3–60
"C" Group: Intelligent Terminal Functions
Func.
Name/
Code
Description
C038
Low current indication
output mode select
C039
Low current indication detection level
Low current threshold, used for intelligent output [LOC]
C040
Overload signal output mode ON
Choose when the overload
signal is enabled
C041
Overload level setting 1
C042
Frequency arrival setting for acceleration
Sets the frequency arrival setting threshold for the output frequency during acceleration
C043
Arrival frequency setting for deceleration
Sets the frequency arrival setting threshold for the output frequency during deceleration
C044
PID deviation level setting
Sets the PID loop error threshold |SP - PV| (absolute value) to trigger intelligent output [OD]
C045
Frequency arrival setting for acceleration (2)
C046
Frequency arrival setting for deceleration (2)
C052
Maximum PID feedback (PV) data
C053
Minimum PID feedback (PV) data
C055
Over-torque (forward-driving) level setting
Threshold for intelligent output terminal [OTQ], quadrant I
C056
Over-torque (reverse regenerating) level
setting
Threshold for intelligent output terminal [OTQ], quadrant II
C057
Over-torque (reverse driving) level setting
Threshold for intelligent output terminal [OTQ], quadrant III
C058
Over-torque (forward regenerating) level
setting
Threshold for intelligent output terminal [OTQ], quadrant IV
C061
Electronic thermal warning level setting
Sets the threshold for intelligent output [THM]
C062
Alarm code output
Allows binary alarm codes to
be output to intelligent
terminals
C063
Zero speed detection level
C064
Heatsink overheat warning level
Alarm temperature threshold for heatsink in inverter
Keypad
Range and Settings
SRW
OPE
00
ON
Output during acceleration/deceleration and
constant speed operation
0 1
CRT
Output only during constant speed
0.0 to 1.80 x rated inverter current
00
During accel / decel / constant speed
0 1
During constant speed only
CRT
0.00 x rated current to 1.80 x rated current
(A)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.00 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.0 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 99.99, 100.0 to 400.0 (Hz)
0.0 to 100.0 (%)
0.0 to 100.0 (%)
0. to 180. (%)
0. to 180. (%)
0. to 180. (%)
0. to 180. (%)
0. to 100. (%)
00
OFF
Disable
0 1
3BIT
Enable – 3-bit code
02
4BIT
Enable – 4-bit code
0.00 to 99.99 / 100.0 (Hz)
0. to 200.0 (°C)
Defaults
Run
Mode
FEF2
FUF2
FF2
Edit
FE2
FU2
F2
Lo Hi
(EU)
(USA)
(Jpn)
✘ ✔
01
01
01
✘ ✔
Rated current x 1.0
✘ ✔
✘ ✔
01
01
01
✘ ✔
Rated current for
inverter
✘ ✔
0.00
0.00
0.00
✘ ✔
0.00
0.00
0.00
✘ ✔
3.0
3.0
3.0
✘ ✔
0.00
0.00
0.00
✘ ✔
0.00
0.00
0.00
✘ ✔
0.00
0.00
0.00
✘ ✔
100.0
100.0
100.0
✘ ✔
100.
100.
100.
✘ ✔
100.
100.
100.
✘ ✔
100.
100.
100.
✘ ✔
100.
100.
100.
✘ ✔
80.
80.
80.
✘ ✔
00
00
00
✘ ✔
0.00
0.00
0.00
✘ ✔
120
120
120
✘ ✔

Advertisement