WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
— Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a qualified
installer, service agency or the gas fitter.
DANGER
A barrier designed to reduce the risk of burns from the
hot viewing glass is provided with this appliance and
must be installed for the protection of children and
other at-risk individuals.
®
C
US
HOT GLASS WILL
CAUSE BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
Installation & Maintenance Manual
Divine H36PV
POWER VENT FLUSH FACE FIREPLACE
Installer: Leave this manual with the appliance.
Consumer: Retain this manual for suture reference.
Installation and service must be performed by a qualified installer,
service agency or the gas fitter.
Read and understand this manual. Improper installation, adjustment,
alteration, service or maintenance can cause serious injury, property
damage or even death. For assistance or additional information
consult a qualified installer, service agency or the gas supplier.
Some materials used in the manufacturing process of this product can
expose you to Benzene which is known in the State of California to
cause cancer and birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov
NOTICE
CAUTION
DANGER
WARNING
XG0649 - 080921

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Divine H36PV and is the answer not in the manual?

Questions and answers

Summary of Contents for Montigo Divine H36PV

  • Page 1 Installation & Maintenance Manual DISCONTINUED ITEM THIS ITEM HAS BEEN DISCONTINUED AND IS NO LONGER IN PRODUCTION. PLEASE CONTACT YOUR LOCAL MONTIGO DEALER REGARDING MAINTENANCE AND SPARE PARTS AVAILABILITY. Divine H36PV POWER VENT FLUSH FACE FIREPLACE NOTICE ® Installer: Leave this manual with the appliance.
  • Page 2: Table Of Contents

    H36PVN Power Vent Indoor Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for future reference and maintenance. Table of Contents Table of Contents Instruction Manual Contents Safety Alerts Introduction Section A: Before You Start...
  • Page 3: Safety Alerts

    Introduction Introduction Warranty and Installation Information: (See Appendix B) The Montigo warranty will be voided by, and Montigo disclaims Congratulations on your purchase of a Montigo Fireplace. any responsibility for, the following actions: ► Modification of the fireplace and/or components including With over 30 years of experience, Montigo is committed to Direct-Vent assembly or glass doors.
  • Page 4: Section A: Before You Start

    Vent" for details. Installation and repairs should be done by an authorized gas fireplace service technician. ■ Montigo supplies 20' of low voltage wire, which can be The appliance should be inspected before use and at least annually by a professional. More spliced to any length.
  • Page 5: Rating Plate Sample

    H36PVN Power Vent Indoor Gas Fireplace Installation Installation Rating Plate Sample Figure A: Rating Plate for IPI eletronic ignition Page 5 XG0649 - 080921...
  • Page 6: Section 1: Installation Overview And Product Dimensions

    *Note: Finishing hardwood, laminate flooring, or tile may be placed The fireplace dimensions are shown below: directly in front of fireplace, however Montigo waives responsibility for discoloration of flooring materials. Ability to withstand heat should be discussed with the flooring manufacturer. If carpet is to laid there must be a 12"...
  • Page 7: Section 2: Framing

    THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CAN Non-combustible Header (supplied by montigo), install to allow 15½” of Non-combustible cement board to fasten above the glass of the unit and Non-combustible header.
  • Page 8 Step 1. As shown in Figure 3; Use Non combustible Cement board, at sides of unit (see figure 2a on page 6) using sheet metal screws. supplied by Montigo, screw to Non-combustible Header and 2 x 4's Non-combustible Cement Board (supplied by montigo).
  • Page 9: Section 3: Finishing

    8” 10” from top of unit 9” 8” Non-combustible 7” Header (supplied by 6” Montigo @ 6½”) 5” 4” Non-Combustible Cement Board 3” (supplied by Montigo) 2” 1” 12” 11” 10” 9” 8” 7” 6” 5” 4” 3” 2” 1”...
  • Page 10: Section 4: Installing The Power Vent

    H36PVN Power Vent Indoor Gas Fireplace Installation Installation Section 4: Installing the Power Vent Venting Installation Downward Vertical Venting External Power Vent System must be used with a gas fireplace that is Downward venting installations are only possible with gas fireplaces equipped with electronic ignition system. When installing the venting, equipped with electronic ignition system.
  • Page 11: Venting Components

    Place the springs, supplied with the pipe kit, between the outer and „ inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe „ 3.950 connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 12 H36PVN Power Vent Indoor Gas Fireplace Installation Installation ROUGH IN KIT EDVRSPVF47 ROUGH IN KIT !IMPORTANT! MAINTAIN AT LEAST 18.000 2.00" CLEARANCE TO COMBUSTIBLES ALL AROUND THE COLLAR Step 4: Unscrew 6 screws securing the control cable cover 3.950 and remove it. 6.918 FRAMING DIMENSIONS (NTS)
  • Page 13 H36PVN Power Vent Indoor Gas Fireplace 20" uct a chase box around the netration with the dimensions Installation Installation wn here. Cable " Step #4 Step #2 Place termination head over chase and fasten with 4 screws on the vertical sides of the base plate. Step 8: Push the molex Install the vent pipe female end up 2"...
  • Page 14: Venting Layout - Wall Mounted Vertical Exterior Power Vent

    H36PVN Power Vent Indoor Gas Fireplace Installation Installation Venting Installation Downward Vertical Venting External Power Vent System must be used with a gas fireplace that is Downward venting installations are only possible with gas fireplaces equipped with electronic ignition system. When installing the venting, equipped with electronic ignition system.
  • Page 15 12 5/16" 9 11/16" inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final pipe „ connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 16 H36PVN Power Vent Indoor Gas Fireplace Installation Installation Installing the Power Vent Strain Relief Selecting A Termination Location Power Vent Conduit 12 ‰ Before installing the termination, ensure that the proper air flow restrictor is installed as shown, and Strain Relief check to ensure the planned termination location is acceptable.
  • Page 17 Rough-in box when placing the Power Vent. (Secure the Power Vent in Place with the supplied hardware). Montigo will not be held responsible for any water damage that may occur from not installing the equipment as specified by this document.
  • Page 18 WARNING CAUTION All venting material must be Montigo flex pipe, with as few joints ■ Vent terminations can be very hot. The termination is to be installed higher than 7 feet as possible. All joints use MVA vent splice. Montigo will not be above a public walkway.
  • Page 19 „ outer and inner pipes to keep the pipes separate and avoid any possible hot spots. Montigo recommends the use of a flex section for the final „ pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 20 H36PVN Power Vent Indoor Gas Fireplace Installation Installation 13 5/16" Installation of the LDVPV58 power vent module: The linear power vent can be installed to existing stud construction or directly to cement wall or roof. The LDVPV58 must maintain the clearance to combustibles as shown in Figure Vent 9a.
  • Page 21: Section 5: Wiring

    H36PVN Power Vent Indoor Gas Fireplace Installation Installation Section 5: Wiring The Fireplace A/C power and Power Vent harness's must be installed Step 2. Locate all the Power vent connections & ports, Figure 12b. before completing the installation of the H36PVN Fireplace. These connections are made from the RH-Side of the fireplace, Figure 12 through Figure 12f.
  • Page 22 H36PVN Power Vent Indoor Gas Fireplace Installation Installation Step 5. Route the Power Vent Comunication conduit into the cover as shown, and connect to the communication Port, Figure 12d. Installing The Remote Switch The H36PVN's Remote LVT (Low Voltage) Switch conduit is located Note on the RH Side of the fireplace.
  • Page 23 H36PVN Power Vent Indoor Gas Fireplace Installation Installation WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Connect to DC wall transformer. See Figure 13a. Figure 13.
  • Page 24: Conduit & Wiring Clearances

    H36PVN Power Vent Indoor Gas Fireplace Installation Installation ON-OFF CIRCUIT Connect to receptacle. See Jumpered Figure 13. CPI/IPI Switch (not used) Figure 13a. H36PVN, SIT IPI Wiring Schemmatic Conduit & Wiring clearances Connect the wiring to the linear power vent as outlined in the previ- ous section, and connect the wiring to the fireplace as outlined in the H36PVN schematic, figure 13.
  • Page 25: Section 6: Installing The Gas Line

    To check pressures, control valves have a provision to remove „ a 1/8” N.PT. plug to be fitted with a hose barb. Montigo requires a service shut off valve be located in an „ accessible location to isolate the gas supply.
  • Page 26: Section 7: Installing & Removing The Screen And Door

    H36PVN Power Vent Indoor Gas Fireplace Installation Installation Section 7: Installing & Removing the Screen and Door Step 3. Remove the two (2) screen / glass door retainer slides by pulling firmly with your fingers. Removing the doors: The screen and door are removed in a few simple steps. Step 1.
  • Page 27 H36PVN Power Vent Indoor Gas Fireplace Installation Installation Step 5. Hold the Glass Removal Tools firmly, Lift the door upward, Step 10. Hook the bottom tabs of the screen into the slots in the into the top door frame, Figure 17. Then pull the bottom of the glass screen / glass door retainer slides.
  • Page 28: Section 8: Installing The Log Set

    Figure 18a & 18e. Log A Figure 18. Packaged LogSet as supplied from Montigo. Log A Retaining Clip Figure 18d. Location of Log 'A'. Log A back-pan Move Log ‘A’...
  • Page 29 H36PVN Power Vent Indoor Gas Fireplace Installation Installation Step 5. Position the Bottom Right Log 'B' and place Right end in the Step 8. Place Front Left Log 'E', with the Knots pointing in the sheet metal cradle (located at the far right of the Log Grate), Figure, directions shown, Figure, 18k.
  • Page 30: Section 9: Operation - Start Up Sequence

    H36PVN Power Vent Indoor Gas Fireplace Operation Operation Section 9: Operation - Start up Sequence For Your Safety - READ BEFORE LIGHTING: with American Flame Electronic Ignition WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 31: Section 10: Maintenance

    H36PVN Power Vent Indoor Gas Fireplace Maintenance Maintenance Section 10: Maintenance Removing the Log Grate: Step 1 & 2. Figure 20. (Pilot mounting machine screws). The H36PVN is supplied with a log Grate that is fastened directly to the base of the Fireplace. To remove the Grate, to perform certain Maintenance functions, follow the steps described below: Step 3 &...
  • Page 32: Removing The Stand-Off Panels

    H36PVN Power Vent Indoor Gas Fireplace Maintenance Maintenance Removing the Stand-off Panels: Removing the Access Panel: The H36PVN is supplied two (2) two Stand-off Panels (RH & LH) that The H36PVN is supplied one (1) one interior access Panel (RH-side) hold the firebox refractory Lining in place.
  • Page 33: General

    H36PVN Power Vent Indoor Gas Fireplace Maintenance Maintenance Removing the Interior firebox Access Panel: General Have the fireplace and installation inspected yearly. The The H36PVN is supplied one (1) one interior access Panel (LH-side „ inspection must include, but is not limited to, the following: firebox) that contains the Gas valve, and electronics.
  • Page 34: Troubleshooting (Only To Be Done By Qualified Service Personnel)

    Ensure the vent or the exhaust termination are not back ON automatically after sometime blocked by debris. Adjust the Fan speed higher and restart the fireplace. If failure persists, contact Montigo for support. If your fireplace still does not operate correctly, consult your dealer or the manufacturer.
  • Page 35: Appendix A: Power Vent Locations

    H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix Appendix A: Power Vent Locations Vertical Detail Horizontal Detail A = clearance to the termination frame above grade, veranda, porch, deck, clearance above paved sidewalk or a paved driveway located on public †...
  • Page 36 H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix Appendix A: Power Vent Locations EDVRSPV58 Vertical Power Vent Detail EDVWSPV58 Horizontal Power Vent Detail Wall 30”Min. “R” Eaves / Overhang Wall 30”Min. “ F” & “G” Wall 30”Min “R” Top View 30”...
  • Page 37 H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix Page 37 XG0649 - 080921...
  • Page 38 (collectively referred to herein as "The Companies"), warrants the If the components of the appliance covered by this warranty Montigo gas appliance (referred to herein as 'the appliance') to are found to be defective within the time frame stated (see The...
  • Page 39: Appendix B: Warranty

    In the event the installing dealer is unavailable, contact your nearest authorized Montigo dealer (www.Montigo.com) or contact Montigo direct at techsupport@ montigo.com. Ensure you have your sales receipt and the model and serial number of your appliance. DO NOT ATTEMPT TO DO ANY SERVICE WORK YOURSELF If you cannot locate the installing dealer, or nearest dealer/ distributor, you must notify The Companies in writing.
  • Page 40: Appendix C: State Of Massachusetts

    H36PVN Power Vent Indoor Gas Fireplace Appendix Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 41 Appendix Indoor fireplace in protected outdoor applications This fireplace may be installed into outdoor locations provided they are suitably protected from direct water impingement. However, all installation clearances in the appliance manual must be observed. Framing, Clearances to Combustibles, Mantel Heights, Facing Requirements, Venting Installation, etc. Use supplied Safety Screen. Dimension "A"...
  • Page 42 Installation & Maintenance Manual H36PV H36PV Power Vented Residential Gas Fireplace Power Vented Residential Gas Fireplace XG0649 - 080921...

Table of Contents