Venting Components - Montigo H36PVN Installation & Maintenance Manual

Power vent flush face fireplace
Table of Contents

Advertisement

H36PVN Power Vent Indoor Gas Fireplace

Venting Components

The following venting components and associated Montigo part
numbers are available for the EDVWSPV58:
A - Termination
EDVRSPV58
B - Rough-in Frame
EDVRSPV58F
C - Flex Sections
PLF-1 (12" Section)
PLF-2 (24" Section)
PFL-3 (36" Section)
PFL 4 (48" Section)
D - Rigid Sections
PEXT-1 (12" m/f Section)
PXT-20 (20" Section)
PEXT-2 (24" m/f Section)
PEXT-3 (36" m/f Section)
PEXT-4 (48" m/f Section)
E - Elbows
PEL-90MM (m/m 90º Elbow
PEL-90FF (f/f 90º Elbow
PEL-90FM (f/m 90º Elbow)
PEL-45FM (f/m 90º Elbow)
F - Power Cord
EPVH10-10 foot power cord & harness
Harnesses
EPVH20-20 foot power cord & harness
EPVH30-30 foot power cord & harness
EPVH40-40 foot power cord & harness
EPVH50-50 foot power cord & harness
EPVH60-60 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH70-70 foot power cord & harness
EPVH80-80 foot power cord & harness
EPVH90-90 foot power cord & harness
EPVH100-100 foot power cord & harness
Connection and installation of the vent components should
adhere to the following guidelines:
■ Connect all vent sections using a minimum of three sheet
metal screws on the outer pipe flue .
■ Ensure the pipe ends male to female slide in a minimum
of 1 1/2" of overlap .
■ Ensure all runs are supported with a minimum of 3 supports
per 10' of venting .
■ When hanging/ supporting venting, ensure that 1" clearance
is maintained on all sides to any combustible material .
■ Ensure when cutting sections of rigid pipe to maintain
integrity of internal supports .
■ Place the springs, supplied with the pipe kit, between the
outer and inner pipes to keep the pipes separate and avoid
any possible hot spots .
■ Montigo recommends the use of a flex section for the final
pipe connected directly to the fireplace offering greater
flexibility of installation and absorption of movement .
■ All exterior joints in venting should be sealed with high heat
silicone RV230 .
Page 14
Installation
Installation of the EDVWSPV58 external wall mounted power vent
module.
Refer to Appendix A - Power Vent locations, to ensure the planned
Vertical Power vent location is acceptable .
The EDVWSPV58 Power Vent dimensions:
11 1/16"
11 1/16"
9.0
5
The EPVF58 Rough-in Frame dimensions:
EPVF58 DIMS (2).pdf 1 3/7/2011 9:16:30 AM
14 1/4"
4 9/16"
11 1/16"
9 3/4"
10 9/16"
14 1/16"
12 5/16"
12 1/8"
1 1/2"
8
9 11/16"
10 9/16"
5
9.0
9 11/16"
4
ISOMETRIC VIEW
XG0649 - 031511