Hitachi SJ7002 Series Instruction Manual page 338

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

B–54
ModBus Data Listing
Func. Code
B313
— Electronic thermal charac-
teristic, 3rd motor
(Reserved)
B015
— Free setting, electronic
thermal frequency (1)
B016
— Free setting, electronic
thermal current (1)
B017
— Free setting, electronic
thermal frequency (2)
B018
— Free setting, electronic
thermal current (2)
B019
— Free setting, electronic
thermal frequency (3)
B020
— Free setting, electronic
thermal current (3)
B021
— Overload restriction opera-
tion mode
B022
— Overload restriction setting
B023
— Deceleration rate at
overload restriction
B024
— Overload restriction opera-
tion mode (2)
B025
— Overload restriction setting
(2)
B026
— Deceleration rate at
overload restriction (2)
B027
— Overcurrent suppression
enable
B028
— Current limit for active
frequency-matching restart
Holding Registers, "B" Group Fine Tuning Functions
Name
R/W
R/W
00 . Reduced torque
01 . Constant torque
02 . Free-setting
R/W
Data point coordinates for Hz
axis (horizontal) in the free-form
curve
R/W
Data point coordinates for
Ampere axis (vertical) in the
free-form curve
R/W
Data point coordinates for Hz
axis (horizontal) in the free-form
curve
R/W
Data point coordinates for
Ampere axis (vertical) in the
free-form curve
R/W
Data point coordinates for Hz
axis (horizontal) in the free-form
curve
R/W
Data point coordinates for
Ampere axis (vertical) in the
free-form curve
R/W
00 . Disable
01 . Enable for acceleration
and constant speed
02 . Enable for constant
speed only
03 . Enable for accel, decel,
and constant speed
R/W
(0.20 x rated current) to (1.80 x
rated current) (A)
R/W
0.10 to 30.00 (seconds)
R/W
00 . Disable
01 . Enable for acceleration
and constant speed
02 . Enable for constant
speed only
03 . Enable for accel, decel,
and constant speed
R/W
(0.20 x rated current) to (1.80 x
rated current) (A)
R/W
0.10 to 30.00 (seconds)
R/W
00 . Disable
01 . Enable
R/W
(0.20 x rated current) to (1.80 x
rated current) (A)
Description
Register
hex
330Dh
330Eh
to
3506h
1310h
1311h
1312h
1313h
1314h
1315h
1316h
1317h
1318h
1319h
131Ah
131Bh
131Ch
131Dh
Network Data
Range
Res.
dec.
13069
0, 1, 2
13070
to
13574
04880
0 to 400
1 Hz
04881
0 to rated
0.1 A
current
04882
0 to 400
1 Hz
04883
0 to rated
0.1 A
current
04884
0 to 400
1 Hz
04885
0 to rated
0.1 A
current
04886
0 to 3
04887
200 to
0.1 %
2000
04888
10 to 3000
0.1 sec.
04889
0 to 3
04890
200 to
0.1 %
2000
04891
1 to 3000
0.01 sec.
04892
0, 1
04893
200 to
0.1 %
2000