Linear Power Vent - Vertical Termination
Venting Installation
Maximum
Vent Run
Vent Run**
80 Feet
** from fireplace to in-line power vent
Maximum allowable vent run must be reduced by ten feet (10'-0") for
every additional 90° elbow added . Figure's 8 and 8a .
Example A. Vertical Mounting with Vertical Termination
2'-0 "
MIN
90deg
Elbow
2'-0 "
90deg
MIN
Elbow
Figure 8 . Vertical Vent for the Linear Power Venter
Example B. Vertical Mounting with Vertical Termination
2'-0 "
MIN
90deg
Elbow
90deg
Elbow
Vertical
Flex Pipe
Figure 8a . VerticaI Linear Power Vent with Vertical Vent Run
Page 18
Installation
Minimum
Max. #
Elbows
2 Feet
3
Termination
Vertical
Flex Pipe
90deg
Elbow
Vertical Installed
Linear PowerV ent
LDVPV58
90deg
Elbow
Termination
90deg
Elbow
Vertical Installed
Linear Power Vent
LDVPV58
90deg
Elbow

Venting Components

The following venting components and associated Montigo
part numbers are available for the LDVPV58:
A - Termination
DVPV58
B - Power Vent
LDVPV58
C - Control Module
RHSIT05
D - Flex Sections
PFL-1 (12" Section)
PFL-2 (24" Section)
PFL-3 (36" Section)
PFL-4 (48" Section)
E - Rigid Sections
PEXT - 1 (12" m/f Section)
PXT-20 (20" section)
PEXT - 2 (24" m/f Section)
PEXT - 3 (36" m/f Section)
PEXT - 4 (48" m/f Section)
F - Elbows
PEL-90MM (m/m 90° Elbow)
PEL-90FF (f/f 90° Elbow)
PEL-90FM (f/m 90° Elbow)
PEL-45FM (f/m 45° Elbow)
G - Power Cord
EPVH10 -10 foot power cord and harness
Harnesses:
EPVH20 -20 foot power cord and harness
EPVH30 -30 foot power cord and harness
EPVH40 -40 foot power cord and harness
EPVH50 -50 foot power cord and harness
EPVH60 -60 foot power cord and harness
EPVH70 -70 foot power cord and harness
EPVH80 -80 foot power cord and harness
EPVH90 -90 foot power cord and harness
EPVH100 -100 foot power cord and harness
Connection and installation of the vent components
should adhere to the following guidelines:
Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue .
Ensure the pipe ends male to female slide in a minimum
of 1 1/2" of overlap .
Ensure all runs are supported with a minimum of 3 supports
per 10' of venting .
When hanging/ supporting venting, ensure that 1" clearance
is maintained on all sides to any combustible material .
Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports .
Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots .
Montigo recommends the use of a flex section for the final
pipe connected directly to the fireplace offering greater
flexibility of installation and absorption of movement .
All exterior joints in venting should be sealed with high
heat silicone RV230 .