Restore Defaults
1. HBA Parameters<port selection>3. Restore Defaults
From the HBA Parameters Menu, select the Restore Defaults option to reset the
adapter parameters to their default values. For example:
Warning:
1:
2:
Target Persistent Bindings (-p)
2. Adapter Configuration2. Fibre Channel Adapter2. Target Persistent Bindings
From the Fibre Channel Adapter Configuration menu, select the Target
Persistent Bindings option. From the port menu, select a port to open the LUN
List Menu with option to view LUN information and persistent names. For
example:
Fibre Channel Adapter Configuration
HBA Model QLA2342 SN: GFC0718P57753
1: Port
2: Port
Target Persistent Binding Menu
=======================================================
HBA
SN
HBA Model
HBA Desc.
FW Version
WWPN
WWNN
Link
SN0054667-00 B
Please update the HBA parameters with extreme care.
Incorrectly updating the HBA parameters may render the HBA inoperable.
If you currently have boot device information set up in the HBA
parameters, updating the HBA Parameters from a file
will preserve that information.
Do you want to proceed with the operation?
Yes
No
(p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
Please Enter Selection: 1
1: WWPN: 21-00-00-1B-32-17-F9-C4 Online
2: WWPN: 21-01-00-1B-32-37-F9-C4 Loop Down
(p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
Please Enter Selection: 1
: 0 Port: 1
: P07467
: QLA2342
: QLA2342/QLA2342L (PCI to FC dual channel)
: N/A
: 21-01-00-E0-8B-37-8B-00
: 20-01-00-E0-8B-37-8B-00
: Online