Hitachi SJ7002 Series Instruction Manual page 342

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

B–58
ModBus Data Listing
Func. Code
B088
— Restart mode after FRS
(Reserved)
B090
— Dynamic braking usage
ratio
B091
— Stop mode selection
B092
— Cooling fan control
(Reserved)
(Reserved)
B095
— Dynamic braking control
B096
— Dynamic braking activa-
tion level
(Reserved)
B098
— Thermistor for thermal
protection control
B099
— Thermal protection level
setting
B100
— Free-setting V/f freq. (1)
B101
— Free-setting V/f voltage (1)
B102
— Free-setting V/f freq. (2)
B103
— Free-setting V/f voltage (2)
B104
— Free-setting V/f freq. (3)
B105
— Free-setting V/f voltage (3)
B106
— Free-setting V/f freq. (4)
B107
— Free-setting V/f voltage (4)
B108
— Free-setting V/f freq. (5)
B109
— Free-setting V/f voltage (5)
B110
— Free-setting V/f freq. (6)
B111
— Free-setting V/f voltage (6)
B112
— Free-setting V/f freq. (7)
B113
— Free-setting V/f voltage (7)
Holding Registers, "B" Group Fine Tuning Functions
Name
R/W
R/W
00 . Restart from 0Hz
01 . Restart from frequency
detected from actual speed
of motor
02 . Restart from active matching
frequency
R/W
0.0 to 100.0 (%)
Set = 0.0 to disable dynamic
braking
R/W
00 . DEC (decelerate and stop)
01 . FRS (free run to stop)
R/W
00 . Fan always ON
01 . Fan ON during RUN,
OFF during STOP
R/W
00 . Disable
01 . Enable during RUN only
02 . Enable always
R/W
330 to 380 (V) (200V class),
660 to 760 (V) (400V class)
R/W
00 . Disable
01 . Enable-PTC thermistor
02 . Enable-NTC thermistor
R/W
Thermistor resistance threshold
at which trip occurs
R/W
0. to Free-setting V/f freq. (2)
R/W
0.0 to 800.0 (V)
R/W
0. to Free-setting V/f freq. (3)
R/W
0.0 to 800.0 (V)
R/W
0. to Free-setting V/f freq. (4)
R/W
0.0 to 800.0 (V)
R/W
0. to Free-setting V/f freq. (5)
R/W
0.0 to 800.0 (V)
R/W
0. to Free-setting V/f freq. (6)
R/W
0.0 to 800.0 (V)
R/W
0. to Free-setting V/f freq. (7)
R/W
0.0 to 800.0 (V)
R/W
0. to 400.0 (V)
R/W
0.0 to 800.0 (V)
Description
Register
hex
135Bh
135Ch
135Dh
135Eh
135Fh
1360h
1361h
1362h
1363h
1364h
1365h
1366h
1367h
1368h
1369h
136Ah
136Bh
136Ch
136Dh
136Eh
136Fh
1370h
1371h
1372h
1373h
1374h
Network Data
Range
Res.
dec.
04955
0, 1, 2
04956
04957
0 to 1000
0.1 %
04958
0, 1
04959
0, 1
04960
04961
04962
0, 1, 2
04963
330 to 380
1 V
660 to 760
04964
04965
0, 1, 2
1 Ω
04966
0 to 9999
04967
0 to V/f 2
1 Hz
04968
0 to 8000
0.1 V
04969
0 to V/f 3
1 Hz
04970
0 to 8000
0.1 V
04971
0 to V/f 4
1 Hz
04972
0 to 8000
0.1 V
04973
0 to V/f 5
1 Hz
04974
0 to 8000
0.1 V
04975
0 to V/f 6
1 Hz
04976
0 to 8000
0.1 V
04977
0 to V/f 7
1 Hz
04978
0 to 8000
0.1 V
04979
0 to V/f 8
1 Hz
04980
0 to 8000
0.1 V

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents