Qlogic 2400 Series User Manual

Qlogic 2400 Series User Manual

Qconvergeconsole cli
Hide thumbs Also See for 2400 Series:
Table of Contents

Advertisement

Quick Links

User's Guide
QConvergeConsole CLI
2400, 2500, 2600, 3200, 8100, 8200, 8300 Series
SN0054667-00 G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2400 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Qlogic 2400 Series

  • Page 1 User’s Guide QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series SN0054667-00 G...
  • Page 2 QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification.
  • Page 3: Table Of Contents

    Supported QLogic Adapters ........
  • Page 4 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Command Line Uninstall....... Uninstalling QConvergeConsole CLI in a Linux Environment .
  • Page 5 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -iset (Display Configured Port Settings) ..... . . -link ........... 5-10 -minidump .
  • Page 6 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Fibre Channel Noninteractive Commands Displaying System Information (Command Line Options -g, -z, and -tp) . . . Host Information (Command Line Option -g)....Host Configuration (Command Line Option -z) .
  • Page 7 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -sp ........... . 6-36 -t (FC Target/LUN Information) .
  • Page 8 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -dtlia (Login and Persist a Discovered Target) ....7-10 -dtrem (Remove Discovered Target) ......7-10 -dtrema (Remove Discovered Target) .
  • Page 9 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -rwt (Read Write Buffer Test—iSCSI) ......7-23 -save (Save Host Configuration) .
  • Page 10 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series NIC Interactive Commands Adapter Information ......... . . CNA Adapter Information (-icna) .
  • Page 11 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Display HBA Parameters (-c)......10-9 Configure HBA Parameters (-n) .
  • Page 12 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Start Diagnostics Test ....... . . 10-44 Read Write Buffer Test (-kr) .
  • Page 13 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series CNA FCoE Information (-cna) ......11-11 NIC .
  • Page 14 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Firmware Preload Table Update (-u) ......11-103 Firmware Serdes Table Update (-sp) .
  • Page 15 What Is NPAR? ..........QLogic Adapters That Support NPAR ......
  • Page 16 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Default Settings ......... . Configuration Options .
  • Page 17 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series NPAR Wake on LAN (WoL) and PXE Boot Support ......Using DCBX and NPAR for Bandwidth Settings .
  • Page 18 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series xviii SN0054667-00 G...
  • Page 19: Preface

    This preface explains the QConvergeConsole CLI help system, describes the typographic conventions used in this guide, lists related documents, specifies the intended audience, refers you to the QLogic license agreements, and provides technical support and contact information. The remainder of the user’s guide is organized into the following chapters:...
  • Page 20: What Is In The Help System

    This guide is for system administrators who are responsible for installing, configuring, and managing QLogic adapters using QConvergeConsole CLI. Related Materials For additional help installing or using QConvergeConsole CLI, refer to the following related documents posted on the QLogic Web site http://driverdownloads.qlogic.com:  QConvergeConsole CLI Readme...
  • Page 21: Documentation Conventions

    Press CTRL+P.  Press the UP ARROW key.  Text in italics indicates terms, emphasis, variables, or document titles. For example:  For a complete listing of license agreements, refer to the QLogic Software End User License Agreement. SN0054667-00 G...
  • Page 22 Preface Documentation Conventions  What are shortcut keys?  To enter the date type mm/dd/yyyy (where mm is the month, dd is the day, and yyyy is the year).  Topic titles between quotation marks identify related topics either within this manual or in the online help, which is also referred to as the help system throughout this document.
  • Page 23: License Agreements

    Preface License Agreements License Agreements Refer to the QLogic Software End User License Agreement for a complete listing of all license agreements affecting this product. Technical Support Customers should contact their authorized maintenance provider for technical support of their QLogic products. QLogic-direct customers may contact QLogic Technical Support;...
  • Page 24: Training

    Training QLogic Global Training maintains a Web site at www.qlogictraining.com offering online and instructor-led training for all QLogic products. In addition, sales and technical professionals may obtain Associate and Specialist-level certifications to qualify for additional benefits from QLogic. Contact Information QLogic Technical Support for products under warranty is available during local standard working hours excluding QLogic Observed Holidays.
  • Page 25: System Requirements

    System Requirements QConvergeConsole CLI is a management utility that centralizes management and configuration of QLogic adapters within the entire network (LAN and SAN). For optimum performance, QConvergeConsole CLI requires the hardware, software, and operating systems listed in this chapter: ...
  • Page 26: Software Requirements

    Administrative privileges to perform management functions   QLogic adapter drivers for your operating system NOTE Refer to the QLogic Web site for QLogic adapter drivers and agents: http://driverdownloads.qlogic.com. Operating System Requirements QConvergeConsole CLI runs on the following platforms: ®...
  • Page 27 1–System Requirements Operating System Requirements NOTE For an up-to-date list of supported operating system versions, refer to the QConvergeConsole CLI Readme, which can be downloaded where QConvergeConsole CLI is posted on the QLogic Web site: http://driverdownloads.qlogic.com. SN0054667-00 G...
  • Page 28: Supported Qlogic Adapters

    2400/2500/2600 Series Fibre Channel Adapters  3200 Series Intelligent Ethernet Adapters  8100/8200/8300 Series Converged Network Adapters NOTE For information about QLogic adapters, refer to the QLogic Web site at http://www.qlogic.com/Products/adapters. To determine support for OEM-branded adapters, please contact your OEM. SN0054667-00 G...
  • Page 29: Installing And Uninstalling Qconvergeconsole Cli

    To download QConvergeConsole CLI from the QLogic Web site: Go to the QLogic Downloads and Documentation page: http://driverdownloads.qlogic.com Under QLogic Products, type the QLogic model name in the search box. Alternatively, you can click Guided Search to obtain assistance in locating the QConvergeConsole CLI version to download.
  • Page 30: Installing Qconvergeconsole Cli

    <version> is the version number of the QConvergeConsole CLI. The default directory for the QConvergeConsole CLI utility is: Program Files\QLogic Corporation\QConvergeConsoleCLI If you want to install QConvergeConsole CLI in a different directory, enter it in the command line. For example: QConvergeConsoleCLI-<version>_win.msi installdir=<directory>...
  • Page 31: Quiet Or Silent Windows Installation

    2–Installing and Uninstalling QConvergeConsole CLI Installing QConvergeConsole CLI in a Linux Environment Quiet or Silent Windows Installation A quiet or silent installation installs using defaults. This mode requires no user intervention. Issue the following command for a quiet (silent) installation: Windows 64-bit: msiexec.exe /qn /package QConvergeConsoleCLI-<version>-win_x64.msi Windows 32-bit:...
  • Page 32: Installation Using Package Files (Solaris 10 Or 11)

    Select package(s) you wish to process (or 'all' to process all packages). (default: all) [?,??,q]: Processing package instance <QCCLI> from </qlogic/QConvergeConsoleCLI-1.0.03-23-sol8-sol11-x86.pkg> QLogic QConvergeConsole CLI (CNA Configuration Utility)(i386) 1.00.03 Build 23 (Solaris 8-11) QLogic Corporation ## Executing checkinstall script. ## Processing package information.
  • Page 33: Installation Using P5P Files (Solaris 11 Only)

    Solaris 11 SPARC or Solaris 11 x86 environment using p5p files: # export PKGREPO=/pkgrepo # pkgrepo create $PKGREPO # pkgrecv -s /qlogic/QConvergeConsoleCLI-1.0.03-23-solaris-i386.p5p -d $PKGREPO qaucli Processing packages for publisher qlogic ... Retrieving and evaluating 1 package(s)... PROCESS ITEMS GET (MB)
  • Page 34: Uninstalling Qconvergeconsole Cli

    Command Line Uninstall Start Menu Uninstall To uninstall from the Windows Start menu: Go to Start. Point to All Programs, point to QLogic Management Suite, and then click Uninstall QConvergeConsole CLI. Control Panel Uninstall To uninstall from the Control Panel: Go to Start, and then click Control Panel.
  • Page 35: Uninstalling Qconvergeconsole Cli In A Linux Environment

    QConvergeConsole CLI: G13457-T9x6275M2N1# pkgrm QCCLI The following package is currently installed: QCCLI QLogic QConvergeConsole CLI (CNA Configuration Utility) (i386) 1.00.03 Build 23 (Solaris 8-11) Do you want to remove this package? [y,n,?,q] y ## Removing installed package instance <QCCLI>...
  • Page 36: Uninstalling A P5P Installation (Solaris 11 Only)

    2–Installing and Uninstalling QConvergeConsole CLI Uninstalling QConvergeConsole CLI in a Solaris Environment Do you want to continue with the removal of this package [y,n,?,q] y ## Verifying package <QCCLI> dependencies in global zone ## Processing package information. ## Executing preremove script. ## Removing pathnames in class <none>...
  • Page 37 2–Installing and Uninstalling QConvergeConsole CLI Uninstalling QConvergeConsole CLI in a Solaris Environment ## Executing postremove script. ## Updating system information. Removal of <QCCLI> was successful. SN0054667-00 G...
  • Page 38 2–Installing and Uninstalling QConvergeConsole CLI Uninstalling QConvergeConsole CLI in a Solaris Environment 2-10 SN0054667-00 G...
  • Page 39: Getting Started

    Getting Started QConvergeConsole CLI manages iSCSI, Ethernet, and Fibre Channel functions on QLogic Fibre Channel Adapters, Intelligent Ethernet Adapters, and Converged Network Adapters. This chapter describes how to start the QConvergeConsole CLI using the noninteractive mode (command line interface) and the interactive mode (menu-driven interface), as well as how to get help.
  • Page 40: Using Interactive Mode

    Using Interactive Mode Interactive mode is a menu-driven interface that manages QLogic Ethernet Adapters, QLogic Fibre Channel Adapters, and all functions of QLogic Converged Network Adapters, including NIC, Fibre Channel, iSCSI and NPAR. The interface for each adapter type is described in its own separate chapter: Chapter 9 NIC Interactive Commands ...
  • Page 41: Starting Qconvergeconsole Cli In Solaris

    3–Getting Started Main Menu Starting QConvergeConsole CLI in Solaris To start QConvergeConsole CLI in interactive mode in Solaris, issue the following command: #qaucli Main Menu When you start QConvergeConsole CLI in interactive mode, the Main Menu appears as follows: Main Menu Adapter Information Adapter Configuration Adapter Updates...
  • Page 42: Getting Help

    [ -nic | -fc | -iscsi ] [options] DESCRIPTION: qaucli is a unified command line application, which can be used to manage all QLogic adapter models. The overall option (i.e: -pr <protocol> allows user to start the application with a specific protocol type (NIC/iSCSI/FC)
  • Page 43 3–Getting Started Getting Help by default. OPTIONS: Menu Mode qaucli - Start in interactive mode qaucli -pr nic [options] - Launch application with NIC discovery only qaucli -pr iscsi [options] - Launch application with iSCSI discovery only qaucli -pr fc [options] - Launch application with FC discovery only Command Line Mode qaucli [options]...
  • Page 44 "When the following command is executed: qaucli.exe -pr all -h, the help is printed below .\qaucli.exe -pr all -h QConvergeConsole Version 1.0.1 (Build 28) Copyright (C) 2012 QLogic Corporation Build Type: Release Build Date: Jan 26 2012 17:58:07 Usage: qaucli [options] The following is a simplified help for extension of non-interactive commands for all protocols (NIC/FC/iSCSI).
  • Page 45 3–Getting Started Getting Help NOTE: mac,wwnn and wwpn switches are exclusive wwpn=[11-22-33-44-55-66-77-88] //limit update to device with WWN NOTE: mac,wwnn and wwpn switches are exclusive fwdump=fwdump_file_name // NOT implemented yet comment=[on|true|yes|y|1] // inserts comments into xml output // on mac of the device // and other info if available discoverall=[on|true|yes|y|1] // discover all adapters;...
  • Page 46 3–Getting Started Getting Help SN0054667-00 G...
  • Page 47: General Noninteractive Commands

    To view the general help for all protocols, issue the -pr all -h command as follows: .\qaucli.exe -pr all -h QConvergeConsole Version 1.0.1 (Build 28) Copyright (C) 2012 QLogic Corporation Build Type: Release Build Date: Jan 26 2012 17:58:07 Usage: qaucli [options] The following is a simplified help for extension of non-interactive commands for all protocols (NIC/FC/iSCSI).
  • Page 48 4–General Noninteractive Commands Viewing General Help where switch is one of the following command line switches: -help // Display help info // Same as -help // Same as -help // Same as -help // List errors codes for -pr all switches -svmtool [svm-options] // SVM FW Update Tool...
  • Page 49: Viewing All Inventory

    4–General Noninteractive Commands Viewing All Inventory // same as discoverall=[on|true|yes|y|1] -suppress_version_match // suppress match check // for version of flash file // and version in svmtool.cfg -supvermatch // same as -suppress_version_match Example 1 - Display vesion only qaucli -pr all -svmtool mode=version Example 2 - Update FW from file and produce xml output to stdout and to a file;...
  • Page 50: Viewing All Flash Image Versions

    4–General Noninteractive Commands Viewing All Flash Image Versions <Device vendorID="1077" subVendorID="1077" deviceID="8020" subDeviceID="0210" bus="0" device="0" function="1" display="QLogic QME8242 Adapter" > <!-- SerialNumber="AFE1020C03193" Protocol="nic" ISIP="19" --> <!-- MAC: 00:0e:1e:04:88:59 WWPN: NA WWNN: NA --> <Application componentType="FRMW" version="04.09.46" display="QLogic QME8242 Adapter"/> </Device>...
  • Page 51: Viewing All Matching Flash Image Versions

    4–General Noninteractive Commands Viewing All Matching Flash Image Versions Supported ChipIDs: B0, C0 Found 13 entries for supported card types in file: p3p10929.bin 00 - venid=1077 subvenid=ffff devid=0001 subdevid=ffff 01 - venid=1077 subvenid=1077 devid=8020 subdevid=0233 02 - venid=1077 subvenid=1077 devid=8021 subdevid=0234 03 - venid=1077 subvenid=1077 devid=8022 subdevid=0235 04 - venid=1077 subvenid=1077 devid=8020 subdevid=0210 05 - venid=1077 subvenid=1077 devid=8021 subdevid=0211...
  • Page 52 12 - venid=1077 subvenid=1077 devid=8022 subdevid=0230 Searching for match between image file and detected devices ... ============================================================================== Adapter: SerialNumber=3U702950ET ProtocolType=nic/fcoe/iscsi IsNPARAdapter=0 ============================================================================== NO MATCH Device: vendorID="1077" subVendorID="103c" deviceID="8020" subDeviceID="3346" (ln:-1;chipMatch:1) bus="0" device="0" function="0" ISP=19 (CNA NIC) display="QLogic CN1000Q Adapter" SN0054667-00 G...
  • Page 53 4–General Noninteractive Commands Viewing All Matching Flash Image Versions ChipVersion="B0" versionFlashInBinFile="" MAC="78:e7:d1:f4:e8:48" WWPN="NA" WWNN="NA" NO MATCH Device: vendorID="103c" subVendorID="103c" deviceID="8021" subDeviceID="3348" (ln:-1;chipMatch:1) bus="0" device="0" function="0" ISP=20 (CNA FCoE) display="QLogic CN1000Q Adapter" ChipVersion="B0" versionFlashInBinFile="" MAC="78:e7:d1:f4:e8:4b" WWPN="21-00-78-E7-D1-F4-E8-4B" WWNN="20-00-78-E7-D1-F4-E8-4B" NO MATCH Device: vendorID="1077" subVendorID="103c" deviceID="8022"...
  • Page 54 4–General Noninteractive Commands Viewing All Matching Flash Image Versions MAC="00:0e:1e:04:88:5b" WWPN="NA" WWNN="NA" MATCH Device: vendorID="1077" subVendorID="1077" deviceID="8022" subDeviceID="0212" (ln:06;chipMatch:1) bus="0" device="0" function="0" ISP=21 (CNA iSCSI) display="QLogic QME8242 Adapter" ChipVersion="B0" versionFlashInBinFile="" MAC="00:0e:1e:04:88:5d" WWPN="NA" WWNN="NA" MATCH Device: vendorID="1077" subVendorID="1077" deviceID="8021" subDeviceID="0211" (ln:05;chipMatch:1) bus="0"...
  • Page 55 4–General Noninteractive Commands Viewing All Matching Flash Image Versions NO MATCH Device: vendorID="1077" subVendorID="1077" deviceID="8000" subDeviceID="0179" (ln:-1;chipMatch:0) bus="0" device="0" function="0" ISP=17 (CNA NIC) display="QLogic QLE8142 Adapter" ChipVersion="A0" versionFlashInBinFile="" MAC="00:c0:dd:0a:b4:78" WWPN="NA" WWNN="NA" NO MATCH Device: vendorID="1077" subVendorID="1077" deviceID="8001" subDeviceID="0179" (ln:-1;chipMatch:0) bus="0" device="0" function="0" ISP=18 (CNA FCoE) display="QLogic QLE8142 Adapter"...
  • Page 56: Viewing All Flash Updates

    <!-- Content of "svmtool.cfg" --> <!-- vendorID=1077 subVendorID=1077 deviceID=8020 subDeviceID=0210 version=1.9.29 (line:00) --> <SVMExecution lang="en"> <Device vendorID="1077" subVendorID="1077" deviceID="8020" subDeviceID="0210" bus="0" device="0" function="1" display="QLogic QME8242 Adapter" > <!-- SerialNumber="AFE1020C03193" Protocol="nic" ISIP="19" --> <!-- MAC: 00:0e:1e:04:88:59 WWPN: NA WWNN: NA --> <Application componentType="FRMW" version="01.09.29"...
  • Page 57 4–General Noninteractive Commands Viewing All Flash Updates <Device vendorID="1077" subVendorID="1077" deviceID="8020" subDeviceID="0210" bus="0" device="0" function="0" display="QLogic QME8242 Adapter" > <!-- SerialNumber="AFE1020C03193" Protocol="nic" ISIP="19" --> <!-- MAC: 00:0e:1e:04:88:58 WWPN: NA WWNN: NA --> <Application componentType="FRMW" version="01.09.29" display="QLogic QME8242 Adapter" > <Package version="01.09.29"/>...
  • Page 58 4–General Noninteractive Commands Viewing All Flash Updates 4-12 SN0054667-00 G...
  • Page 59: Nic Noninteractive Commands

    NIC Noninteractive Commands This chapter describes the noninteractive NIC command format and parameters of QConvergeConsole CLI. NOTE To view the help, issue the -h command. Command Format NIC noninteractive commands have the following format: qaucli -pr nic [optional parameters] <command option> [positional parameters] qaucli -pr nic -switch [optional cna_port_instance] Where switch is one of the following:...
  • Page 60 5–NIC Noninteractive Commands Command Format  -n (Change Port Alias Name [NIC Configuration]) -nh (Adapter Alias [NIC Configuration])   -pinfo (CNA Port Information)  -ping   -sreset (Reset NIC Statistics)  -statport (Display NIC Port Statistics)  -sunreset (Undo Reset NIC Statistics) ...
  • Page 61: Command Summary

    5–NIC Noninteractive Commands Command Summary Command Summary This section lists each command line option in alphabetic order, and provides a description of each and example of most. NOTE A parenthetical phrase after a command indicates the equivalent interactive menu option. For example, -c indicates (NIC Port Setting Configuration) that the -c command has an equivalent NIC Port Setting Configuration...
  • Page 62: Extloopback

    5–NIC Noninteractive Commands To view the adapter configuration, issue the -ch command as follows: > qaucli -pr nic -ch [cna_port_inst] For example: > qaucli -pr nic -ch 1 === Displaying CNA config info for 1. CNA Port Index === CNA_Alias CNA X54 To generate Extensible Markup Language (XML) discovery output, issue the -d command as follows:...
  • Page 63 5–NIC Noninteractive Commands -flashsupport Where is one of the following options: <option> option: To discover the Converged Network Adapters and generate an XML report, issue the following command: > qaucli -pr nic -flashsupport -d <flash_file> [out_xml_file] Where <flash_file> is the name of the Flash file that will be used to update the adapter and out_xml_file is the name of the output XML file.
  • Page 64 5–NIC Noninteractive Commands -flashsupport Where <flash_file> is the name of the Flash file that will be used to update the adapter. option: To set the adapter interface, issue the following command: > qaucli -pr nic -flashsupport -i --interface <interface_id> Where interface_id is an interface ID value displayed by the -vi switch.
  • Page 65: H (Help)

    > qaucli -pr nic -h The QConvergeConsole CLI help file contains a condensed version of the contents of this chapter. To view a list of all QLogic adapter ports detected, issue the -i command as follows: > qaucli -pr nic -i [cna_port_inst] For example: >...
  • Page 66: Icna (Cna Adapter)

    5–NIC Noninteractive Commands -icna (CNA Adapter) 1. CNA: 1 CNA Port: 1 CNA Model: QLE8142 PortID: 0 Mac Phys. Address: 00:c0:dd:12:0f:f4 Loc. Mac: 00:c0:dd:12:0f:f4 CNA Serial Number: AFC0916A07152 MPI FW Version: 1.35.00 Adapter Alias: None Port Alias: CNA X54 IPv4 Address: 192.168.204.201 IPv6 Addresses: fe80::2c0:ddff:fe12:ff4 -icna...
  • Page 67: Intloopback

    5–NIC Noninteractive Commands -intloopback -intloopback NOTE An external loopback test requires the installation of a loopback plug in the port SFP. To configure loopback test parameters before you run the test, issue the intloopback command as follows: > qaucli -pr nic -intloopback <cna_port_inst> <tests_num> <on_error>...
  • Page 68: Link

    5–NIC Noninteractive Commands -link NOTE Linux does not support the Receive_Side_Scaling_Enable option. -link To view the status of the physical link, including the port speed, issue the -link command as follows: > qaucli -pr nic -link [cna_port_inst] For example: > qaucli -pr nic -link 1 === Physical Link Status for 1.
  • Page 69: Nh (Adapter Alias [Nic Configuration])

    : 1514 Interface Scope ID : 91 Interface Speed : 10 Gbps Interface Description : QLogic 10Gb PCI Ethernet Adapter - Network Load Balancing Filter Device === Port Information for 2. CNA Port Index === . . . SN0054667-00 G 5-11...
  • Page 70: Ping

    5–NIC Noninteractive Commands -ping -ping To run a ping diagnostic, issue the -ping command as follows: > qaucli -pr nic -ping <cna_port_inst> <hostname_or_IPv4> [<count> <packet size> <timeout_ms> <TTL>] Where the default parameter values are as follows: count = 5 packet size = 525 timeout_ms = 1000 TTL = 30 For example:...
  • Page 71: Statport (Display Nic Port Statistics)

    5–NIC Noninteractive Commands -statport (Display NIC Port Statistics) -statport (Display NIC Port Statistics) To view the Ethernet port statistics, issue the -statport command as follows: > qaucli -pr nic -statport [cna_port_inst] For example: > qaucli -pr nic -statport 1 Port statistics for 1. CNA Port Index txPkts : 12989 txOctets...
  • Page 72: Sunreset (Undo Reset Nic Statistics)

    5–NIC Noninteractive Commands -sunreset (Undo Reset NIC Statistics) txMgmtPkts : 7921 rxCBFCPauseFrames0 rxCBFCPauseFrames1 rxCBFCPauseFrames2 rxCBFCPauseFrames3 rxCBFCPauseFrames4 rxCBFCPauseFrames5 rxCBFCPauseFrames6 rxCBFCPauseFrames7 rxFCoEPkts rxMgmtPkts : 7912 rxPktsPriority0 rxPktsPriority1 rxPktsPriority2 rxPktsPriority3 : 306 rxPktsPriority4 rxPktsPriority5 rxPktsPriority6 rxPktsPriority7 txPktsPriority0 txPktsPriority1 txPktsPriority2 txPktsPriority3 : 306 txPktsPriority4 txPktsPriority5 txPktsPriority6 txPktsPriority7...
  • Page 73: Team_Allowcnasin8023Adteam (Lacp Override)

    To delete a team, issue the -teamdel command as follows: > qaucli -pr nic -teamdel <team_inst|ALL> For example: > qaucli -pr nic -teamdel 3 About to delete team: 1 (QLogic VT-IM Miniport Driver #2). Please wait ... Successfully deleted team: 1 () -teaminfo...
  • Page 74: Teamlist (Display Teams List)

    Loading: 1. CNA ... Loading: 1. CNA Port index : 1 ... Loading: 1. CNA Port index : 2 ... Team: 1 Team Description: QLogic VT-IM Miniport Driver #2 VLAN ID: None Team Type: Fail Over Team Members: CNA: 1 CNA Port: 1...
  • Page 75: Teamnew_Portspreview

    MAC: 00:c0:dd:0a:b1:a9 Description: QLogic 10Gb PCI Ethernet Adapter #2 - Network Load Balancing Filter Device QLogic 10Gb PCI Ethernet Adapter #2 - Network Load Balancing Filter Device About to create the team. Please wait ... Successfully created team with interface description: QLogic VT-IM Miniport...
  • Page 76: Testflash

    5–NIC Noninteractive Commands -testflash IPv6 Addresses: fe80::2c0:ddff:fe12:ff4 2. CNA: 1 CNA Port: 2 CNA Model: QLE8142 PortID: 1 Mac Phys. Address: 00:c0:dd:12:0f:f6 Loc. Mac: 00:c0:dd:12:0f:f6 CNA Serial Number: AFC0916A07152 MPI FW Version: 1.35.02 Adapter Alias: None Port Alias: None IPv4 Address: 192.168.205.200 IPv6 Addresses: fe80::2c0:ddff:fe12:ff6 -testflash...
  • Page 77: Testlink (Link Test)

    5–NIC Noninteractive Commands -testlink (Link Test) -testlink (Link Test) To test the link, issue the -testlink command as follows: > qaucli -pr nic -testlink [cna_port_inst] -testregister (Register Test) To test the register, issue the -testregister command as follows: > qaucli -pr nic -testregister [cna_port_inst] -trans (Transceiver Monitoring Interface [DMI]) To display transceiver diagnostics monitoring interface (DMI) data, issue the...
  • Page 78: V, -Ver (Display Program Version Information)

    Loading: 1. CNA Port index : 2 ... VLAN List: ListIndex: 1 CNA: 1 CNA Port: VLAN ID: None MAC: 00:c0:dd:0a:b1:a8 Description: QLogic 10Gb PCI Ethernet Adapter - Network Load Balancing Filter Device ListIndex: 2 CNA: 1 CNA Port: VLAN ID: None MAC:...
  • Page 79: Vlanadd_Preview

    120 MAC: 00:c0:dd:0a:b1:a9 Description: QLogic 10Gb PCI Ethernet Adapter #2 User entered ListIndices: ALL User entered VLAN ID: ALL About to remove VLAN ID(s) for ListIndex: 1. (QLogic 10Gb PCI Ethernet Adapter #2) Please wait ... Successfully removed VLAN ID. -vlandel_preview...
  • Page 80: Vlaninfo (Display Vlan Information)

    VLAN List: CNA: 1 CNA Port: VLAN ID: 120 MAC: 00:c0:dd:0a:b1:a9 Description: QLogic VT-IM Miniport Driver #2 -vpd (CNA VPD Information) To display vital product data (VPD) information, issue the -vpd command as follows: > qaucli -pr nic -vpd [cna_port_inst]...
  • Page 81 5–NIC Noninteractive Commands -vtcfgview Accessing file: c:/system_1.cfg Number of Teams: 1 ---------------- type=Fail Over MAC: 00:c0:dd:0a:b4:61 00:c0:dd:0a:b4:60 (VLAN IDs: 555) Number of Ports: 3 ---------------- MAC :00:c0:dd:0a:b4:34 (VLAN IDs: 35) MAC :00:c0:dd:0a:b4:35 (VLAN IDs: 777) MAC :None (VLAN IDs:) Number of VLANS: 3 ---------------- ......
  • Page 82: Vtrestore (Restore Vlan & Teaming Configuration)

    NOTE The -vtrestore command can restore a configuration file produced only by the -vtsave command. Similarly, a configuration that is saved using the QLogic Windows Teaming property pages can be restored only with the Windows Teaming property pages. For example: >qaucli -pr nic -vtrestore c:/system_1.cfg...
  • Page 83 Updating IP properties for all ports ... Please wait ... ListIndex: 1 CNA: 1 CNA Port: VLAN ID: None MAC: 00:c0:dd:0a:b4:60 Description: QLogic 10Gb PCI Ethernet Adapter #3 ListIndex: 2 CNA: 1 CNA Port: VLAN ID: None MAC: 00:c0:dd:0a:b4:61 Description: QLogic 10Gb PCI Ethernet Adapter #4...
  • Page 84: Vtsave (Save Vlan & Teaming Configuration)

     A configuration that is saved with the -vtsave command can be restored only with the -vtrestore command. Similarly, a configuration that is saved using the QLogic Windows Teaming property pages can be restored only with the Windows Teaming property pages.
  • Page 85: Zvt (Display Teams List; Display Vlan List; Display Vlan Information)

    Loading: 2. CNA Port index : 2 ... Refreshing interfaces ... Please wait ... Attempting to save TEAMs and VLANs Configuration. Team: 1 Team Description: QLogic VT-IM Miniport Driver VLAN ID: 555 Team Type: Fail Over Team Members: CNA: 1 CNA Port: 1...
  • Page 86 5–NIC Noninteractive Commands -zvt (Display Teams List; Display VLAN List; Display VLAN Information) Team: 1 Team Description: QLogic VT-IM Miniport Driver VLAN ID: 555 Team Type: Fail Over Team Members: CNA: 1 CNA Port: 1 MAC: 00:c0:dd:0a:b4:60 Description: QLogic 10Gb PCI...
  • Page 87: Fibre Channel Noninteractive Commands

    Fibre Channel Noninteractive Commands This chapter describes the noninteractive Fibre Channel command format and parameters of QConvergeConsole CLI. For a quick reference to informative commands, see Displaying System Information (Command Line Options -g, -z, and -tp) on this page. NOTE To view help, issue the -h command.
  • Page 88: Host Configuration (Command Line Option -Z)

    (online or offline)  Total number of QLogic Fibre Channel Adapters detected NOTE The failover and SAN device management APIs are QLogic-specific libraries required for QConvergeConsole CLI. The versions of these libraries are useful for debugging purposes. Host Configuration (Command Line Option -z) The command line option -z provides a summary for the selected adapter in a single command.
  • Page 89: Host Port Configuration

    6–Fibre Channel Noninteractive Commands Host Port Configuration Host Port Configuration Use these options to show the information for one or all of the adapter ports in the system. The -z option shows the combination of the commands listed in Table 6-1.
  • Page 90 6–Fibre Channel Noninteractive Commands Command Format  -s = Silent mode (see “-s” on page 6-36). For example: # qaucli -pr fc -i all -s -o output.txt  -x = Outputs the results in XML format (see “-x” on page 6-40).
  • Page 91: Command Summary

    6–Fibre Channel Noninteractive Commands Command Summary Command Summary This section lists the command line options in alphabetic order, and provides a description of each. NOTE A parenthetical phrase after a command indicates the equivalent interactive menu option. For example, -c indicates (NIC Port Setting Configuration) that the -addchap command has an equivalent Add a CHAP menu option...
  • Page 92  Due to a hardware and firmware limitation, the -a option is not supported on QLogic 8200 Series Adapters. To view the adapter port’s LED beacon state, issue the following command: # qaucli -pr fc -a (<hba instance> | <hba wwpn>)(view | info) When the adapter’s LED is flashing, the following message appears:...
  • Page 93: B (Flash Update; Save Flash)

    6–Fibre Channel Noninteractive Commands -b (Flash Update; Save Flash) If QConvergeConsole CLI is not in silent mode (see “-s” on page 6-36), one of the following messages appears to indicate the LED’s current state: The LED Flashing for <hba instance> <hba wwpn> has been turned ON The LED Flashing for <hba instance>...
  • Page 94: C (Display Hba Parameters)

    = World wide port name of the adapter -cna (CNA FCoE Information) Use the -cna command to work with QLogic Converged Network Adapters (QLE81xx and QLE82xx). The -cna command line options use the following variables: hba instance = Adapter instance number of a Converged Network Adapter port...
  • Page 95 6–Fibre Channel Noninteractive Commands -cna (CNA FCoE Information) To update the message passing interface (MPI) configuration table on the Converged Network Adapter (81xx only) from a file, issue the following command: qaucli -cna <hba instance>|<hba wwpn> | <all> --updatecfg <mpi file> To save the MPI configuration table on the Converged Network Adapter (81xx only) to a file, issue the following command: qaucli -cna <hba instance>|<hba wwpn>...
  • Page 96: Dm (Transceiver Diagnostics Monitoring Interface [Dmi])

    The -dm option allows you to show general or detailed digital diagnostic monitoring interface for optical transceivers. NOTE This option is supported only for QLogic QLA/QLE/QEM24xx (4Gb) Adapters. Under Solaris, this option is disabled if you are using Linux inbox drivers (SLES 10.0 or RHEL 5.0 or later).
  • Page 97 6–Fibre Channel Noninteractive Commands -e (Boot Devices Configuration) To view the current boot device selection on all adapters: # qaucli -pr fc -e all (view | info) To view the current boot device selection for a specific adapter: # qaucli -pr fc -e (<hba instance> | <hba wwpn>) (view | info) In Solaris SPARC, if the system is running with a csh or tsch shell, include double quotes around the question mark (?).
  • Page 98 6–Fibre Channel Noninteractive Commands -e (Boot Devices Configuration) To set a specific target as the boot device for a specific adapter, issue the following command: # qaucli -pr fc -e (<hba instance> | <hba wwpn>) <target wwnn> <target wwpn> <target id> <lun id> NOTE Because x86 Solaris does not require the target ID, the Solaris command is: # qaucli -pr fc -e (...
  • Page 99 6–Fibre Channel Noninteractive Commands Issue the -ei command to view a list of the Fibre Channel error codes. NOTE The -f option is valid only in noninteractive mode, and cannot be combined with any other options. Only one command line parameter per file is valid.
  • Page 100: Fs (Driver Parameters)

    6–Fibre Channel Noninteractive Commands -fs (Driver Parameters) To show the driver settings, issue the following command: # qaucli -pr fc -fg (<hba instance> | <hba wwpn>) (view | info) Where: hba instance = Adapter number (use the -g command to find) hba wwpn = World wide port name of the adapter (Driver Parameters) To configure the driver settings, issue the following command:...
  • Page 101: Fwdump (Firmware Dump)

    6–Fibre Channel Noninteractive Commands -fwdump (Firmware Dump) The following restrictions apply:  Under Solaris, the driver configuration feature is disabled if you are using the driver from the OS installation CDs (QLC driver). Under Linux, this feature is disabled if you are using the input/output control ...
  • Page 102: H (Help)

    To view help information for an individual command, issue the following command: # qaucli -pr fc <command line parameter> (-h) For example, typing qaucli -pr fc -l -h shows the following: Using config file: G:\Program Files\QLogic Corporation\QConvergeConsoleCLI\qaucli.cfg Installation directory: G:\Program Files\QLogic Corporation\QConvergeConsoleCLI Working dir: G:\Documents and Settings\user1 QLogic FCAPI v1.7.3 Build 38...
  • Page 103: Ha (Adapter Alias [Fcoe Configuration])

    6–Fibre Channel Noninteractive Commands -ha (Adapter Alias [FCoE Configuration]) scli -l <hba instance>|<hba wwpn> Displays all LUNs information of a device attached on an HBA port. scli -l <hba instance>|<hba wwpn> <target wwpn>|<target portid> Displays a specific LUN information of a target device attached on an HBA port. scli -l <hba instance>|<hba wwpn>...
  • Page 104: Kl (Loopback Test)

    6–Fibre Channel Noninteractive Commands -kl (Loopback Test) Where: all = All adapters in the system (default) VPD = Vital Product Data To show general or VPD information for a specific adapter, issue the following command: # qaucli -pr fc -i (<hba instance> | <hba wwpn>) [VPD] To show VPD for all adapter ports in the system, issue the following command: # qaucli -pr fc -i VPD (Loopback Test)
  • Page 105: Kr (Read Write Buffer Test)

    6–Fibre Channel Noninteractive Commands -kr (Read Write Buffer Test) NOTE To stop an active diagnostic test, press ENTER. To use an alternate key to stop tests, modify this line in the sfcli.properties configuration file: Default: node.app.diag.ascii.abortkey=CR Custom: node.app.diag.ascii.abortkey=<stop key> Where <stop key> is any alphabetic character a–z or A–Z (uppercase characters require pressing SHIFT+<stop key>).
  • Page 106: Running A Read/Write Buffer Test

    6–Fibre Channel Noninteractive Commands -kr (Read Write Buffer Test) Where: hba instance = Adapter number (use the -g command to find) hba wwpn = World wide port name of the adapter -ex or -exclude = World wide port name of the target device that is excluded from the read/write test param name = One of the following parameter names: ...
  • Page 107: Running An Adapter Diagnostics Read/Write Buffer Test

    6–Fibre Channel Noninteractive Commands -kr (Read Write Buffer Test) The following examples run 500 read/write buffer tests with a test increment of 10, a data pattern of FFh, and a data size of 8 bytes. The test stops if an error occurs. # qaucli -pr fc -kr <hba instance>...
  • Page 108 6–Fibre Channel Noninteractive Commands -kr (Read Write Buffer Test) Table 6-6 lists the <param name>, <param alias>, and <param value> options. Table 6-6. Diagnostics Parameters Alias Name Value <param Description <param name> <param value> alias> 00, 55, 5A, A5, AA, FF (see Table 6-7) DataPattern...
  • Page 109: L (Fc Target/Lun Information)

    6–Fibre Channel Noninteractive Commands -l (FC Target/LUN Information) Table 6-7. Data Pattern (DP) Test Patterns Binary Binary 00000000 10100101 01010101 10101010 01011010 11111111 If the read/write buffer test fails, the system shows the following information:  Loop or port ID (the loop ID of the adapter when operating in loop mode). Status: ...
  • Page 110: Ls (Display Parameters [Hba Statistics])

    6–Fibre Channel Noninteractive Commands -ls (Display Parameters [HBA Statistics]) To show the LUN information for a specific device for a specific adapter port, issue the following command: # qaucli -pr fc -l (<hba instance> | <hba wwpn>) (<target port id> | <target wwpn>) To show the LUN information for a specific LUN on a specific target device for a specific adapter port instance, issue the following command:...
  • Page 111: M (Selective Luns)

    6–Fibre Channel Noninteractive Commands -m (Selective LUNs) (Selective LUNs) NOTE  If the current driver setting is Bind by Port ID, this option is not available.  Under Solaris, if you use the driver from the OS installation CDs (QLC driver), this feature is disabled.
  • Page 112 6–Fibre Channel Noninteractive Commands -m (Selective LUNs) In Solaris SPARC, include double quotes around the question mark (?) if the system is running with a csh or tsch shell. For example: # qaucli -pr fc -m <HBA> "?" QConvergeConsole CLI shows the adapter’s enabled LUN list in the following format: <target wwnn>...
  • Page 113: N (Configure Hba Parameters)

    EMC = EMC-specific settings HP = HP-specific settings IBM = IBM -specific settings ® QLGC = QLogic-specific settings SUN = Sun or Oracle-specific settings ® The pairs <param name> <param value> and <param alias> <param value> can be repeated to set multiple parameters with a single command.
  • Page 114 6–Fibre Channel Noninteractive Commands -n (Configure HBA Parameters) Table 6-9 lists the adapter parameter names and aliases, alphabetized by name. Table 6-9. Adapter Parameters Description Name Alias Value Connection options 0 = Loop only ConnectionOption 1 = Point-to-point only 2 = Loop preferred, otherwise point-to-point 3 = Point-to-point preferred, otherwise loop...
  • Page 115 Hard Loop ID options are not available for QLogic 8200 Series Adapters. Enable Receive Out of Order Frames option is available only for QLogic 2400 Series Adapters. Execution throttle does not apply to 2600 and 8300 Series Adapters. Execution throttle is read-only for 10GbE adapters.
  • Page 116: P (Target Persistent Bindings)

    6–Fibre Channel Noninteractive Commands -p (Target Persistent Bindings) Where the file name is systemLUNinfo, all messages are located in the directory indicated for the system platform: Windows: syslog.log in the current directory Linux: /var/log/messages Mac OS: /var/log/system.log Solaris: /var/adm/messages (Target Persistent Bindings) Use the -p command to: ...
  • Page 117 6–Fibre Channel Noninteractive Commands -p (Target Persistent Bindings) The following example is a typical QConvergeConsole CLI output showing all targets currently bound to an adapter: -------------------------------------------------------------------------- HBA 0: QLA2462 Port 1 WWPN xx-xx-xx-xx-xx-xx-xx-xx Port ID 11-06-EF -------------------------------------------------------------------------- Bind Type Device Node Name Device Port Name Port ID ----...
  • Page 118: Pa (Adapter Port Alias [Fcoe Configuration])

    6–Fibre Channel Noninteractive Commands -pa (Adapter Port Alias [FCoE Configuration]) Where: hba instance = Adapter number (use the -g command to find) hba wwpn = World wide port name of the adapter target wwnn = World wide node name of the target To unbind all targets on a specific adapter port or on all adapter ports, issue the following command: # qaucli -pr fc -p (<hba instance>...
  • Page 119: Pc (Adapter Personality Change)

    -pc (Adapter Personality Change) (Adapter Personality Change) NOTE  The personality feature is supported only on QLogic QLE267x and QLE836x adapters. This feature lets you set the adapter’s personality to Fibre Channel only or Converged Network Adapter. Use the -pc command to change an adapter’s personality between Fibre Channel only (FC only) and Converged Network Adapter (CNA).
  • Page 120: Q (Target Link Speed [Iidma])

    6–Fibre Channel Noninteractive Commands -q (Target Link Speed [iiDMA]) If both target id and lun id are omitted, the -pl command lists all udev names that are currently assigned to all devices attached to a physical port on the adapter. To remove a udev persistent device name from a LUN, issue the following command: # qaucli -pr fc -pl (<hba instance>...
  • Page 121: R (Parameters Update; Save Hba Parameters)

    6–Fibre Channel Noninteractive Commands -r (Parameters Update; Save HBA Parameters) Where: hba instance = Adapter number (use the -g command to find) hba wwpn = World wide port name of the adapter target wwpn = World wide port name of the target To set the link speed of all targets attached to one adapter or all adapters to the designated speed, issue the following command: # qaucli -pr fc -q (<hba instance>...
  • Page 122 6–Fibre Channel Noninteractive Commands Where: hba instance = Adapter number (use the -g command to find) hba wwpn = World wide port name of the adapter all = All adapter ports in the system are updated with the new adapter parameters File Name = File name or a path to a file that contains the updated adapter parameters To save the adapter parameters to a file, issue the following command:...
  • Page 123: T (Fc Target/Lun Information)

    6–Fibre Channel Noninteractive Commands -t (FC Target/LUN Information) Where: hba instance = Adapter number (use the -g command to find) hba wwpn = World wide port name of the adapter file name = Name of the firmware preload table DAT file. This feature is supported with 8Gb mezzanine and blade adapters.
  • Page 124: Trace

    = World wide port name of the adapter file name = Name of the firmware preload table DAT file. NOTE After the trace file has been saved, send it to QLogic Technical Support (see “Technical Support” on page xxiii for contact information).
  • Page 125: Vp (Virtual Ports [Npiv])

    QConvergeConsole CLI v1.x.x Build x Copyright 2003-2009 QLogic Corp. All rights reserved. Command Line QLogic FC Host Bus Adapters. Build Type: Release Build Date: xx/xx/xxxx xx:xx:xx AM (Virtual Ports [NPIV]) To list all virtual ports on a physical adapter port, issue the -vp command as follows: # qaucli -pr fc -vp (<hba instance>...
  • Page 126 6–Fibre Channel Noninteractive Commands To list a specific virtual port on a physical adapter port, issue the following command: # qaucli -pr fc -vp (<hba instance> : <hba wwpn>) list <vport wwpn> To create a virtual port with an automatic WWPN, issue the following command: # qaucli -pr fc -vp (<hba instance>...
  • Page 127: Z (All Information)

    6–Fibre Channel Noninteractive Commands -z (All Information) When you use this option, the system shows all result and status messages in XML format 2, the standard XML format. This option is usually combined with the -o option (see “-o” on page 6-29) to create a text file with XML output so that it can be parsed by an XML-compliant utility.
  • Page 128 6–Fibre Channel Noninteractive Commands -z (All Information) 6-42 SN0054667-00 G...
  • Page 129: Iscsi Noninteractive Commands

    Noninteractive Commands This chapter describes the noninteractive iSCSI command format and parameters of QConvergeConsole CLI for QLogic 8200 Series Converged Network Adapters. NOTE To view help, issue the -h command. Command Format The noninteractive iSCSI command format is as follows: qaucli -pr iscsi [optional parameters] <Command Option>...
  • Page 130: Command Summary

    7–iSCSI Noninteractive Commands Command Summary Table 7-1. Noninteractive Command Variables (Continued) Variable Definition CHAP Name Null-terminated CHAP name, which is sent by the port instance when responding to the CHAP challenge CHAP Secret CHAP secret, which is used by the port instance when gener- ating the CHAP response Boot Target The target ID of the target device from which to boot Boot LUN The LUN of the boot device...
  • Page 131 7–iSCSI Noninteractive Commands Command Summary NOTE A parenthetical phrase after a command indicates the equivalent interactive menu option. For example, -addchap indicates that the (Add a CHAP Entry) -addchap command has an equivalent Add a CHAP Entry menu option described in Chapter 11 Converged Network Adapter Interactive Commands.
  • Page 132 7–iSCSI Noninteractive Commands Command Summary  -h (Help)   -import (Import HBA Configuration)  -ipdhcp (Configure IP Settings)  -l (List LUN Information)  -lcd (Display Configured Link Configuration)  -linkchap (Assign a CHAP Entry to a Target)  -lp (Display Local Prefix List [IPv6]) ...
  • Page 133: Acb

    -bootcode command updates the boot code image, which should be done when QLogic releases a new boot code with bug fixes or enhancements. At the prompt, type the name of the file containing the boot code image to upload to the adapter.
  • Page 134: C (Cna Port Information-Iscsi)

    7–iSCSI Noninteractive Commands -c (CNA Port Information—iSCSI) To update the boot code image, issue the -bootcode command as follows: -bootcode <hba_port_inst> <bootcode image file name> (CNA Port Information—iSCSI) To view the configured settings for the port, issue the -c command as follows: -c [hba_port_inst] When you specify a port instance, information for only that adapter is shown.
  • Page 135: D (Drivers Update)

    7–iSCSI Noninteractive Commands -d (Drivers Update) (Drivers Update) To install an adapter driver for all iSCSI adapters on the system from a .zip or .inf file, issue the -d command as follows: -d <file_name> A system reboot may be required; see the log file for details. (Display Destination Cache [IPv6]) The IPv6 destination cache contains the IP address, next-hop IP address, and path MTU information for both local and remote destinations.
  • Page 136: Dr (Display Default Router List [Ipv6])

    7–iSCSI Noninteractive Commands To view the firmware properties, issue the -df command as follows: -df <hba_port_inst> QConvergeConsole CLI displays information about the adapter: model, serial number, port number, iSCSI name, alias, IP address, instance number, and the following firmware information: ...
  • Page 137: Dspchap (Display Chap Table)

    7–iSCSI Noninteractive Commands -dspchap (Display CHAP Table) -dspchap (Display CHAP Table) To view the CHAP table, issue the -dspchap command as follows: -dspchap <hba_port_inst> -dtdsp (Display Discovered Targets) To view the discovered targets that are not persistent, issue the -dtdsp command as follows: -dtdsp <hba_port_inst>...
  • Page 138: Dtlia (Login And Persist A Discovered Target)

    7–iSCSI Noninteractive Commands -dtlia (Login and Persist a Discovered Target) -dtlia (Login and Persist a Discovered Target) To log in all discovered targets, issue the -dtlia command as follows: -dtlia <hba_port_inst> -dtrem (Remove Discovered Target) To remove a nonpersistent discovered target, issue the -dtrem command as follows: -dtrem <hba_port_inst>...
  • Page 139 7–iSCSI Noninteractive Commands You can repeat the <Parameter>|<Parameter Alias> <Value> parameter pair to change multiple values as shown in Table 7-2. Press ENTER after each entry. Table 7-2. CHAP Parameters Parameter Parameter Alias Value character string CHAPName CNAME character string CHAPSecret CSECRET on or off...
  • Page 140: Gcr

     Connection medium  IP address (IP address of the adapter port instance)  iSCSI name (adapter port iSCSI name; the QLogic default name or one you assign) Alias (adapter port instance iSCSI alias name that you assign)  7-12...
  • Page 141: Import (Import Hba Configuration)

    0. HBA 0 Port: 0 HBA Port Instance: 0 HBA Model: QLA4050C HBA Serial Number: FS20525B03135 FW Version: 2.2.4.45 Type: Copper IP Address: 192.168.3.7 Alias: iSCSI name: iqn.2000-04.com.qlogic.fs10506a02810.1 1. HBA 1 Port: 0 HBA Port Instance: 1 HBA Model: QLA4062C HBA Serial Number: AS40637A04673 FW Version: 3.0.1.18 Type: Copper IP Address: 192.168.3.22...
  • Page 142: Ipdhcp (Configure Ip Settings)

    7–iSCSI Noninteractive Commands -ipdhcp (Configure IP Settings) F = Configure the firmware. N = Configure the network parameters. I = Configure the iSCSI name. T = Configure the targets. C = Configure the CHAP table. B = Configure the boot parameters (only valid when the T [targets] parameter is also specified).
  • Page 143: Lcd (Display Configured Link Configuration)

    7–iSCSI Noninteractive Commands -lcd (Display Configured Link Configuration) You can view this information for a specific LUN or for all LUNs attached to the selected target. To list the LUN information, issue the -l command as follows: -l <hba_port_inst> <target_ID> [LUN ID] If you do not include the LUN ID parameter, all the LUNs on the specified target are shown.
  • Page 144: N (Configure Iscsi Settings)

    7–iSCSI Noninteractive Commands -n (Configure iSCSI Settings) (Configure iSCSI Settings) To set the adapter iSCSI parameters for single-port adapters, issue the -n command as follows: -n <hba_port_inst> <config_name|config_alias> <value> [<config_name|config_alias> <value> …] After you issue this command, the adapter is reset. You can repeat the (<config_name>|<config_alias>...
  • Page 145: Nc (Display Neighbor Cache [Ipv6])

    7–iSCSI Noninteractive Commands -nc (Display Neighbor Cache [IPv6]) Table 7-3. Adapter Parameters (Continued) Configuration Name Configuration Alias Value <config_name> <config_alias> <value> iSCSI_Snack ISNACK on or off iSCSI_Strict_Login on or off TCP Options TCP_Auto_Discovery SLPADIS on or off TCP_DHCP TCPDHCP on or off TCP_Nagle TCPN on or off...
  • Page 146: Netconf6 (Configure Ipv6 Settings)

    7–iSCSI Noninteractive Commands -netconf6 (Configure IPv6 Settings) Setting the IP address, subnet mask, or gateway turns off DHCP address resolution for the IP configuration, if it is on. -netconf6 (Configure IPv6 Settings) To manually configure the IPv6 network settings, issue the -netconf6 command as follows: -netconf6 <hba_port_inst>...
  • Page 147: Nh (Configure Iscsi Settings)

    7–iSCSI Noninteractive Commands -nh (Configure iSCSI Settings) To set everything automatically, issue the following command: -netconf6 0 -IPLLA -IPR01A -IPRRA To disable the IPv4 network, issue the following command: -netconf6 0 -DISN4 To disable the IPv4 and IPv6 networks, issue the following command: -netconf6 0 -DISN4 DISN6 (Configure iSCSI Settings) To set the adapter-level parameters for multiport adapters, issue the -nh...
  • Page 148: Pdt (Disable A Target)

    7–iSCSI Noninteractive Commands -pdt (Disable a Target) For information on secondary boot code, see “-sbootcode (Set Secondary Boot Target Information)” on page 7-24. -pdt (Disable a Target) To disable a target, issue the -pdt command as follows: -pdt <hba_port_inst> <targetId> -pet (Enable a Target) To enable a target, issue the -pet command as follows:...
  • Page 149 -px <hba_port_inst> Use the -r command option to update the ROM image. CAUTION  Before attempting to update the ROM image, contact QLogic Customer Support.  Before updating the ROM image, ensure that no I/O processes are running.  An administrator must take necessary actions to ensure changes are fully recognized by the operating system (reboot, flush cache, sync disk, and so forth).
  • Page 150: Rdf

    7–iSCSI Noninteractive Commands -rdf -rdf To restore the specified adapter port’s firmware values to the factory default values, issue the -rdf command: -rdf <hba_port_inst> Issuing this command resets the adapter. -rdh (Port Restore Factory Defaults) Type the following command to restore the specified adapter port’s settings to their factory defaults: -rdh <hba_port_inst>...
  • Page 151: Rwt (Read Write Buffer Test-Iscsi)

    7–iSCSI Noninteractive Commands -rwt (Read Write Buffer Test—iSCSI) -rwt (Read Write Buffer Test—iSCSI) CAUTION Before running a read/write buffer test, make sure that the adapter does not have any outstanding I/O operations. The read/write buffer test writes an 8- or 16-byte pattern to the disk’s buffer and reads the written buffer back.
  • Page 152: Save (Save Host Configuration)

    7–iSCSI Noninteractive Commands -save (Save Host Configuration) -save (Save Host Configuration) To save the configuration (in XML) of all adapters detected, issue the -save command as follows: -save <file_name> -sbootcode (Set Secondary Boot Target Information) To set the secondary boot target and LUN, issue the -sbootcode command as follows: -sbootcode <hba_port_inst>...
  • Page 153: Statport (Display Iscsi Port Statistics)

    7–iSCSI Noninteractive Commands -statport (Display iSCSI Port Statistics) NOTE To use the -stdsp, -strd, and -strem commands, you must first issue the -stadd command at least once to add a send target for discovery only (no target login). After using the -stadd command to add at least one send target for discovery only, you can use the -stdsp command to display all send targets for discovery, along with the appropriate index to be used for the -strd and -strem commands.
  • Page 154: Strd (Mark Send Target For Re-Discovery)

    7–iSCSI Noninteractive Commands -strd (Mark Send Target for re-discovery) -strd (Mark Send Target for re-discovery) To execute a rediscovery of targets for the specified send target, issue the -strd command as follows: -strd <hba_port_inst> <target_instance> To obtain the target instance, use the -dtdsp command. To use the -strd command, you must first issue the -stadd command at least once to add a send target for discovery only.
  • Page 155: Ver

    To view the QConvergeConsole CLI utility version, issue the -ver command as follows: -ver -vpd (CNA VPD Information—iSCSI) To view VPD information, if any, issue the -vpd command as follows: -vpd <hba_port_inst> Available VPD information varies by adapter manufacturer. QLogic adapters ship with VPD information shown as N/A. SN0054667-00 G 7-27...
  • Page 156 7–iSCSI Noninteractive Commands -vpd (CNA VPD Information—iSCSI) 7-28 SN0054667-00 G...
  • Page 157: Nic Partitioning (Npar) Noninteractive Commands

    NIC Partitioning (NPAR) Noninteractive Commands This chapter describes the noninteractive NIC partitioning (NPAR) command format and parameters of QConvergeConsole CLI. NPAR is supported by QLogic 3200 Series Intelligent Ethernet Adapters and 8200 and 8300 Series Converged Network Adapters. NOTE SR-IOV and NPAR cannot be enabled at the same time. If SR-IOV is enabled on the host, all NPAR-related commands are disabled.
  • Page 158: Command Summary

    8–NIC Partitioning (NPAR) Noninteractive Commands Command Summary    -peswitchcfg  -pinfo (NPAR Port Information)  -restoreeswitchcfg (Restore eSwitch Configuration)  -setmaxbw (Modify Maximum Bandwidth)  -setminbw (Modify Minimum Bandwidth) Command Summary This section lists the NPAR commands in alphabetic order, and provides a description of each.
  • Page 159: Eswitchinfo

    8–NIC Partitioning (NPAR) Noninteractive Commands  Specify fcoe to change the personality type to Fibre Channel over Ethernet (FCoE).  Specify disable to disable the function. To get NPAR command line return codes, issue the -ei command as follows: > qaucli -npar -ei -eswitchinfo To get NPAR eSwitch information, issue the -eswitchinfo command as follows:...
  • Page 160: Finfo

    8–NIC Partitioning (NPAR) Noninteractive Commands -finfo Table 8-1. eSwitch Physical Function Options Option Value 1 (enable) or 0 (disable) discard tagged configuration discard_tagged 1 (enable) or 0 (disable) MAC address change configuration mac_addr_change 1 (enable) or 0 (disable) MAC anti-spoof check mac_anti_spoof_chk 1 (enable) or 0 (disable) promiscuous mode configuration promisc_mode...
  • Page 161: Peswitchcfg

    8–NIC Partitioning (NPAR) Noninteractive Commands To view a list of NPAR physical functions, issue the -if command as follows: > qaucli -npar -if To view a list of the NPAR physical ports, issue the -ip command as follows: > qaucli -npar -ip -peswitchcfg To change eSwitch physical port configuration, issue the -peswitchcfg command as follows:...
  • Page 162: Setmaxbw (Modify Maximum Bandwidth)

    8–NIC Partitioning (NPAR) Noninteractive Commands -setmaxbw (Modify Maximum Bandwidth) The eSwitch configuration information is restored from the eswitch.cfg file in the installation directory. -setmaxbw (Modify Maximum Bandwidth) To set the NPAR maximum bandwidth value, issue the -setmaxbw command as follows: >...
  • Page 163: Nic Interactive Commands

    NIC Interactive Commands This chapter describes the interactive mode command line options for QLogic Intelligent Ethernet Adapters. The interactive mode uses a series of menus from which you select the option you want and type the number for that option.
  • Page 164: Adapter Information

    9–NIC Interactive Commands Adapter Information NOTE For interactive commands that have an equivalent noninteractive command line option, the noninteractive command is shown in parentheses following the interactive command. For example, the CNA Adapter Information command described in this chapter has an equivalent -icna command line option described in Chapter 5 NIC Noninteractive Commands.
  • Page 165: Cna Port Information (-Pinfo)

    9–NIC Interactive Commands CNA Port Information (-pinfo) (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 ------------------------------------------------------------------ Hostname : amd-28 Adapter Model : QLE3242 Chip Model : 8020 Chip Version : B0 Adapter Alias : None Serial Number...
  • Page 166: Cna Vpd Information (-Vpd)

    : 1500 Interface Scope ID Interface Speed : 10 Gbps Interface Description : QLE3242 QLogic Pci Express to 10GbE Dual Channel ------------------------------------------------------------------ CNA VPD Information (-vpd) 1. Adapter Information1. Converged Network Adapter3. CNA VPD Information From the Converged Network Adapter Information menu, select the CNA VPD Information option.
  • Page 167: Adapter Configuration

    9–NIC Interactive Commands Adapter Configuration Serial Number : AFE1030C04339 Manufacturing Id : NE3210404-02 Flash Image Version : 010437 ------------------------------------------------------------------ Adapter Configuration 2. Adapter Configuration1. CNA Configuration From the main menu, select the Adapter Configuration option, and then select the adapter type (CNA Configuration). The Converged Network Adapter (CNA) NIC Configuration menu presents options to configure the adapter alias and the NIC port settings.
  • Page 168: Nic Port Setting Configuration (-C)

    Port Settings Menu ======================================================= : 0 Port 2 : AFE1030C04339 CNA Model : QLE3242 CNA Desc. : QLE3242 QLogic Pci Express to 10GbE Dual Channel Ethernet Adapters MPI Fw Version: 4.07.31 Physical MAC : 00-0E-1E-04-D3-34 LAA MAC : 00-0E-1E-04-D3-34 IPv4 Address : 0.0.0.0...
  • Page 169: Display Configured Port Settings (-Iset)

    9–NIC Interactive Commands NIC Port Setting Configuration (-c) Display Configured Port Settings (-iset) 2. Adapter Configuration1. CNA Configuration2. NIC Port Setting Configuration<port selection> 1. Display Configured Port Settings From the Port Settings Menu, select the Display Configured Port Settings option to view the configure port parameters. For example: IPv4_Checksum_Offload_Enable : RxTx Jumbo_Frames_MTU_9000_Enable...
  • Page 170: Change Mac Alias Name (-N)

    9–NIC Interactive Commands Adapter Updates Change MAC Alias Name (-n) 2. Adapter Configuration1. CNA Configuration2. NIC Port Setting Configuration<port selection> 4. Change MAC Alias Name From the Port Settings Menu, select the Change MAC Alias Name option to change the aliases for the physical MAC address alias and the active/LAA MAC address.
  • Page 171: Flash Update (-Updimages)

    9–NIC Interactive Commands Flash Update (-updimages) Flash Update (-updimages) 3. Adapter Updates1. Converged Network Adapter1. Flash Update From the CNA Adapter Update menu, select the Flash Update option to update Flash memory. From the adapter menu, select an adapter for which to update Flash memory, and then type the name of the file that contains the Flash image.
  • Page 172: Register Test (-Testregister)

    9–NIC Interactive Commands Register Test (-testregister) Register Test (-testregister) 4. Adapter Diagnostics1. Converged Network Adapter1. Register Test From the Converged Network Adapter (CNA) Diagnostics menu, select the Register Test option. From the port menu, select a port for which to run the register test.
  • Page 173: Interrupt Test (-Testinterrupt)

    9–NIC Interactive Commands Interrupt Test (-testinterrupt) Test Status: Passed (Passed=1, Failed=0, ErrorCode=0) Hardware Test Results: Status=Passed Passed=1, Failed=0, ErrorCode=0 Interrupt Test (-testinterrupt) 4. Adapter Diagnostics1. Converged Network Adapter3. Interrupt Test From the Converged Network Adapter (CNA) Diagnostics menu, select the Interrupt Test option.
  • Page 174: Beacon/Led Test (-Testled)

    9–NIC Interactive Commands Beacon/LED Test (-testled) 1. Port 1 [Protocol(s): NIC] MAC Address: 00:0E:1E:04:D3:30 2. Port 2 [Protocol(s): NIC] MAC Address: 00:0E:1E:04:D3:34 (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Link Test Starts ...
  • Page 175: Adapter Statistics

    9–NIC Interactive Commands Adapter Statistics Adapter Statistics 5. Adapter Statistics1. Converged Network Adapter From the main menu, select the Adapter Statistics option and then select Converged Network Adapter. The Converged Network Adapter (CNA) Statistics menu presents options to view NIC port statistics, reset logging parameters, and undo resetting.
  • Page 176: Reset Nic Statistics (-Sreset)

    9–NIC Interactive Commands Reset NIC Statistics (-sreset) txUnicastPkts txControlPkts txPausePkts txPkts64Octets Reset NIC Statistics (-sreset) 5. Adapter Statistics1. Converged Network Adapter2. Reset NIC Statistics From the Converged Network Adapter (CNA) Statistics menu, select the Reset NIC Statistics option. From the port menu, select a port for which to reset the NIC port statistics counters to zero.
  • Page 177: Refresh

    6. Refresh From the main menu, select the Refresh option to refresh (reload) the adapters and adapter port indexes. For example: Scanning for QLogic adapters, please wait... Using config file: C:\Program Files\...\iscli.cfg Using config file: C:\Program Files\...\netscli.cfg Loading: 1. CNA ... adapters, please wait...
  • Page 178 9–NIC Interactive Commands Exit 9-16 SN0054667-00 G...
  • Page 179: Fibre Channel Interactive Commands

    Fibre Channel Interactive Commands This chapter describes the interactive mode command line options for Fibre Channel Adapters. The interactive mode uses a series of menus from which you select the option you want by typing the number for that option. For information about noninteractive mode operation—in which you simply type a short code to perform operations on the adapter—refer to Chapter 6 Fibre...
  • Page 180: Adapter Information

    10–Fibre Channel Interactive Commands Adapter Information NOTE For interactive commands that have an equivalent noninteractive command line option, the noninteractive command is shown in parentheses following the interactive command. For example, the FC Adapter Information command described in this chapter has an equivalent -i command line option described in Chapter 6 Fibre Channel Noninteractive Commands.
  • Page 181: Fc Port Information

    10–Fibre Channel Interactive Commands FC Port Information (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 FC Adapter Information ------------------------------------------------------------------ Host Name : amd-28 HBA Model : QLE2462 HBA Description : QLE2462 PCI Express to 4Gb FC Dual Channel HBA Alias Serial Number...
  • Page 182: Fc Vpd Information (-I)

    10–Fibre Channel Interactive Commands FC VPD Information (-i) BIOS Version : 1.24 Driver Firmware Version : 4.04.09 (486) Flash BIOS Version : 1.24 Flash FCode Version : 1.24 Flash EFI Version : 1.08 Flash Firmware Version : 4.00.26 Actual Connection Mode : Unknown Actual Data Rate : Unknown...
  • Page 183: Fc Target/Lun Information (-T)

    10–Fibre Channel Interactive Commands FC Target/LUN Information (-t) Link : Online ------------------------------------------------------------------ ------------------------------------------------------------------ HBA Instance 0: QLE2462 Port 1 WWPN 21-00-00-1B-32-17-F9-C4 PortID 00-00-00 ------------------------------------------------------------------ Product Identifier : PCI-Express Dual Channel 4Gb Fibre Channel HBA Part Number : QLE2462 Serial Number : GFC0718P57753 Misc.
  • Page 184: Adapter Configuration

    10–Fibre Channel Interactive Commands Adapter Configuration Device (Offline) Vendor : N/A Product ID : N/A Product Rev : N/A Serial Number Node Name : 50-0A-09-80-87-E9-60-73 Port Name : 50-0A-09-83-87-E9-60-73 Port ID : 2B-00-20 All Target(s) Adapter Configuration 2. Adapter Configuration2. Fibre Channel Adapter From the main menu, select the Adapter Configuration option, and then select the adapter type (Fibre Channel Adapter).
  • Page 185: Adapter Alias (-Ha)

    10–Fibre Channel Interactive Commands Adapter Alias (-ha) NOTE The options supported and available on the Fibre Channel Adapter Configuration menu depend on the drivers and operating system detected. You may not see all of the options listed above and described in this section of the guide.
  • Page 186: Adapter Port Alias (-Pa)

    10–Fibre Channel Interactive Commands Adapter Port Alias (-pa) Adapter Port Alias (-pa) 2. Adapter Configuration2. Fibre Channel Adapter2. Adapter Alias From the Fibre Channel Adapter Configuration menu, select the Adapter Port Alias option. From the port menu, select a port to view or change its port alias. The port’s information is displayed followed by a prompt identifying the current port alias in brackets.
  • Page 187: Display Hba Parameters (-C)

    10–Fibre Channel Interactive Commands HBA Parameters 1: Port 1: WWPN: 21-00-00-1B-32-17-F9-C4 online 2: Port 2: WWPN: 21-01-00-1B-32-37-F9-C4 Loop Down (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 HBA Parameters Menu ======================================================= : 0 Port: 1 : GFC0718P57753...
  • Page 188: Configure Hba Parameters (-N)

    10–Fibre Channel Interactive Commands HBA Parameters Login Retry Count Port Down Retry Count : 30 Enable LIP Full Login : Enabled Link Down Timeout (seconds) : 30 Enable Target Reset : Enabled LUNs Per Target : 128 Out Of Order Frame Assembly : Disabled NOTE Execution Throttle does not apply to 2600 and 8300 Series Adapters and is...
  • Page 189: Restore Defaults

    10–Fibre Channel Interactive Commands HBA Parameters Enable HBA Hard Loop ID Enable Fibre Channel Tape Support Operation Mode Interrupt Delay Timer (100ms) Execution Throttle Login Retry Count Port Down Retry Count Enable LIP Full Login Link Down Timeout (seconds) Enable Target Reset LUNs per Target Enable Receive Out Of Order Frame Commit Changes...
  • Page 190: Target Persistent Binding (-P)

    Please Enter Selection: 1 Target Persistent Binding Menu ======================================================= : 0 Port: 1 : AFE1134C09753 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA (FCoE) FW Version : 6.00.10 WWPN : 21-00-00-0E-1E-08-09-10 WWNN : 20-00-00-0E-1E-08-09-10 Link...
  • Page 191 10–Fibre Channel Interactive Commands Persistent Names (-pl) Linux systems: From the port menu, select a port to open the Target List Menu, and then select the target to display the LUN List Menu, with options to display LUN information or manage persistent names.
  • Page 192 10–Fibre Channel Interactive Commands Persistent Names (-pl) Disk (Online) Vendor : SANBlaze Product ID : VLUN FC RAMDisk Product Rev : 3.1. Serial Number : 2fff00062b0f569901000000 Node Name : 2F-DF-00-06-2B-0F-56-99 Port Name : 2F-DF-00-06-2B-0F-56-99 Port ID : 01-04-01 Disk (Online) Vendor : SANBlaze Product ID...
  • Page 193 10–Fibre Channel Interactive Commands Persistent Names (-pl) Node Name : 21-00-00-24-FF-6A-51-88 Port Name : 21-00-00-24-FF-6A-51-88 Port ID : 01-0B-00 All Target(s) (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 QConvergeConsole Version 1.0.3 (Build 40) LUN List Menu HBA Instance 1 (QLE2672 Port 2) : Online...
  • Page 194 10–Fibre Channel Interactive Commands Persistent Names (-pl) Product ID : VLUN FC RAMDisk Port Name : 2F-DF-00-06-2B-0E-B2-44 Port ID : 01-06-01 All LUN(s) (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 QConvergeConsole Version 1.0.3 (Build 40) LUN List Menu...
  • Page 195 10–Fibre Channel Interactive Commands Persistent Names (-pl) QConvergeConsole Version 1.0.3 (Build 40) LUN List Menu ======================================================= : 1 Port: 2 : AFE1224F05259 HBA Model : QLE2672 HBA Desc. : QLE8362 Sun Storage 16Gb FC PCIe Universal HBA FW Version : 6.06.00 WWPN : 21-00-00-0E-1E-08-F2-01 WWNN...
  • Page 196 10–Fibre Channel Interactive Commands Persistent Names (-pl) Delete (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Product Vendor : SANBlaze Product ID : VLUN FC RAMDisk Product Revision : 3.1 WWULN : 60-00-62-B0-00-0E-B2-44-00-00-00-01-00-00-00-00 OS LUN Name...
  • Page 197 10–Fibre Channel Interactive Commands Persistent Names (-pl) WWULN : 60-00-62-B0-00-0E-B2-44-00-00-00-01-00-00-00-00 OS LUN Name : /dev/sdr;/dev/sg18; ------------------------------------------------------------ Enter new persistent LUN name: @Lun0 Persistent LUN name @Lun0 has been added to target 0 LUN 0. Press <Enter> to continue: QConvergeConsole Version 1.0.3 (Build 40) Persistent Names Menu ======================================================= : 1 Port: 2...
  • Page 198: Display Configuration

    10–Fibre Channel Interactive Commands Persistent Names (-pl) Display Configuration 2. Adapter Configuration2. Fibre Channel Adapter2. Target Persistent Bindings<port selection> 1. Display Configuration From the Target Persistent Bindings Menu, select the Display Configuration option to view the target binding configuration. For example: (p or 0: Previous Menu;...
  • Page 199: Unbind Target(S)

    10–Fibre Channel Interactive Commands Persistent Names (-pl) 1: Disk Vendor : SEAGATE Product ID : ST318453FC Port Name : 22-00-00-04-CF-9C-24-CA Port ID : 02-00-E1 Bind : No Target ID : 2: Disk Vendor : SEAGATE Product ID : ST318453FC Port Name : 22-00-00-0C-50-68-1E-9A Port ID : 11-0A-E2...
  • Page 200: Boot Devices Configuration

    10–Fibre Channel Interactive Commands Boot Devices Configuration WWNN : 20-00-00-1B-32-17-F9-C4 Link : Online ======================================================= 1: Disk Vendor : SEAGATE Product ID : ST318453FC Port Name : 22-00-00-04-CF-9C-24-CA Port ID : 02-00-E1 Bind : Yes Target ID : 2: Disk Vendor : SEAGATE Product ID : ST318453FC...
  • Page 201: Display Boot Device(S) (-E)

    10–Fibre Channel Interactive Commands Boot Devices Configuration ======================================================= : 0 Port: 1 : GFC0718P57753 HBA Model : QLE2462 HBA Desc. : QLE2462 PCI Express to 4Gb FC Dual Channel FW Version : 4.00.26 WWPN : 21-00-00-1B-32-17-F9-C4 WWNN : 20-00-00-1B-32-17-F9-C4 Link : Online ======================================================= Display Boot Device(s)
  • Page 202: Configure Boot Device(S) (-E)

    10–Fibre Channel Interactive Commands Boot Devices Configuration 00-00-00-00-00-00-00-00 Configure Boot Device(s) (-e) 2. Adapter Configuration2. Fibre Channel Adapter3. Boot Devices Configuration<port selection>2. Configure Boot Device(s) From the Boot Device Settings Menu, select the Configure Boot Device(s) option to open the Boot Device Settings submenu with options to configure the primary and alternate boot devices.
  • Page 203: Virtual Ports (Npiv) (-Vp)

    10–Fibre Channel Interactive Commands Virtual Ports (NPIV) (-vp) ======================================================= Device Selectable Boot: Enabled (Primary) Boot Port Name: 50-0A-09-83-87-E9-60-73 LUN: 0 BIOS boot default Selectable Boot: Enabled Alternate 1 (2, 3) Boot Device 2. Adapter Configuration2. Fibre Channel Adapter3. Boot Devices Configuration<port selection>2.
  • Page 204: Target Link Speed (Iidma) (-Q)

    10–Fibre Channel Interactive Commands Target Link Speed (iiDMA) (-q) 1: Port 1: WWPN: 21-00-00-1B-32-0C-95-0C Link Down 2: Port 2: WWPN: 21-01-00-1B-32-2C-95-0C Link Down (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 QConvergeConsole Version 1.0.2 (Build 13) vPorts Menu...
  • Page 205: Basic Configuration

    10–Fibre Channel Interactive Commands Target Link Speed (iiDMA) (-q) WWPN : 21-00-00-1B-32-17-F9-C4 WWNN : 20-00-00-1B-32-17-F9-C4 Link : Online ======================================================= Basic Configuration Advance Configuration Basic Configuration 2. Adapter Configuration2. Fibre Channel Adapter4. Target Link Speed (iiDMA)1. Basic Configuration From the iiDMA Menu, select the Basic Configuration option to specify the link speed.
  • Page 206: Driver Parameters (-Fs)

    10–Fibre Channel Interactive Commands Driver Parameters (-fs) Link : Online ======================================================= Device Vendor : N/A Product ID : N/A Product Rev : N/A Serial Number Port Name : 50-0A-09-83-87-E9-60-73 Port ID : 2B-00-20 Intelligent Interleave Factor: 4 Gbps Apply Changes to selected Target(s) (p or 0: Previous Menu;...
  • Page 207: Selective Luns (-M)

    LUNs. For example: Selective LUNs Menu ======================================================= : 0 Port: 1 : AFE1134C09753 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA (FCoE) FW Version : 6.00.10 WWPN : 21-00-00-0E-1E-08-09-10 WWNN : 20-00-00-0E-1E-08-09-10 Link...
  • Page 208: Display Lun Configuration

    Version 1.0.2 (Build 15) Selective LUN Menu (Display) ======================================================= : 0 Port: 1 : AFE1134C09753 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA (FCoE) FW Version : 6.00.10 WWPN : 21-00-00-0E-1E-08-09-10 WWNN : 20-00-00-0E-1E-08-09-10 Link...
  • Page 209 10–Fibre Channel Interactive Commands Selective LUNs (-m) HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA (FCoE) FW Version : 6.00.10 WWPN : 21-00-00-0E-1E-08-09-10 WWNN : 20-00-00-0E-1E-08-09-10 Link : Online ======================================================= Disk Vendor : SANBlaze Product ID...
  • Page 210: Manual Configure Luns

    10–Fibre Channel Interactive Commands Selective LUNs (-m) ======================================================= : 0 Port: 1 : AFE1134C09753 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA (FCoE) FW Version : 6.00.10 WWPN : 21-00-00-0E-1E-08-09-10 WWNN : 20-00-00-0E-1E-08-09-10 Link...
  • Page 211: Quality Of Service (Qos)

    10–Fibre Channel Interactive Commands Quality of Service (QoS) Quality of Service (QoS) 2. Adapter Configuration2. Fibre Channel Adapter10. QoS From the Fibre Channel Adapter Configuration menu, select the QoS option. From the port menu, select a port to open the QoS Type Menu with options to set QoS by priority or by bandwidth.
  • Page 212: Export (Save) Configuration

    10–Fibre Channel Interactive Commands Export (Save) Configuration Export (Save) Configuration 2. Adapter Configuration2. Fibre Channel Adapter11. Export (Save) Configuration From the Fibre Channel Adapter Configuration menu, select the Export (Save) Configuration option. From the port menu, select a port to open the Export (Save) Configuration menu with options to save Flash memory and adapter parameters.
  • Page 213: Generate Reports (-G)

    2. Adapter Configuration2. Fibre Channel Adapter13. Personality NOTE d ed  The personality feature is supported only on QLogic QLE267x and QLE836x Adapters. This feature lets you set the adapter’s personality to Fibre Channel only or Converged Network Adapter. SN0054667-00 G...
  • Page 214 10–Fibre Channel Interactive Commands Personality (-pc) From the Fibre Channel Adapter Configuration menu, select the Personality option to set the adapter personality to Fibre Channel only or Converged Network Adapter. From the adapter menu, select the adapter whose personality is to be changed, and then confirm your selection, as shown in the following examples.
  • Page 215: Adapter Updates

    10–Fibre Channel Interactive Commands Adapter Updates Adapter Updates 3. Adapter Updates2. Fibre Channel Adapter From the main menu, select the Adapter Updates option and then select 2 (Fibre Channel Adapter). The Fibre Channel Adapter Update menu provides options to update Flash memory, drivers, adapter parameters, the parameter template, and the firmware preload and Fibre Channel SerDes tables, and to perform a Fibre Channel firmware dump.
  • Page 216: Driver Update (-D)

    10–Fibre Channel Interactive Commands Driver Update (-d) Driver Update (-d) 3. Adapter Updates2. Fibre Channel Adapter2. Driver Update NOTE d ed Interactive driver update applies to Windows systems only. From the Fibre Channel Update menu, select the Driver Update option. From the adapter menu, select the adapter, and then type the driver update file name.
  • Page 217: Parameters Update (-R)

    10–Fibre Channel Interactive Commands Parameters Update (-r) Parameters Update (-r) 3. Adapter Updates2. Fibre Channel Adapter3. Parameters Update From the Fibre Channel Update menu, select the Parameters Update option. From the port menu, select a port for which to specify the parameter update, and then type the file name.
  • Page 218: Firmware Preload Table Update (-U)

    10–Fibre Channel Interactive Commands Firmware Preload Table Update (-u) QLGC (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 3 Updating HBA Parameters on HBA instance 0 - QLE2462. Please wait... HBA Parameters update complete. Changes have been saved to HBA instance 0 and are effective immediately.
  • Page 219: Fibre Channel Dump (-Fwdump)

    10–Fibre Channel Interactive Commands Fibre Channel Dump (-fwdump) From the Fibre Channel Update menu, select the FW Serdes Table Update option to update the adapter firmware SerDes table. From the HBA selection menu, select the adapter to be updated and then enter a firmware SerDes table file name (.dat).
  • Page 220: Loopback Test (-Kl)

    10–Fibre Channel Interactive Commands Loopback Test (-kl) (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 FC Diagnostics Loopback Test Read Write Buffer Test Transceiver Diagnostics Monitoring Interface (DMI) Loopback Test (-kl) 4.
  • Page 221: Display Test Parameters

    10–Fibre Channel Interactive Commands Loopback Test (-kl) Display Test Parameters 4. Adapter Diagnostics2. Fibre Channel Adapter1. Loopback Test<port selection>1. Display Test Parameters From the Loopback Test menu, select the Display Test Parameters option to view the external loopback test parameters. For example: ------------------------------------------------------------------------------ HBA Instance 0: QLE2462 Port 1 WWPN 21-00-00-1B-32-17-F9-C4 PortID 00-00-00 ------------------------------------------------------------------------------...
  • Page 222: Start Diagnostics Test

    10–Fibre Channel Interactive Commands Loopback Test (-kl) WWNN : 20-00-00-1B-32-17-F9-C4 Link : Online ======================================================= Data Patterns Data Size Number Of Test(s) Test Increment(s) Abort On Error Start Diagnostics Test 4. Adapter Diagnostics2. Fibre Channel Adapter1. Loopback Test<port selection>4. Start Diagnostics Test From the Loopback Test menu, select the Start Diagnostics Test option to run the external loopback test.
  • Page 223: Read Write Buffer Test (-Kr)

    10–Fibre Channel Interactive Commands Read Write Buffer Test (-kr) Read Write Buffer Test (-kr) 4. Adapter Diagnostics2. Fibre Channel Adapter2. Read Write Buffer Test From the FC Diagnostics menu, select the Read Write Buffer Test option. From the port menu, select a port to open the Read Write Buffer Test menu with options to view test parameters, reset test parameters, configure test parameters, and run the test.
  • Page 224: Reset Test Parameters

    10–Fibre Channel Interactive Commands Read Write Buffer Test (-kr) Reset Test Parameters 4. Adapter Diagnostics2. Fibre Channel Adapter2. Read Write Buffer Test<port selection>2. Reset Test Parameters From the Read Write Buffer Test menu, select the Reset Test Parameters option to reset the read write buffer test parameters to their default values. Configure Test Parameters (-kr) 4.
  • Page 225: Transceiver Diagnostics Monitoring Interface (Dmi)

    10–Fibre Channel Interactive Commands Transceiver Diagnostics Monitoring Interface (DMI) Transceiver Diagnostics Monitoring Interface (DMI) 4. Adapter Diagnostics2. Fibre Channel Adapter3. Transceiver Diagnostics Monitoring Interface (DMI) From the FC Diagnostics menu, select the Transceiver Diagnostics Monitoring Interface (DMI) option. From the port menu, select a port to open the Transceiver Diagnostics Monitoring Interface (DMI) menu with options to view general and detailed transceiver information.
  • Page 226: Details (-Dm)

    10–Fibre Channel Interactive Commands Transceiver Diagnostics Monitoring Interface (DMI) Value 41.78 3.32 7.43 0.3624 0.0001 Status Normal Normal Normal Normal Fault High Alarm 95.00 3.90 17.00 0.6310 1.2590 High Warning 90.00 3.70 14.00 0.6310 0.7940 Low Warning -20.00 2.90 2.00 0.0790 0.0158 Low Alarm...
  • Page 227: Adapter Statistics

    10–Fibre Channel Interactive Commands Adapter Statistics Adapter Statistics 5. Adapter Statistics2. Fibre Channel Adapter From the main menu, select the Adapter Statistics option, and then select the adapter type (Fibre Channel Adapter). The FC Statistics menu presents options to view port statistics and link status. For example: Adapter Type Selection Converged Network Adapter Fibre Channel Adapter...
  • Page 228: Display Parameters (-Gs)

    10–Fibre Channel Interactive Commands Display FC Port Statistics Link : Online ======================================================= Display Parameters Reset Parameters Configure Parameters Display HBA Statistics Display Parameters (-gs) 5. Adapter Statistics2. Fibre Channel Adapter1. Display FC Port Statistics<port selection>1. Display Parameters From the HBA Statistics Menu, select the Display Parameters option to view adapter status logging parameters.
  • Page 229: Display Hba Statistics (-Gs)

    10–Fibre Channel Interactive Commands Display FC Port Link Status Auto Poll Set Rate Set Log File Display HBA Statistics (-gs) 5. Adapter Statistics2. Fibre Channel Adapter1. Display FC Port Statistics<port selection>4. Display HBA Statistics From the HBA Statistics Menu, select the Display HBA Statistics option to view Fibre Channel port statistics.
  • Page 230: Display Parameters

    10–Fibre Channel Interactive Commands Display FC Port Link Status Please Enter Selection: 1 Link Statistics Menu ======================================================= : 0 Port: 1 : GFC0718P57753 HBA Model : QLE2462 HBA Desc. : QLE2462 PCI Express to 4Gb FC Dual Channel FW Version WWPN : 21-00-00-1B-32-17-F9-C4 WWNN...
  • Page 231: Configure Parameters (-Ls)

    10–Fibre Channel Interactive Commands Display FC Port Link Status Configure Parameters (-ls) 5. Adapter Statistics2. Fibre Channel Adapter2. Display FC Port Link Status<port selection>3. Configure Parameters From the Link Statistics Menu, select the Configure Parameters option to open the Link Statistics submenu with options to specify the polling method, the polling rate, and the name of the log file.
  • Page 232: Refresh

    6. Refresh From the main menu, select the Refresh option to refresh (reload) the adapters and adapter port indexes. For example: Scanning for QLogic adapters, please wait... Using config file: C:\Program Files\...\iscli.cfg Using config file: C:\Program Files\...\netscli.cfg Loading: 1. CNA ... adapters, please wait...
  • Page 233: Help (-H)

    10–Fibre Channel Interactive Commands Help (-h) Help (-h) 7. Help From the main menu, select the Help option to view the syntax and description for each noninteractive command line option. For more detailed information about each command, see the noninteractive chapter for the specific adapter type. Exit 8.
  • Page 234 10–Fibre Channel Interactive Commands Exit 10-56 SN0054667-00 G...
  • Page 235: Converged Network Adapter Interactive Commands

    Converged Network Adapter Interactive Commands This chapter describes the interactive mode command line options for Converged Network Adapters. The interactive mode uses a series of menus from which you select the option you want by typing the number for that option. For information on noninteractive mode operation—in which you simply type a short code to perform operations on the adapter—refer to the following chapters for the corresponding adapter function:...
  • Page 236: Adapter Information

    11–Converged Network Adapter Interactive Commands Adapter Information NIC Partitioning (NPAR) Configuration (see page 11-136) NIC Partitioning (NPAR) Statistics (see page 11-139) Refresh (see page 11-142) Help (see page 11-143) Exit (see page 11-143) Please Enter Selection: NOTE For interactive commands that have an equivalent noninteractive command line option, the noninteractive command is shown in parentheses following the interactive command.
  • Page 237: Cna Adapter Information

    Serial Number : AFE1028C03899 MAC Address Function 1 : 00:0e:1e:04:95:ec MAC Address Function 0 : 00:0e:1e:04:95:e8 Driver Information : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Driver Name : qlxgnd64.sys Driver Version : 4.2.15.1125 Active Firmware Version : 4.07.31...
  • Page 238: Fcoe

    Channel over Ethernet (FCoE) adapter information. For example: ------------------------------------------------------------------ Host Name : APPS4055 HBA Model : QLE8242 HBA Description : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) HBA Alias Serial Number : AFE1028C03899 Driver Version : STOR Miniport 9.1.9.15 Driver Firmware Version : 4.07.31...
  • Page 239: Cna Port Information

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 CNA Port Information...
  • Page 240: Fcoe

    For example: ------------------------------------------------------------------------------ Host Name : APPS4055 HBA Instance HBA Model : QLE8242 HBA Description : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) HBA ID : 0-QLE8242 HBA Alias HBA Port Port Alias Node Name : 20-00-00-0E-1E-04-95-EB...
  • Page 241: Iscsi (-C; -Pinfo)

    11–Converged Network Adapter Interactive Commands CNA Port Information Flash EFI Version : N/A Flash Firmware Version : 4.07.31 Actual Connection Mode : Point to Point Actual Data Rate : 10 Gbps PortType (Topology) : NPort Target Count PCI Bus Number PCI Device Number PCI Function Number PCI Device ID...
  • Page 242: Cna Vpd Information

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 CNA VPD Information...
  • Page 243: Fcoe

    VPD information. For example: ------------------------------------------------------------------------- : 0 Port 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link : Online...
  • Page 244: Cna Vlan Information

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 ------------------------------------------------------------------------------ VLAN List:...
  • Page 245: Cna Fcoe Information (-Cna)

    (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 ------------------------------------------------------------------------------ Team: 1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 VLAN ID: None Team Type: Fail Over Team Members: CNA: 1 CNA Port: 1 MAC: 00:0e:1e:04:95:e8 Description: "QLogic Dual Port 10...
  • Page 246: Nic

    11–Converged Network Adapter Interactive Commands CNA FCoE Information (-cna) 1. Adapter Information1. Converged Network Adapter6. CNA FCoE Information<port selection>1. NIC From the CNA FCoE Information menu, select the NIC option to view FCoE NIC port information. For example: ------------------------------------------------------------------ -------------------------------- DCBX -------------------------------- DCBX Enable...
  • Page 247 11–Converged Network Adapter Interactive Commands CNA FCoE Information (-cna) CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EF WWNN : 20-00-00-0E-1E-04-95-EF Link : SFP not installed ======================================================= Information Data Center Bridging...
  • Page 248 Node Name : 20-00-00-0E-1E-04-95-EB Port Name : 21-00-00-0E-1E-04-95-EB HBA Description : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) ---------------------------- DCBX These DCBX values are the default card/local settings. To see the running/current settings, use the TLV option.
  • Page 249 11–Converged Network Adapter Interactive Commands CNA FCoE Information (-cna) CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link : Online ======================================================= Display Settings Auto Polling...
  • Page 250: Cna Iscsi Information

    11–Converged Network Adapter Interactive Commands CNA iSCSI Information ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 251: Cna Port Target/Lun Information

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 CNA Port Target/LUN Information...
  • Page 252 11–Converged Network Adapter Interactive Commands CNA Port Target/LUN Information State: Session Active HBA/Target/Lun Number = 1/2/0 Vend = IET ProdID = VIRTUAL-DISK ProdRv = 0 LunSize = 0.007 GB Target ID: 3 hba_no: 1 IP: 192.168.30.85 Port: 3260 TGT Instance #: 3 ISCSI Name: iqn.2010-03.com.apps4085:storage.disk1 Alias: State: Session Active...
  • Page 253: Fcoe

    Target List Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 254 11–Converged Network Adapter Interactive Commands CNA Port Target/LUN Information Please Enter Selection: 1 LUN List Menu HBA Instance 0 (QLE8242 Port 1) : Online Device Product Vendor: DGC Product ID : RAID 0 Product Rev : 0324 Node Name : 50-06-01-60-C1-E0-63-25 Port Name : 50-06-01-60-41-E0-63-25 Port ID...
  • Page 255: Adapter Configuration

    11–Converged Network Adapter Interactive Commands Adapter Configuration Adapter Configuration 2. Adapter Configuration1. CNA Configuration From the main menu, select the Adapter Configuration option, and then select the configuration type (CNA Configuration). The Converged Network Adapter (CNA) Protocol Type Selection menu presents options for FCoE, iSCSI, and NIC configuration.
  • Page 256: Adapter Alias (-Ha)

    (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 ======================================================= HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA HBA SN : AFE1224F05264 HBA Alias ======================================================= HBA Alias [None]:HBA1 Update completed.
  • Page 257: Adapter Port Alias (-Pa)

    11–Converged Network Adapter Interactive Commands CNA FCoE Configuration HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA HBA SN : AFE1224F05264 HBA Alias : HBA1 ======================================================= HBA Alias [HBA1]: Adapter Port Alias (-pa) 2.
  • Page 258: Hba Parameters

    HBA Parameters Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 259 11–Converged Network Adapter Interactive Commands CNA FCoE Configuration Display HBA Parameters 2. Adapter Configuration1. CNA Configuration1. CNA FCoE Configuration3. HBA Parameters 1. Display HBA Parameters From the HBA Parameters menu, select the Display HBA Parameters option to view adapter parameters. For example: ------------------------------------------------------------------------------ HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20 ------------------------------------------------------------------------------...
  • Page 260 11–Converged Network Adapter Interactive Commands CNA FCoE Configuration Hard Loop ID Loop Reset Delay (seconds) Enable BIOS Enable HBA Hard Loop ID Enable Fibre Channel Tape Support Operation Mode Interrupt Delay Timer (100ms) Execution Throttle Login Retry Count Port Down Retry Count Enable LIP Full Login Link Down Timeout (seconds) Enable Target Reset...
  • Page 261: Target Persistent Binding

    Target Persistent Binding Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 262 Target Persistent Binding Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 263 Target Persistent Binding Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 264: Boot Devices Configuration

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Boot Device Settings Menu...
  • Page 265 11–Converged Network Adapter Interactive Commands CNA FCoE Configuration : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB...
  • Page 266 Boot Device Settings Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 267: Virtual Ports (Npiv)

    Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB SN0054667-00 G 11-33...
  • Page 268 For example: Display vPorts Menu HBA Instance 0 (QLE8242 Port 1) : Online WWPN: 21-00-00-0E-1E-04-95-EB Desc: QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) 1: vPort 0: WWPN: 21-DD-00-0E-1E-04-95-EB Online [ ] 2: Select All 3: Proceed (p or 0: Previous Menu;...
  • Page 269 Create vPorts Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 270 11–Converged Network Adapter Interactive Commands CNA FCoE Configuration Desc: QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) 1: 21-7F-00-0E-1E-04-95-EB 2: 21-82-00-0E-1E-04-95-EB 3: 21-85-00-0E-1E-04-95-EB 4: Commit (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
  • Page 271: Target Link Speed (Iidma)

    Version 1.0.2 (Build 15) iiDMA Menu ======================================================= : 0 Port: 1 : AFE1224F05264 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA FW Version : 6.00.13 WWPN : 21-00-00-0E-1E-08-F2-10 WWNN : 20-00-00-0E-1E-08-F2-10 Link...
  • Page 272 Version 1.0.2 (Build 15) iiDMA Menu (Basic) ======================================================= : 0 Port: 1 : AFE1224F05264 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA FW Version : 6.00.13 WWPN : 21-00-00-0E-1E-08-F2-10 WWNN : 20-00-00-0E-1E-08-F2-10 Link...
  • Page 273 Version 1.0.2 (Build 15) iiDMA Menu ======================================================= : 0 Port: 1 : AFE1224F05264 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA FW Version : 6.00.13 WWPN : 21-00-00-0E-1E-08-F2-10 WWNN : 20-00-00-0E-1E-08-F2-10 Link...
  • Page 274 Version 1.0.2 (Build 15) iiDMA Menu (Advanced) ======================================================= : 0 Port: 1 : AFE1224F05264 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA FW Version : 6.00.13 WWPN : 21-00-00-0E-1E-08-F2-10 WWNN : 20-00-00-0E-1E-08-F2-10 Link...
  • Page 275: Driver Parameters

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Driver Settings Menu...
  • Page 276 11–Converged Network Adapter Interactive Commands CNA FCoE Configuration Present persistently bound target(s) plus any new target(s) with driver defaults 2. Adapter Configuration1. CNA Configuration1. CNA FCoE Configuration8. Driver Parameters<port selection>1. Present persistently bound targets plus any new targets with driver defaults From the Drive Settings Menu, select this option to view persistently bound target devices and new target devices with driver defaults.
  • Page 277: Selective Luns

    Please Enter Selection: 2 Selective LUNs Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 SN0054667-00 G 11-43...
  • Page 278 Selective LUN Menu (Configuration) ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 279 11–Converged Network Adapter Interactive Commands CNA FCoE Configuration Vendor : N/A Product ID : N/A Port Name : 20-70-00-C0-FF-D8-32-7F Port ID : 00-00-00 Bind : Yes Target ID (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Selective LUN Menu (Configuration) Disk...
  • Page 280 11–Converged Network Adapter Interactive Commands CNA FCoE Configuration All LUNs (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 Selective LUN Menu (Configuration) HBA Instance 0 (QLE8242 Port 1) : Online Target WWPN 50-06-01-60-41-E0-63-25 LUN 0: Enable...
  • Page 281: Qos

    Version 1.0.2 QoS Type Menu ======================================================= : 0 Port: 1 : AFE1224F05264 HBA Model : QLE8362 HBA Desc. : QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA FW Version : 6.00.13 WWPN : 21-00-00-0E-1E-08-F2-10 WWNN : 20-00-00-0E-1E-08-F2-10 Link : Online...
  • Page 282 QConvergeConsole Version 1.0.2 QoS Priority Menu HBA Instance 0 (QLE8362 Port 1) : Online WWPN: 21-00-00-0E-1E-08-F2-10 Desc: QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA HBA Model QLE8362 1: vPort 0: WWPN: 21-E4-00-0E-1E-08-F2-10 Online [Priority] [Enabled] [Unlocked] [High] 2: Apply QoS Settings (p or 0: Previous Menu;...
  • Page 283: Export (Save) Configuration

    11–Converged Network Adapter Interactive Commands CNA FCoE Configuration HBA Instance 0 (QLE8362 Virtual Port 0): Online WWPN: 21-E4-00-0E-1E-08-F2-10 Desc: QLE8362 QLogic 2-port 16Gb FC Adapter or 10Gb CNA Medium High (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
  • Page 284: Generate Reports

    Export (Save) Configuration ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version : 4.07.31 WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 285 HBA General Information ------------------------------------------------------------------------------ ------------------------------------------------------------------------------ Host Name : APPS4055 HBA Instance HBA Model : QLE8242 HBA Description : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) HBA ID : 0-QLE8242 HBA Alias HBA Port Port Alias Node Name : 20-00-00-0E-1E-04-95-EB...
  • Page 286: Personality

    2. Adapter Configuration1. CNA Configuration1. CNA FCoE Configuration13. Personality NOTE d ed  The personality feature is supported only on QLogic QLE267x and QLE836x Adapters. This feature lets you set the adapter’s personality to Fibre Channel only or Converged Network Adapter.
  • Page 287: Cna Iscsi Configuration

    Converged Network Adapter (CNA) iSCSI Configuration CNA Model QLE8242 SN: AFE1028C03899 1. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online 2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC SN0054667-00 G 11-53...
  • Page 288 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 HBA Level Parameter Configuration =======================================================...
  • Page 289: Port Configuration

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Port Link Configuration...
  • Page 290 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Port Link Settings Menu...
  • Page 291 4010 default port settings, and save changes. For example: Port Link Settings Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display Configured Port Settings...
  • Page 292 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Change Port iSCSI Alias Name Port Firmware Settings Menu Legacy 4010 Restore Default Port Settings Save changes and reset HBA (if necessary) Display Configure Port Settings Select this option to view the configured port settings.
  • Page 293 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display Configured Port Settings Edit A Specific Port Setting Configure ISCSI Settings...
  • Page 294 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration  Edit A Specific Port Setting—This option is currently not supported.  Configure ISCSI Settings (-n; -nh)—Select this option to configure iSCSI settings. For more information about these settings, refer to Table 7-3 on page 7-16.
  • Page 295 IPv4_TOS_ENABLE [off] : Force_Negotiate_Main_iSCSI_Keys [off] : iSCSI_Header_Digests [off] : iSCSI_Data_Digests [off] : iSCSI_Immediate_Data [on] : iSCSI_Initial_R2T [off] : KeepAliveTO [30] : MaxBurstLen [512] : MaxOutstandingR2T [1] : TCP_Time_Stamp [on] : TCP_Window_Scale [0] : iSCSI_Name [iqn.2000-04.com.qlogic:isp8214.000E1E0495EE.5] : ZIO [0] : SN0054667-00 G 11-61...
  • Page 296 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration IPv4TOS [0] : IPv4TTL [64] : IPv6_TCP_Time_Stamp [on] : IPv6_TCP_Window_Scale [0] : IPv6_VLAN_ID [0] : IPv6_VLAN_User_Priority [0] : IPv6_VLAN_Enable [off] : IPv6_Traffic_Class [0] : IPv6_Hop_Limit [64] (router may override) : IPv6_ND_Reachable_Timer [30000] (router may override) : IPv6_ND_Retransmit_Timer [1000] (router may override) : IPv6_ND_Stale_Timeout [600000] : IPv6_DAD_Count [1] :...
  • Page 297 Refresh—Select this option to refresh the adapter data. Legacy 4010 Restore Default Port Settings Select this option to restore QLogic 4010 iSCSI Adapter default port settings. (Note that QConvergeConsole CLI does not currently support the QLogic 4010 Adapter.) Save changes and reset HBA Select this option to save changes and reset the adapter.
  • Page 298 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Save changes Save changes and reset HBA (if necessary) Display BIOS/UEFI Information Select this option to view the BIOS and UEFI information. Set BIOS/UEFI Mode Select this option to set the BIOS and UEFI mode. Set Primary Boot Target Information Select this option to set the primary boot target parameters.
  • Page 299: Port Ip Settings

    Settings menu with options to view and configure IP settings. For example: Converged Network Adapter (CNA) iSCSI Configuration CNA Model QLE8242 SN: AFE1028C03899 1. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online 2. Port 2 [Protocol(s): NIC iSCSI FCoE] SN0054667-00 G 11-65...
  • Page 300 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Port IP Settings...
  • Page 301: Target Configuration

    Converged Network Adapter (CNA) iSCSI Configuration CNA Model QLE8242 SN: AFE1028C03899 1. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online 2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF SN0054667-00 G...
  • Page 302 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Target Configuration ======================================================= : 0 Port: 1...
  • Page 303 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration State: Session Active Target ID: 4 hba_no: 1 IP: 192.168.1.10 Port: 3260 TGT Instance #: 4 ISCSI Name: iqn.1992-04.com.emc:cx.apm00103600607.a2 Alias:0607.a2 State: Session Active ------------------------------------------------------------------ Display Target Information (-t) 2. Adapter Configuration1. CNA Configuration2. CNA iSCSI Configuration4. Target Configuration<port selection>2.
  • Page 304 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Delete Target 2. Adapter Configuration1. CNA Configuration2. CNA iSCSI Configuration4. Target Configuration<port selection>4. Delete Target Select the Delete Target option to delete a target device. For example: Target ID: 3 hba_no: 1 IP: 192.168.1.11 Port: 3260 TGT Instance #: 3...
  • Page 305 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration TGT_Port [3260] : TGTTCPO_Nagle [off] : TGTTCPO_Timestamp [on] : TGT_TaskManagementTimeout [10] : TGT_InitiatorSessID [0x000e1e0495ea] : TGT_TargetIPAddress [0.0.0.0] : TGT_Window_Scale_Enable [on] : TGT_Rx_Window_Scale [0] : TGT_Type_of_Service [0] : TGT_4022_Deleyed_ACK [off] : Add A Target (-pa) 2.
  • Page 306 CHAP entries, save changes, and refresh adapter data. For example: Configure Target Authentication Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display CHAP Table...
  • Page 307 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Save changes and reset HBA (if necessary) Refresh Display CHAP Table (-dspchap) Select this option to view the CHAP table. For example: ------------------------------------------------------------------ CHAP TABLE Entry: 1 Name: chap_target1 Secret: q1w2e3r4t5y6 Entry: 2 Name: chap_target2 Secret: a1s2d3f4g5h6 Entry: 3...
  • Page 308 Select this option to edit a CHAP entry. Delete a CHAP entry (-delchap) Select this option to delete a CHAP entry. For example: CHAP TABLE Entry: 1 Name: qlogic Secret: qle82xx55 Entry: 2 Name: abcd Secret: 1234567890asdfghjk This is a BIDI Chap Entry...
  • Page 309 For example: Target Discovery Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 ======================================================= Display Send Targets Display Discovered Targets...
  • Page 310 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration ------------------------------------------------------------------ Display Discovered Targets (-dtdsp) Select this option to view discovered target devices. For example: ------------------------------------------------------------------ Persistent Target List --------------------------------- 1. Target ID: 3 hba_no: 1 IP: 192.168.1.11 Port: 3260 ISCSI Name: iqn.1992-04.com.emc:cx.apm00103600607.b2 Alias: 0607.b2 ISID: 000e1e045242 State: Session Active...
  • Page 311 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Remove a Send Target (-strem) Select this option to remove a send target. For example: Persistent Send Target List ------------------------------ 1. hba_no: 1 IP: 192.168.1.11 2. hba_no: 1 IP: 192.168.1.100 Enter the instance number or ALL: 2 Login and persist a discovered target (-dtli;...
  • Page 312: Boot Devices Configuration

    For example: BIOS/UEFI Settings Menu ======================================================= : 0 Port: 1 : AFE1028C03899 CNA Model : QLE8242 iSCSI Name : iqn.2000-04.com.qlogic:isp8214.000E1E0495EA.4 FW Version : 4.7.31 iSCSI MacAddr : 00:0E:1E:04:95:EA IPv4 Address : 192.168.1.45 11-78 SN0054667-00 G...
  • Page 313 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration ======================================================= Display BIOS/UEFI Information Set BIOS/UEFI Mode Set Primary Boot Target Information Set Secondary Boot Target Information Clear Primary Boot Target Information Clear Secondary Boot Target Information Set Alternatve Client ID Save changes Save changes and reset HBA (if necessary) Display BIOS/UEFI Information (-binfo) 2.
  • Page 314 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Target ID: 6 hba_no: 1 IP: 192.168.30.85 Port: 3260 TGT Instance #: 6 ISCSI Name: iqn.2010-03.com.apps4085:storage.disk4 Alias: State: Session Active Enter a Target ID:2 Enter a LUN Number[0,(default 0)]: Set Secondary Boot Target Information 2.
  • Page 315: Export (Save) Configuration

    Converged Network Adapter (CNA) iSCSI Configuration CNA Model QLE8242 SN: AFE1028C03899 1. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online 2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF SN0054667-00 G...
  • Page 316 11–Converged Network Adapter Interactive Commands CNA iSCSI Configuration Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Export (Save) Configuration ======================================================= : 0 Port: 1...
  • Page 317: Cna Nic Configuration

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 SN0054667-00 G 11-83...
  • Page 318: Nic Port Setting Configuration

    Port Settings Menu ======================================================= : 1 Port 1 : AFE1028C03899 CNA Model : QLE8242 CNA Desc. : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter MPI Fw Version: 4.07.31 Physical MAC : 00-0E-1E-04-95-E8 LAA MAC : 00-0E-1E-04-95-E8 IPv4 Address : 192.168.10.55...
  • Page 319 11–Converged Network Adapter Interactive Commands CNA NIC Configuration IPv4_Large_Send_Offload_v1_Enable : on IPv4_Large_Send_Offload_v2_Enable : on IPv6_Large_Send_Offload_v2_Enable : on Receive_Side_Scaling_Enable : on Jumbo_Frames_MTU_9000_Enable : off LOCAL_Administered_Address_MAC : 00:0e:1e:04:95:ec Port_Alias : None Port_Wake_On_LAN_Option : Disabled Port_PXE_Enable : off Chimney_Mode : CPU Large_Receive_Offload : on Priority_Tagging : Rx Tx Enabled Flow_Control...
  • Page 320 11–Converged Network Adapter Interactive Commands CNA NIC Configuration IPv4_UDP_Checksum_Offload_Enable (off, Rx, Tx, RxTx)[RxTx]: IPv6_UDP_Checksum_Offload_Enable [RxTx]: IPv4_Large_Send_Offload_v1_Enable (on, off)[on]: IPv4_Large_Send_Offload_v2_Enable (on, off)[on]: IPv6_Large_Send_Offload_v2_Enable (on, off)[on]: Receive_Side_Scaling_Enable (on, off)[on]: Jumbo_Frames_MTU_9000_Enable (on, off)[off]: LOCAL_Administered_Address_MAC [00:0e:1e:04:95:ec]: WOL available options: 0 = Disabled, 1 = Wake on Magic Frame, Port_Wake_On_LAN_Option [Disabled]: Port_PXE_Enable (on, off)[off]: VLAN_ID (1..4094) [0]:...
  • Page 321: Vlan Configuration

    11–Converged Network Adapter Interactive Commands CNA NIC Configuration Successfully saved Port Alias Change MAC Alias Name 2. Adapter Configuration1. CNA Configuration3. CNA NIC Configuration2. NIC Port Setting Configuration<port selection>4. Change MAC Alias Name Select the Change MAC Alias Name option to change the port MAC alias. For example: Physical MAC Address : 00:0e:1e:04:95:ec...
  • Page 322 Updating VLANs info ... Done ... Available VLAN ID(s): 300, 0 Select VLAN ID: (or ALL) : 0 ***** VLAN: 0 ([Default Vlan][VLan Team]:QLogic Teaming Virtual Adapter) ***** Driver Name : QLogic Teaming Virtual Adapter Driver Version : 4.2.15.1125 Driver Date...
  • Page 323 1 CNA Port: VLAN ID: None MAC: 00:0e:1e:04:95:ec Description: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter #2 Select one or more ListIndices from the list (1,2): 1 Enter one or more VLAN ID(s) (1..4094) : 300 About to set VLAN ID(s): for ListIndex: 1 Successfully set VLAN ID(s).
  • Page 324 VLAN. For example: VLAN List: ListIndex: 1 CNA: 1 CNA Port: VLAN ID: 300,0(untag) MAC: 00:0e:1e:04:95:ec Description: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter #2 Select ListIndex from the list (1 or ALL): 11-90 SN0054667-00 G...
  • Page 325: Team Configuration

    11–Converged Network Adapter Interactive Commands CNA NIC Configuration Refresh 2. Adapter Configuration1. CNA Configuration3. CNA NIC Configuration3. VLAN Configuration6. Refresh From the Configure VLANs Menu, select the Refresh option to refresh the adapter information. For example: Refreshing CNA data ... Loading: 1.
  • Page 326 IPv4 Address : 169.254.247.129 Subnet Mask : 255.255.0.0 IPv6 Address : fe80::a8af:6f72:3a1e:f781 Link Status : Up Primary Member : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Updating parameters ... Plese wait ... Configurable Properties: ======================== 11-92 SN0054667-00 G...
  • Page 327 11–Converged Network Adapter Interactive Commands CNA NIC Configuration IFP_Jumbo_Packet_Size : 1514 IFP_LSO_IPv4_V1 : Enabled IFP_LSO_IPv4_V2 : Enabled IFP_LSO_IPv6_V2 : Enabled IFP_Checksum_Offload_IPv4 : RX and TX Enabled IFP_UDP_Checksum_Offload_IPv4 : RX and TX Enabled IFP_TCP_Checksum_Offload_IPv4 : RX and TX Enabled IFP_UDP_Checksum_Offload_IPv6 : RX and TX Enabled IFP_TCP_Checksum_Offload_IPv6 : RX and TX Enabled IFP_Large_RECV_Offload...
  • Page 328 Select one or more CNA Port Indices (2 or ALL) : 2 Do you want ot set primary? (yes, no) [yes]: Member selected as Primary: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Add Non-QLogic Ports as members? (yes, no) [no]: Updating parameters ...
  • Page 329 From the Configure Teams Menu, select the Configure Team Parameters option to configure team parameters. For example: Team Index: 1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 Select Team Index : 1 Updating parameters ... Plese wait ...
  • Page 330 1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 Select Team Index (or ALL) : 1 About to delete Team 1 Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3. Please wait Successfully deleted Team: 1, Team Description: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3.
  • Page 331 Gigabit Ethernet CNA, PCIe 2.0 Ada pter" Non-QLogic Port MAC: 00:23:7d:5f:30:2f Description: "Broadcom NetXtreme Gigabit Ethernet" Team Members: 1. Description: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Mac: 00:0e:1e:04:95:e8 Link Status: Down 2. Description: Broadcom NetXtreme Gigabit Ethernet SN0054667-00 G 11-97...
  • Page 332 Team Members valiable for selection: 2. Description: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Member selected as Primary: QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Saving team: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 About to save team config.
  • Page 333 Current selection: Team : [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 Primary : QLogic Dual Port 10 Gigabit Ethernet CNA, PCIe 2.0 Adapter Clear primary? (yes, no) [yes]: y Saving team: [Default Vlan][Team 2]:QLogic Teaming Virtual Adapter #3 About to save team config. Please wait ...
  • Page 334: Export (Save) Configuration

    From the Save/Restore VLAN/Teams Menu, select the Restore VLAN & Teaming Configuration option to restore the VLAN and teaming configuration. For example: Enter file name (or ENTER for vtstate-user.cfg) : Accessing file: C:\Program Files\QLogic Corporation\QConvergeConsoleCLI\vtstate-user.cfg Number of Teams: 0 ----------------...
  • Page 335: Adapter Updates

    11–Converged Network Adapter Interactive Commands Adapter Updates ---------------- Number of VLANS: 0 ---------------- Proceed to restore VLAN/Teaming? (yes, no) [yes]: y Attempting to restore TEAMs and VLANs if configured prior to vtdriver update. Refreshing interfaces ... Please wait ... Updating IP properties for all ports ... Please wait ... Adapter Updates 3.
  • Page 336: Flash Update

    2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Enter a file name or Hit <RETURN> to abort: parameter_filename...
  • Page 337: Drivers Update (-D)

    2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Enter a file name or Hit <RETURN> to abort: driver_file Firmware Preload Table Update (-u) 3.
  • Page 338: Firmware Serdes Table Update (-Sp)

    11–Converged Network Adapter Interactive Commands Firmware Serdes Table Update (-sp) Please Enter Selection: 1 Enter a file name or Hit <RETURN> to abort: fwpreload.dat Firmware Serdes Table Update (-sp) 3. Adapter Updates1. Converged Network Adapter5. FW Serdes Table Update NOTE This option is only for blades/mezzanine adapters.
  • Page 339: Register Test

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Register Test Starts ...
  • Page 340: Hardware Test

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Hardware Test Starts ...
  • Page 341: Interrupt Test

    11–Converged Network Adapter Interactive Commands Interrupt Test WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Flash Test Starts ... Flash Test Results:...
  • Page 342: Link Test

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Link Test Starts ...
  • Page 343: Nic

    Loopback Test ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link : Online...
  • Page 344 11–Converged Network Adapter Interactive Commands Loopback Test Display Test Parameters 4. Adapter Diagnostics1. Converged Network Adapter1. CNA Model6. Loopback Test<port selection>2. FCoE1. Display Test Parameters From the Loopback Test menu, select the Display Test Parameters option to view the loopback test parameters. For example: ------------------------------------------------------------------------------ HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20 ------------------------------------------------------------------------------...
  • Page 345: Iscsi

    ======================================================= : 1 Port: 2 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EF CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EF WWNN : 20-00-00-0E-1E-04-95-EF Link : SFP not installed...
  • Page 346: Read Write Buffer Test

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Read Write Buffer Test...
  • Page 347 11–Converged Network Adapter Interactive Commands Read Write Buffer Test Display Test Parameters 4. Adapter Diagnostics1. Converged Network Adapter7. Read Write Buffer Test<port selection>1. FCoE1. Display Test Parameters From the Read Write Buffer Test menu, select the Display Test Parameters option to view the read/write buffer test parameters. For example: ------------------------------------------------------------------------------ HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20 ------------------------------------------------------------------------------...
  • Page 348: Iscsi (-Rwt)

    Loopback Test ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link : Online...
  • Page 349: Beacon/Led Test

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 LED Test Starts ...
  • Page 350: General

    2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Transceiver Diagnostics Monitoring Interface (DMI)
  • Page 351: Details

    11–Converged Network Adapter Interactive Commands Transceiver Diagnostics Monitoring Interface (DMI) (-dmi) Details 4. Adapter Diagnostics1. Converged Network Adapter9. Transceiver Diagnostics Monitoring Interface (DMI)<port selection>2. Details From the Transceiver Diagnostics Monitoring Interface (DMI) menu, select the Details option to view detailed DMI diagnostic information. For example: ------------------------------------------------------------------------------ HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20 ------------------------------------------------------------------------------...
  • Page 352: Iscsi Adapter Diagnostics (-Dumpnvram)

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 iSCSI Adapter Diagnostics...
  • Page 353: Iscsi Port Diagnostics

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 iSCSI Port Diagnostics...
  • Page 354: Perform Read/Write Buffer Test

    11–Converged Network Adapter Interactive Commands iSCSI Port Logs Enter an IP Address:192.168.1.11 Enter the number of PING attempts to make:3 Enter the packet size in bytes for the PING [32]: Ping to 192.168.1.11 successful (1 of 3). Ping to 192.168.1.11 successful (2 of 3). Ping to 192.168.1.11 successful (3 of 3).
  • Page 355: Display Arp Table (-Arp)

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 iSCSI Port Logs...
  • Page 356: Display Connection Error Log (-Dce)

    11–Converged Network Adapter Interactive Commands iSCSI Port Logs Display Connection Error Log (-dce) 4. Adapter Diagnostics1. Converged Network Adapter12. iSCSI Port Logs<port selection>2. Display Connection Error Log From the iSCSI Port Logs menu, select the Display Connection Error Log option to view the connection error log. For example: inst 0 Number of entries = 0x2 (2) ======================= inst 0 Entry Index: 0...
  • Page 357: Display Neighbor Cache (Ipv6) (-Nc)

    11–Converged Network Adapter Interactive Commands iSCSI Port Logs inst 0 Number of displayed entries (for all target IDs) = 0x2 (2) inst 0 Elapsed 1331172 second(s) since last entry (15 days 9 hours 46 minutes 12 seconds) as of Fri Feb 18, 2011 02:04:52 PM Display Neighbor Cache (IPv6) (-nc) 4.
  • Page 358: Adapter Statistics

    Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online 2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) 11-124 SN0054667-00 G...
  • Page 359: Reset Nic Statistics

    Ethernet port statistics counters to zero. For example: CNA Model QLE8242 SN: AFE1028C03899 1. Port 1 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:E8 WWPN: 21-00-00-0E-1E-04-95-EB Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 Online 2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF SN0054667-00 G...
  • Page 360: Undo Reset Nic Statistics

    11–Converged Network Adapter Interactive Commands Undo Reset NIC Statistics Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Ethernet Statistics for the current port are reset Undo Reset NIC Statistics 5.
  • Page 361: Display Test Parameters (-Gs)

    HBA Statistics Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link : Online...
  • Page 362: Reset Test Parameters

    Configure Test Parameters Menu ======================================================= : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link : Online...
  • Page 363: Display Fcoe Port Link Status

    2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:95:EC WWPN: 21-00-00-0E-1E-04-95-EF Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214.0 SFP not installed (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 Link Statistics Menu...
  • Page 364: Display Test Parameters

    11–Converged Network Adapter Interactive Commands Display FCoE Port Link Status CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link : Online ======================================================= Display Test Parameters...
  • Page 365: Display Link Statistics (-Ls)

    Display FCoE Port Link Status : 0 Port: 1 : AFE1028C03899 ENode MacAddr : 00:0E:1E:04:95:EB CNA Model : QLE8242 CNA Desc. : QLE8242 QLogic Pci Express to 10GbE Dual Channel CNA (FCoE) FW Version WWPN : 21-00-00-0E-1E-04-95-EB WWNN : 20-00-00-0E-1E-04-95-EB Link...
  • Page 366: Display Iscsi Port Statistics (-Stat)

    Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214. Online 2. Port 2 [Protocol(s): NIC iSCSI FCoE] MAC Address: 00:0E:1E:04:97:74 WWPN: 21-00-00-0E-1E-04-97-77 Port iSCSI Name: iqn.2000-04.com.qlogic:isp8214. Link Down (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 2 ------------------------------------------------------------------------------ IPTxPacketsCount...
  • Page 367: Reset Iscsi Statistics

    11–Converged Network Adapter Interactive Commands Reset iSCSI Statistics IPv6InvalidAddressError IPv6ErrorPacketCount IPv6FragRxOverlapCount IPv6FragRxOutOfOrderCount IPv6DatagramReassemblyTO TCPTxSegmentsCount : 13986 TCPTxBytesCount : 550276 TCPRxSegmentsCount : 13971 TCPRxBytesCount : 3700532 TCPDuplicateACKRetrans TCPRetransTimerExpiredCount: 48 TCPRxDuplicateACKCount TCPRxPureACKCount TCPTxDelayedACKCount : 2526 TCPTxPureACKCount : 2530 TCPRxSegmentErrorCount TCPRxSegmentOutOfOrderCount: 0 TCPRxWindowProbeCount TCPRxWindowUpdateCount : 13979 TCPTxWindProbePersistCount : 0...
  • Page 368: Nic Partitioning (Npar) Information

    11–Converged Network Adapter Interactive Commands NIC Partitioning (NPAR) Information NIC Partitioning (NPAR) Information 6. NIC Partitioning (NPAR) Information NOTE SR-IOV and NPAR cannot be enabled at the same time. If SR-IOV is enabled on the host, all NPAR-related commands are disabled. From the main menu, select the NIC Partitioning (NPAR) Information option to open a menu with options to view NPAR adapter information and NPAR port information.
  • Page 369: Npar Port Information (-Pinfo)

    Select a port to view NPAR port information CNA Model QLE8242 SN: AFE1020C03263 1. Port Function 2 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:F9] Function 4 [Type: iSCSI] [iSCSI Name: iqn.2000-04.com.qlogic:isp...] Function 6 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:FB] 2. Port Function 1 [Type: NIC...
  • Page 370: Nic Partitioning (Npar) Configuration

    11–Converged Network Adapter Interactive Commands NIC Partitioning (NPAR) Configuration Function: 4 MAC: 00:0E:1E:04:84:FA Type: iSCSI Function: 6 MAC: 00:0E:1E:04:84:FB Type: NIC View all PCI Functions Information (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit) Please Enter Selection: 1 General information -------------------...
  • Page 371: Bandwidth Configuration

    Function 2 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:F9] Function 4 [Type: iSCSI] [iSCSI Name: iqn.2000-04.com.qlogic:isp . . .] Function 6 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:FB] (p or 0: Previous Menu; m or 98: Main Menu; ex or 99: Quit)
  • Page 372: Modify Maximum Bandwidth (-Setmaxbw)

    NIC Partitioning (NPAR) Port Configuration Selection CNA Model QLE8242 SN: AFE1020C03263 1. Port Function 2 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:F9] Function 4 [Type: iSCSI] [iSCSI Name: iqn.2000-04.com.qlogic:isp ...] Function 6 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:FB] 2. Port Function 1 [Type: NIC...
  • Page 373: Eswitch Configuration

    11–Converged Network Adapter Interactive Commands ESwitch Configuration ESwitch Configuration 7. NIC Partitioning (NPAR) Configuration2. ESwitch<port selection> From the NIC Partitioning (NPAR) Configuration menu, select the ESwitch Configuration option. From the port selection menu, select the port on which to configure the eSwitch. The eSwitch Configuration menu provides options to configure functions and restore a configured eSwitch.
  • Page 374: General Eswitch Statistics (-Eswitchstats)

    11–Converged Network Adapter Interactive Commands General ESwitch Statistics (-eswitchstats) Function 2 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:F9] Function 4 [Type: iSCSI] [iSCSI Name: iqn.2000-04.com.qlogic:isp...] Function 6 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:FB] 2. Port Function 1 [Type: NIC ] [MAC Address: 00:0E:1E:04:84:FC] Function 5 [Type: iSCSI] [iSCSI Name: iqn.2000-04.com.qlogic:isp...]...
  • Page 375: View All Eswitch Statistics (-Eswitchvportstats)

    11–Converged Network Adapter Interactive Commands View All ESwitch Statistics (-eswitchvportstats) View All ESwitch Statistics (-eswitchvportstats) 8. NIC Partitioning (NPAR) Statistics1. ESwitch Statistics<port selection>2. View All ESwitch Statistics From the ESwitch Statistics menu, select the View All ESwitch Statistics option to view all eSwitch statistics. For example: ESwitch Statistics ------------------- ESwitch instance number...
  • Page 376: Function X Eswitch Statistics

    6. Refresh From the main menu, select the Refresh option to refresh (reload) the adapters and adapter port indices. For example: Scanning for QLogic adapters, please wait... Using config file: C:\Program Files\...\iscli.cfg Using config file: C:\Program Files\...\netscli.cfg Loading: 1. CNA ... adapters, please wait...
  • Page 377: Help (-H)

    11–Converged Network Adapter Interactive Commands Help (-h) Scanning for QLogic adapters, please wait... Hit <Enter> to continue: When you run QConvergeConsole CLI, the CLI collects all relevant information, including the number of available ports and the state of each one. Between the...
  • Page 378 11–Converged Network Adapter Interactive Commands Exit 11-144 SN0054667-00 G...
  • Page 379: Setting Up Nic Partitioning (Npar) Using Interactive Commands

    For an overview of NPAR, refer to Appendix A NIC Partitioning (NPAR) Overview. NPAR is supported by the QLogic 3200 Series Intelligent Ethernet Adapters and 8200 Series Converged Network Adapters. For information about non-interactive mode NPAR commands, refer to Chapter 8 NIC Partitioning (NPAR) Noninteractive Commands.
  • Page 380: Selecting Option 6 To View Npar Information Options

    12–Setting Up NIC Partitioning (NPAR) Using Interactive Commands Setting Up NIC Partitions To set up NIC partitions using QConvergeConsole CLI: Start the QConvergeConsole CLI utility and select option 6: NIC (Figure 12-1). Partitioning <NPAR> Information Figure 12-1. Selecting Option 6 to View NPAR Information Options At the Select an NPAR Information Type prompt, select option 2: (Figure 12-2).
  • Page 381: Viewing Npar Configuration

    12–Setting Up NIC Partitioning (NPAR) Using Interactive Commands Setting Up NIC Partitions The NIC Partitioning <NPAR> Adapter Configuration Selection shows the current configuration (Figure 12-3). Figure 12-3. Viewing NPAR Configuration After viewing the NPAR information, return to the main menu and then select option 7: NIC Partitioning <NPAR>...
  • Page 382: Selecting To Modify Minimum Bandwidth

    12–Setting Up NIC Partitioning (NPAR) Using Interactive Commands Setting Up NIC Partitions From the NIC Partitioning <NPAR> Configuration Selection menu, select option 1: NPAR Configuration to display the NPAR Configuration menu, which provides the following options: 1: Bandwidth Configuration 2: Change PCI Function Personality Configure the bandwidth settings to meet your system requirements.
  • Page 383: Setting Bandwidth Changes To Persist

    12–Setting Up NIC Partitioning (NPAR) Using Interactive Commands Setting Up NIC Partitions Specify whether you want your bandwidth settings to persist across reboots by typing y for yes or n for no (Figure 12-6). Figure 12-6. Setting Bandwidth Changes to Persist Return to the NIC Partitioning <NPAR>...
  • Page 384: Selecting Function Type On Linux System

    12–Setting Up NIC Partitioning (NPAR) Using Interactive Commands Setting Up NIC Partitions Figure 12-7 shows the CLI commands leading to the option for changing a function type on a Linux system. Figure 12-7. Selecting Function Type on Linux System Return to the main menu, and then select option 8: NIC Partitioning <NPAR>...
  • Page 385: Nic Partitioning (Npar) Overview

    NIC Partitioning (NPAR) Overview This appendix provides the following information on NIC partitioning (NPAR): “What Is NPAR?” on page A-2  “NIC Partitioning Options” on page A-3   “Function Type Changes” on page A-5  “Quality of Service” on page A-6 ...
  • Page 386: What Is Npar

    (PCIe) that can have a device driver attached to it. The NPAR feature in QLogic adapters allows you to partition a single 10GbE NIC port into up to four individual partitions with user-configurable bandwidth and function type (or function protocol). The partitioning options are not limited to NIC, as the name NPAR indicates;...
  • Page 387: Qlogic Adapters That Support Npar

    8200 and 8300 Series Converged Network Adapters NIC Partitioning Options The NPAR feature in QLogic adapters provides the ability to create multiple PCIe physical functions for each physical 10GbE port on the adapter. Each PCIe function appears as an independent interface to the host operating system or hypervisor.
  • Page 388 A–NIC Partitioning (NPAR) Overview NIC Partitioning Options  Each physical port can have at most one iSCSI function and one FCoE function. Virtual Machine (VM) to VM Ethernet traffic between VMs on different vSwitches is routed via the eSwitch (on board the adapter) if the communicating VMs are attached to NIC partitions derived from the same physical port.
  • Page 389: Function Type Changes

    A–NIC Partitioning (NPAR) Overview Function Type Changes Function Type Changes Based on your operating environment, you can use your preferred management tool to change or disable PCI functions on either physical port. Using this feature lets you divide each physical port into up to four partitions, configured to support one of the following PCI function types: NIC, FCoE, or iSCSI.
  • Page 390: Quality Of Service

    Bandwidth Settings for DCBX and NPAR” on page A-10. Each physical port on a QLogic adapter can simultaneously send and receive data at up to 10Gbps in both directions. When the physical port is partitioned into four partitions, the port bandwidth is divided between each port partition according to traffic demands.
  • Page 391: Eswitch

    The ability to view eSwitch statistics depends on your operating environment and management tool. The QLogic drivers download the VM MAC addresses to the firmware. This function enables the firmware and hardware to switch the packets destined for VMs on the host.
  • Page 392: Npar Setup

    This section provides NPAR reference tables that you can use when configuring NIC partitions using QConvergeConsole CLI. Default Settings Before configuring NIC partitions, the QLogic Adapter appears as a simple dual-port 10GbE adapter with NPAR settings, as shown in Table A-2.
  • Page 393: Npar Configuration Parameters And Setup Tools

    Function Bandwidth Bandwidth Type (0–100%) (0–100%) QLogic QConvergeConsole CLI for supported Windows and Linux operating systems QLogic QConvergeConsole GUI for supported Windows and Linux operating systems Requires a system reboot to take effect. Refer to Table A-5 for the available function type options of each partition.
  • Page 394: Interoperation Of Bandwidth Settings For Dcbx And Npar

    A–NIC Partitioning (NPAR) Overview Interoperation of Bandwidth Settings for DCBX and NPAR Interoperation of Bandwidth Settings for DCBX and NPAR If you want to run iSCSI and NIC traffic together, DCBX can be used to set the bandwidth percentage to be shared among the iSCSI and NIC. If you want to run partitioned NIC traffic, NPAR should be used to set the percentage of bandwidth that will be shared among the multiple NIC partitions.
  • Page 395 A–NIC Partitioning (NPAR) Overview Using DCBX and NPAR to Set Bandwidth Table A-6 summarizes these guidelines. Table A-6. Using DCBX and NPAR for Bandwidth Settings To run these types of traffic: Use these tools: iSCSI Unpartitioned NIC Partitioned NIC DCBX NPAR —...
  • Page 396 A–NIC Partitioning (NPAR) Overview Using DCBX and NPAR to Set Bandwidth A-12 SN0054667-00 G...
  • Page 397: Glossary

    See CSV. adapter port Converged Network Adapter A port on the adapter board. QLogic Converged Network Adapters address resolution protocol support both data networking (TCP/IP) See ARP. and storage networking (Fibre Channel) traffic on a single I/O adapter using two...
  • Page 398 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series DCBX Data center bridging exchange protocol. Extensible firmware interface. A specifica- Used by data center bridging (DCB) tion that defines a software interface devices to exchange configuration infor- between an operating system and platform mation with directly connected peers.
  • Page 399 Internet small computer system interface. iiDMA Protocol that encapsulates data into IP Intelligent interleaved direct memory packets to send over Ethernet connec- access. A QLogic patent-pending feature tions. that ensures maximum link efficiency. link layer discovery protocol input/output control See LLDP.
  • Page 400 QConvergeConsole CLI or CLI commands. NIC partitioning NPAR. The NIC partitioning feature in message passing interface QLogic adapters allows you to partition a See MPI. single 10GbE NIC port into up to four individual partitions with user-configurable message signaled interrupts bandwidth and function type (or function See MSI.
  • Page 401 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series NPAR partitioning. Peripheral component interface. First released in 1992, PCI has been rapidly NVRAM evolving into a viable replacement for the Non-volatile random access memory. A ISA bus. It solves many of the problems type of memory that retains data (configu- with older architectures, while at the same ration settings) even when power is...
  • Page 402 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series ping Each physical port on a QLogic adapter can send and receive data at up to A computer network tool used to test 10Gbps in both directions at the same whether a specific host is reachable time.
  • Page 403 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Storage area network. Multiple storage Secure sockets layer. A cryptographic units (disk drives) and servers connected protocol that provides communications by networking topology. security over the Internet. SCSI storage area network Small computer system interface.
  • Page 404 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series  Type—A numeric code that indicates VLAN the kind of field that this part of the Virtual LAN. A group of hosts with a message represents. common set of requirements that commu- ...
  • Page 405 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series world wide unique LUN name See WWULN. World wide name. A unique 64-bit address assigned to a device by the device manufacturer. WWNN World wide node name. A unique 64-bit address assigned to a device.
  • Page 406 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series Glossary-10 SN0054667-00 G...
  • Page 407: Index

    Index adapter port alias name, changing 5-10, 11-23, 11-37 alias name, viewing 7-12 -acb configuration, viewing ACB firmware functions instance 7-12 adapter iSCSI name 7-12 alias name, changing 11-22 iSCSI, viewing list of 7-12 adapter alias number 7-12 defining 6-4, 9-5, 10-7 reports, generating for 10-35...
  • Page 408 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -ainfo adapters definition of Glossary-1 alias See Also adapter alias, adapter adapter, changing name 5-11, 11-22 configuration, adapter information, adapter, defining adapter parameters, adapter port iSCSI 7-16 ARP table, viewing port instance 7-12 complete information, showing 6-2,...
  • Page 409 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series changing BIOS enabling 6-28 adapter alias name 5-11, 11-22 information, viewing adapter port alias name 5-10, 11-23, 11-37 restoring default 6-27 CHAP entry 7-10 restoring settings 11-26 eSwitch physical function configuration eSwitch physical ports saving to file settings...
  • Page 410 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -eswitchinfo commands noninteractive mode, Fibre Channel -eswitchstats noninteractive mode, iSCSI -eswitchvportstats noninteractive mode, NIC -extloopback noninteractive mode, NPAR -f 6-13, 7-11 -feswitchcfg -acb 6-13 -addchap -finfo ainfo -flashsupport -arp 6-14 -b 6-7, -fwdump...
  • Page 411 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -pa 6-32, 6-33, 7-19 -teamnew_portspreview 5-17 -pad 7-19 7-27 7-19 -tp 6-38, 7-27 -pbootcode 7-19 -trans 5-19 -pdt 7-20 6-38 -pet 7-20 -updimages 5-19 -pinfo 5-11, 7-20 -v 5-20, 6-39 pinfo -ver 5-20,...
  • Page 412 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series configuring adapter alias name 5-11 -d 5-4, adapter personality 10-35 DAT file, configuration boot device 11-32 data center bridging 11-13 driver settings 6-14 data center bridging exchange protocol, See IPv6 settings 7-18 DCBX...
  • Page 413 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series discovered targets deleting adapter alias, Fibre Channel 6-17 duplicating boot device for adapter, disabling 6-12 log in all 7-10 CHAP entry log in specific non-persistent, viewing port alias, Fibre Channel 6-32, 6-33 persistent, viewing teams...
  • Page 414 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series EnableBIOS parameter 6-28 drivers See Also driver parameters EnableHardLoopID parameter 6-28 See Also driver restrictions EnableLIPFullLogin parameter 6-28 adapter, installing EnableLIPReset parameter 6-28 definition of Glossary-2 EnableTargetReset parameter 6-28 enabling package, pre-installing required...
  • Page 415: Dce Statistics Parameters

    User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series firmware -extloopback See Also firmware parameters area, saving (QLE2562 only) 6-38 area, updating (QLE2562 only) 6-38 default settings, restoring 7-22 -f 6-4, 6-13, 7-11 functions, ACB supported failover image, updating 5-19 API, Fibre Channel mini dump...
  • Page 416 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series FirstBurstLen parameter 7-16 Flash -h 5-7, 6-16, 7-12, BIOS, saving and updating 6-17 command for support hard disk space requirement retrieving NVRAM 7-10 hard loop ID, enabling 6-28 saving adapter parameters 10-34 HardLoopID parameter 6-28...
  • Page 417 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -ipdhcp 7-14 instance number IPR, setting 7-14 port 7-12 iSCSI instance (port), definition of Glossary-6 adapter information, viewing 11-4 CNA information, viewing 11-16 intelligent interleaved direct memory access, See iiDMA data digests 7-16 intended audience...
  • Page 418 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series LT parameter 6-22 LUN configuration -l 6-3, 6-23, 7-14 automatic 11-46 LACP, overriding 5-15, 11-93 manual 11-44 Large_Frames parameter 7-17 viewing 11-44 -lcd 7-15 LUNs boot target, clearing target beaconing 6-38 enabling and disabling 6-25...
  • Page 419 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series noninteractive mode -minidump 5-10 mode command format, Fibre Channel silent 6-36 command format, iSCSl -model 7-15 command format, NIC displaying error and exit information model, adapter 7-12 non-volatile random access memory, See NVRAM definition of Glossary-4...
  • Page 420 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series passive uninstall NVRAM definition of Glossary-5 path, definition of Glossary-5 dumping to file 7-10 7-19 parameters, restoring 11-26 -pbootcode 7-19 restoring factory default values 7-22 PCI Express, definition of Glossary-5 PCI, definition of Glossary-5...
  • Page 421 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series previewing port information CNA, viewing before adding VLAN 5-21 DCBX before deleting VLAN 5-21 FCoE, viewing 11-6 ports for new team 5-17 Fibre Channel, viewing 10-3 primary iSCSI, viewing 7-20, 11-7 boot target information, clearing NIC, viewing 5-11,...
  • Page 422 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series resetting random-access memory, See RAM 5-12 adapter -rdf 7-22 Ethernet statistics counters 5-12 -rdh 7-22 -restoreeswitchcfg restoring read/write buffer test adapter defaults, Fibre Channel 10-11 parameters, configuring for Fibre Channel 10-46 default firmware settings 7-22...
  • Page 423 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series small form-factor pluggable, See SFP saving Fcode snack, iSCSI 7-17 firmware area 6-38 software requirements Flash BIOS Solaris driver restriction host configuration 7-24 6-15 teaming configuration to file 5-24 installing QConvergeConsole on VLAN configuration to file 5-24...
  • Page 424 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series targets -sunreset 5-14 SUSE Linux, installing on definition of Glossary-7 sysfs beacon, starting and stopping 6-38 definition of Glossary-7 binding persistent 7-19, 10-20, 11-28 driver, Linux restriction 6-15 bound, displaying 7-20 CHAP entry, assigning 7-15...
  • Page 425 -teamlist 5-16 topology, viewing host 6-38 -teamnew 5-16 -tp 6-38, 7-27 -teamnew_portspreview 5-17 training offered by QLogic xxiv teams -trans 5-19 802.3 5-15 transceiver DMI data, displaying 5-19 allowing Converged Network 11-93 transmission control protocol, See TCP...
  • Page 426: Adapter Parameters

    User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series uninstalling QCC CLI from Windows command line QCC CLI from Windows Control Panel QCC CLI from Windows Start menu QCC CLI on Linux QCC CLI on Solaris updating adapter information display 9-15, 10-54, 11-142 adapter parameters 6-35...
  • Page 427 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series NPAR physical ports viewing adapter configuration NPAR port information adapter information, Fibre Channel 6-41 parameter settings adapter information, NIC 11-3 persistent target binding information 6-30 port configuration adapter target information 6-37 port configuration, iSCSI adapter types in system...
  • Page 428 User’s Guide—QConvergeConsole CLI 2400, 2500, 2600, 3200, 8100, 8200, 8300 Series -vlanadd_preview 5-21 -vlandel 5-21 definition of Glossary-8 -vlaninfo 5-22 disabling 5-6, 11-86 -vlanlist 5-22 disabling for port 11-86 VLANs enabling 11-86 enabling for port 11-86 definition of Glossary-8 adding to port 5-20, 5-21 NPAR supported functions configuration, restoring from file...
  • Page 430 UK | Ireland | Germany | France | India | Japan | China | Hong Kong | Singapore | Taiwan © 2010–2013 QLogic Corporation. Specifications are subject to change without notice. All rights reserved worldwide. QLogic, the QLogic logo, and QConvergeConsole are trademarks or registered trademarks of QLogic Corporation.

Table of Contents