iSM11758: System call error (error code=<aaa>)
[Classification]
[Explanation]
[Measures]
iSM11759: Failed to open control volume in
[Classification]
[Explanation]
[Measures]
ERROR
The system call failed when the Volume Table was created.
This message is output on UNIX system.
aaa
: Error code
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
230
231
If the operation trace is collected, use the information in the operation trace and
the error code to find the cause and remove it.

Diagnostic mode.

ERROR
Control volume cannot be opened in Diagnostic mode.
Check that LVM has not been activated on control volume and has not been
opened by other application in Diagnostic mode. Then retry processing.
254
fork() fail
rename() fail
opendir() fail
execvp() fail
system() fail
unlink() fail
fopen() fail
fwrite() fail
rm command fail
mv command fail
lsdev command fail
mknod command fail
mksf command fail
child process dissipation
scsi open fail
scsi inquiry fail
scsi sense fail
open() fail
stat() fail