Max Air Components

MC524 Monitor Interface

MONITOR-COMMS INTERFACE
MC
524
Figure 3-8 MC524 Front and Rear Panels
Power Switch: Powers the unit off/on.
In 1 (38-pin ELCO): Talk Back, Listen Back and Mic inputs. This connector receives four
stereo listen channels and two stereo talk mic inputs. Signals can be boosted or attenuated.
In a standard patch configuration, input cable fans out to 12 female XLRs.
In 2 (90-pin ELCO): Control Room Buses, Monitor A, B, C, D, and Solo buses inputs. This
connector receives eight Monitor A channels, and two channels each for Monitor B, C, D.
These signals can be attenuated only and are typically fed from the AM713.
Out 1 (90-pin ELCO): Monitor A, B, C, D Speaker outputs. This connector outputs eight
Control Room channels, eight Monitor A channels, and two channels each for Monitor B,
C, D, and Solo. The output cable fans out to two 38-pin ELCO/Edak connectors for the Eu-
phonix Patchbay.
Out 2 (90 pin ELCO): Control Room Speakers, Talk Back and Listen Back Preamp, and
Solo Buses outputs. This connector outputs eight Control Room Main channels, six Control
Room Alt 1 channels, two Control Room Alt 2 channels, four Listen pre, two talk pre and
two Solo channels. The output cable fans out to two 38-pin ELCO/Edak connectors for the
Euphonix Patchbay.
Out 3 (female DB25): Talk Back, Listen Back, and Solo Preamp outputs. This connector
outputs four Listen pre, two Talk Back pre and two Solo channels . Output cable fans out
to eight male XLRs.
Control (DB15): Input for digital control signal from Digital Pilot (Euphonix TCC bi-di-
rectional serial protocol). All patching, switching, and gain controls are communicated via
this connection as well as MC524 IP address.
AC Line In (IEC) and Fuse Tray: Accepts standard IEC power cord (provided). An
autoranging switching supply accepts voltages between 90–250 VAC, 50–60 Hz.