NEC Storage Manager Messages Handbook page 42

Messages handbook
Table of Contents

Advertisement

iSM03131: Management of control path in
diskarray[<a>] failed. ip=<bbb...b>
port=<ccccc> func=<ddd...d>
reason=(timeout <eee>sec.)
detail=<ff-gggg>
[Classification]
NOTICE
[Explanation]
Failed in the inclusion of the control path due to time out.
a
bbb...b
ccccc
ddd...d
eee
ff-gggg
[Measures]
Remove the hindrance by checking the network connection status between iSM
server and disk array, and restart the server if necessary.
iSM03132: Management of control path in
diskarray[<a>] failed. ip=<bbb...b>
port=<ccccc> reason=(invalid
sequence) detail=<dd-eeee>
[Classification]
NOTICE
[Explanation]
Failed in the inclusion of the control path.
a
bbb...b
ccccc
dd-eeee
[Measures]
Settings of disk array may be incorrect (monitoring by the node running iSM
server via LAN may not be allowed). Check settings of disk array and remove
fault.
: Disk array specifying number in environment definition file
(UNIX system: 1 to 64, Windows system: 1 to 32)
: IP address
: Port number
: Function name
: Seconds of the time out
: Detail information (This code isn't disorder reason but a value
for maintenance.)
: Disk array specifying number in environment definition file
(UNIX system: 1 to 64, Windows system: 1 to 32)
: IP address
: Port number
: Detail information (This code isn't disorder reason but a value
for maintenance.)