . Place the Power Vent Module
over the stainless steel cover flange and vent pipe, aligning the
Power Vent into final position . Ensure the Harness is placed down
in the Rough-in box when placing the Power Vent Module into place .
The Power Vent Module will sit flush with the stainless steel cover
if installed correctly .
Page 12
Installation
Figure 5f.
Vertical Roof Top
Power Vent
Vertical Roof Top
Power Vent Rough-
in Kit
Figure 5h. (Installed Power Vent Module)
Step 8.
Install (3) three stainless steel fasteners around Power Vent
Module @120 degrees (penetrating through the inner stainless steel
vent cover)
XW2026
Stainless Steel
Fasteners
CAUTION
■ Vent terminations can be very hot. The
termination is to be installed higher than 7 feet
above a public walkway.
■ Do not obstruct, or attempt to conceal, the vent
termination. These actions will affect the operation
of the fireplace, and may be hazardous.
■ In heavy snow areas, take extra care to
prevent snow buildup from obstructing the vent
termination.
XG0649 - 031511