iSM03206: Data can not be received sequentially
during split mode.ip=<aaa...a>
port=<bbbbb> reason=(invalid
sequence) detail=<cc-dddd>
[Classification]
ERROR
[Explanation]
It shows that the data cannot be received sequentially during command split
transferring mode, and retries are failed.
aaa...a
bbbbb
cc-dddd
[Measures]
Check the status of the disk array, and remove the cause of failure. Restart the
monitoring manually if necessary.
iSM03220: Control path access failed.
file=<aaa...a> func=<bbb...b>
errno=<ccc> detail=<dd-eeee>
[Classification]
ERROR
[Explanation]
Error occurred in the access of the control path.
This message is output on UNIX system.
aaa...a
bbb...b
ccc
dd-eeee
[Measures]
Check the function name and error number, and resolve the hindrance. Restart
the monitoring manually if necessary.
: IP address
: Port number
: Detail information (This code isn't disorder reason but a value
for maintenance.)
: Special file name
: Function number
: Error number
: Detail information (This code isn't disorder reason but a value
for maintenance.)