Extreme Networks e” series Hardware Installation Manual page 320

Table of Contents

Advertisement

Switch Technical Specifications
Table 65: Summit 200 common specifications
Safety Standards
Operating Conditions
Certifications and Standards
Storage & Transportation
Conditions (Packaged):
Condition Standards
Power Cord Requirements
Usage Standards
320
o Operating Temperature Range 0°C to 40°C (32 F to 104 F)
o Operating Humidity:10% to 95% relative humidity, non-
condensing
o Operating Altitude 0-3000 meters (9,850ft)
o Operational Shock (Half Sine in Rack): 30 m/s2 (3g), 11ms,
60 Shocks
o Operational Sine Vibration (In Rack): 5-100-5 Hz @ 2/10G,
0-Peak, 1 Oct./min.
o Operational Random Vibration: 3-500MHz @ 1.5g rms
o Acoustic Sound: Declared Sound Power = < 6.3 belsA per
EN 300 753 (10-1997) in accordance with ISO 7779 & ISO
9296.
• Transportation Temperature:-40°C to 70°C (-40 F to 158 F)
• Storage and Transportation Humidity:10% to 95% relative
humidity, non-condensing
• Packaged Shock (Half Sine): 11ms, 100 m/s2, 300 Shocks
• Vibration, Sinusoidal 5-62 Hz, 5mm/s velocity,62-200 Hz,
0.2g
• Random Vibration: 5-20 Hz @ 1.0 ASD w/-3dB/oct. from
20-200 Hz
• 14 drops min on sides & corners @ 41"
• AC power cords are not provided with Extreme Networks
switches. To purchase an AC power cord, contact your
local Extreme Networks Channel Account Manager or
Sales Manager, or purchase a cord from your local
supplier.
• PSU used outside the US require obtaining a power cord
with certifications applicable to the country of interest.
• Power Cord IEC Connector: IEC 320 C13
• Power Cord Min Wire Size: 18 AWG (.823 mm2) copper
stranded
• Power Cord Max Length: 3m(10ft) End
• Power Cord Max Length: 3m(10ft)