Connecting The Eps-Ld To Power - Extreme Networks e” series Hardware Installation Manual

Table of Contents

Advertisement

Installing and Connecting Summit Power Supplies
To connect the EPS-LD cable:
1 Connect the keyed end of the EPS-LD cable to the power supply unit.
See Figure 60 to locate the connectors on the EPS-LD unit and on the switch.
2 Align and tighten the captive retaining screws on the connector.
3 Connect the other end of the EPS-LD cable to the Extreme switch.
The connector fits in only one direction.
Figure 60: Connecting an EPS-LD unit to a switch
EPS-LD
Extreme switch

Connecting the EPS-LD to Power

Make sure the EPS-LD is connected to the switch before you connect the AC power.
CAUTION
The EPS-LD unit does not have a switch for turning the unit on and off. You disconnect power to the
EPS-LD unit by removing the plug from the electrical outlet. Ensure that this connection is easily
accessible to you.
NOTE
Consider all the equipment connected to the power supply circuit to ensure that the circuit is not
overloaded. Use proper over-current protection, such as a circuit breaker, to prevent over-current
conditions.
To connect the EPS-LD to power:
1 Connect the AC input power cable to the AC connector on the EPS-LD unit.
2 Connect the other end of the AC cable to the electrical outlet.
Make sure the electrical outlet is properly grounded.
The Power LED on the front of the EPS-LD unit turns solid green to indicate that it is ready. Table 23
shows the possible LED status for the power supply.
120
Keyed end of
redundant power cable
To AC
Redundant
power cable
Slot for key
To AC
Extreme Networks Consolidated "e" and "i" Series Hardware Installation Guide
Collin's
ES4K021A
XM_053