Configuring E-Mail Alert Settings - Dell PS-M4110 User Manual

Firmware version 4.3
Hide thumbs Also See for PS-M4110:
Table of Contents

Advertisement

where<index> is a value between 1–4. CMC uses the index number to distinguish up to four configurable
destinations for traps alerts. Destinations may be specified as appropriately formatted numeric addresses (IPv6 or
IPv4), or Fully-Qualified Domain Names (FQDNs).
5.
Specify a destination IP address to receive the traps alert:
racadm config -g cfgTraps -o cfgTrapsAlertDestIPAddr <IP address> -i <index>
where<IP address> is a valid destination, and <index> is the index value specified in step 4.
6.
Specify the community name:
racadm config -g cfgTraps -o cfgTrapsCommunityName <community name> -i
<index>
where <community name> is the SNMP community to which the chassis belongs, and <index> is the index
value specified in steps 4 and 5.
You can configure up to four destinations to receive traps alerts. To add more destinations, repeat steps 2–6.
NOTE: The commands in steps 2–6 overwrites any existing settings configured for the index specified (1–4). To
determine whether an index has previously configured values, type: racadm getconfig -g
cfgTraps -i <index>. If the index is configured, values appear for the cfgTrapsAlertDestIPAddr and
cfgTrapsCommunityName objects.
7.
To test an event trap for an alert destination, type:
racadm testtrap -i <index>
where <index> is a value 1–4 representing the alert destination you want to test.
If you are not sure of the index number, use:
racadm getconfig -g cfgTraps -i <index>

Configuring E-Mail Alert Settings

When CMC detects a chassis event, such as an environmental warning or a component failure, it can be configured to
send an e-mail alert to one or more e-mail addresses.
You must configure the SMTP e-mail server to accept relayed emails from the CMC IP address, a feature which is
normally turned off in most mail servers due to security concerns. For instructions to do this in a secure manner, see the
documentation that was provided with the SMTP server.
NOTE: If your mail server is Microsoft Exchange Server 2007, make sure that iDRAC7 domain name is configured
for the mail server to receive the email alerts from iDRAC7.
NOTE: E-mail alerts support both IPv4 and IPv6 addresses. The DRAC DNS Domain Name must be specified when
using IPv6.
If your network has an SMTP server that releases and renews IP address leases periodically, and the addresses are
different, then there is a duration when this property setting does not work due to change in the specified SMTP server
IP address. In such cases, use the DNS name.
Configuring E-Mail Alert Settings Using CMC Web Interface
To configure the e-mail alert settings using Web interface:
1.
In the system tree, go to Chassis Overview , and then click Alerts → E-mail Alert Settings .
2.
Specify the SMTP e-mail server settings and the e-mail address(es) to receive the alerts. For information about the
CMC Online Help .
fields, see the
3.
Click Apply to save the settings.
4.
Click Send under Test E-mail to send a test e-mail to the specified e-mail alert destination.