Emerson E2 Installation And Operation Manual page 229

For rx refrigeration, bx hvac, and cx convenience store controllers
Hide thumbs Also See for E2:
Table of Contents

Advertisement

Alarm Name
Normal Low Limit Exceeded
Not Enough Backed Memory
Not Enough Flash Memory
Not Enough Memory
Not Enough Scatch Pad Memory
Notice Limit Exceeded
Num. Of Events Exceeded Limit
Occupied Hi Limit Exceeded
Occupied Low Limit Exceeded
Off Time Exceeded Limit
Oil Failure Occurred
On Time Exceeded Limit
Open Wire
Overcurrent
Override Log lost - CRC Error
Override Lost Output Cleared
Override Operation Didn't Take
Override State Not Restored
Pad Memory Corrupted - Reboot
Part Cnfg Loss-Ptr
Default
Priority
User
An analog value has fallen below its programmed Lo
Limit setpoint.
10
The E2 tried to save data to the battery-backed mem-
ory, but the memory was full.
20
The E2 tried to save data to the flash memory, but the
memory was full.
10
The E2 tried to save data to unbacked memory, but
the memory was full.
50
The E2 tried to save data to the scratch pad memory,
but the memory was full.
User
An analog sensor's programmed notice limit has
been exceeded.
User
A digital value has transitioned ON more times than
its defined Number of Events setpoint.
User
An analog value has risen above its defined high limit
setpoint during OCCUPIED mode.
User
An analog value has fallen below its defined low
limit setpoint during the OCCUPIED mode.
User
A digital value has been OFF longer than its defined
Time Off Last setpoint.
User
An oil sensor for a compressor has detected a failure.
User
A digital value has been ON longer than its defined
Time On Last setpoint.
30
MultiFlex ESR controller has detected an open wire
on the valve input.
30
MultiFlex ESR controller has detected an overcurrent
condition on the valve.
20
An internal error in the E2 has resulted in a loss of the
override log.
20
A user tried to override an output on a CC-100, RT-
100, or similar Echelon device, but the override was
not performed successfully. Try the override com-
mand again. If this alarm persists, call Retail Solu-
tions service.
20
The E2 tried to carry out an override and was unsuc-
cessful.
50
An overridden input or output has remained in the
override state longer than its programmed time.
30
A problem with memory has resulted in a reset of the
E2.
15
Due to an internal error, part of E2's configuration
data has been lost.
Definition
Appendix C: Alarm Advisory Messages
-
C
11