Emerson E2 Installation And Operation Manual page 200

For rx refrigeration, bx hvac, and cx convenience store controllers
Hide thumbs Also See for E2:
Table of Contents

Advertisement

Menu Option
5 - Alarm Setup
6 - Logging Setup
7 - Network Setup
8 - Global Data
9 - Licensing
Table 12-2
- System Configuration Menu Options
The System Information Menu
Figure 12-6
- System Information Menu
The System Information menu is used to set up the E2.
The options in this menu allow setting up time and date,
passwords, toggle full options, general information about
the controller, and other important data.
12-4
E2 RX/BX/CX I&O Manual
Description
Set up dial-outs and alarm
reporting for the current E2.
Enter information about Logging
Group applications such as the
sampling frequency and total
number of samples.
Accesses the Network Setup
menu where you can view and/or
change the configuration of the
Echelon and RS485 I/O Net-
works, set up boards, controllers,
routers, and make controller
associations.
Configure one or more analog or
digital sensors to be used as
"global" values by all E2s.
Select this option to access the
License Report screen that lists
all the applications in E2 that are
currently licensed and the num-
ber of each type of applications
that are in use. You can also add
additional licenses by pressing
F1.
The System Information Menu is another menu used to
set up the E2. The options in this menu allow setting up
time and date, passwords, toggle full options, general
information about the controller, and other important data.
To open the System Information Menu:
1.
Press
2.
Press
(System Configuration)
3.
Press
(System Information)
The System Information menu contains nine menu
items:
Menu Option
1 - General Controller Info
2 - Time and Date
3 - Passwords/User Access
4 - Firmware Revision
5 - Service Actions
6 - Note Pad
7 - Display Users
8 - Toggle Full Options
9 - Application Default
Value Setup
Table 12-3
- System Information Menu Options
Actions Menu
Functions such as graphing, point logging, overriding,
expanded information, setup, detailed status, and manual
Description
Edit general information about
the E2, such as engineering
units, and summer/winter
change-over specifications.
Change the current date and
time, and specify date formats.
Set up usernames and pass-
words, and define security level
requirements.
Read-only information screen
that contains current system ver-
sion information
Set up system diagnostics (mem-
ory and execution info), and per-
form advanced functions
(system resets and firmware
update).
Writable field for technician to
make notes about changes made
or general information.
Enter information about Logging
Group applications such as the
sampling frequency and total
number of samples.
When set to on, FULL will
appear at the top right of the
screen and gives user full access
to options and applications.
Choose the default values most
appropriate to the refrigeration
control components in the sys-
tem.
026-1610 Rev 12 25-APR-2011