Step 1. Construct a Vertical Chase for the termination
opening to meet the following requirements:
Opening Size must be:
14½"
Figure 4. Construction, Rough-in framing.
Step 2. Install the Vent pipe female end up, and 2" to 3"
MAX. from the top of the Constructed Chase. Also, at this
point install the Electrical harness, (EPVH-(10-100) that will
communicate with the Power Vent Module.
2" to 3" Max.
Vent Chase
Figure 4a. Installation, Vertical Vent pipe. (female.end.top.end).
XW2024
XG0770 - 020911
Installation
14 1/2" x 14 1/2" x 18" Min. height.
14½"
18"
Electrical Harness
with connection
Vent Pipe
WARNING
All venting material must be sealed with high heat
silicone sealant RV230. All venting material to be
Montigo flex pipe, with as few joints as possible.
All joints use MVA vent splice, sealed thoroughly
with silicone. Montigo will not be held responsible
for any water damage that may occur from not
installing the equipment as specified by this
document.
R-Series R320-R420 Indoor Gas Fireplace
Step 3. Install the Power Vent Rough-in Kit. Pull wire
harness through the supplied hole in the bottom corner
of the rough-in box, and snap into the slot provided, (See
figure 4b.inset).
Electrical Harness
Connerctor Location
Figure 4b. Installation of Rough-in Kit
Step 4. Install fasteners around perimeter of Rough-in Kit.
(Holes.supplied.for.ease.of.installation)
Figure 4c. (Fasten Rough-in Kit to framing)
Figure 4d. (Installed Stainless steel cover)
Power Vent
Rough-in Kit
Electrical
Harness
Install Fasteners around
perimeter of Rough-in Kit