Dell PS-M4110 User Manual page 224

Firmware version 4.3
Hide thumbs Also See for PS-M4110:
Table of Contents

Advertisement

Severity
Message
Critical
Mezz B<slot number> Status: Add-in Card
sensor for Mezz B<slot number>, install error
was asserted.
Critical
Mezz C<slot number> Status: Add-in Card
sensor for Mezz C<slot number>, install error
was asserted.
Critical
Drive <number> is removed.
Critical
Fault detected on Drive <number>.
Critical
The system board fail-safe voltage is outside
of the allowable range.
Critical
The watchdog timer expired.
Critical
The watchdog timer reset the system.
Critical
The watchdog timer powered off the system.
Critical
The watchdog timer power cycled the system. The iDRAC watchdog detected that the system has
Critical
Log is full.
Warning
Persistent correctable memory errors
detected on a memory device at location
<location>.
Warning
Persistent correctable memory error rate has
increased for a memory device at location
<location>.
Critical
Multi-bit memory errors detected on a memory
device at location <location>.
Critical
An I/O channel check NMI was detected on a
component at bus <number> device <number>
function <number>.
Critical
An I/O channel check NMI wa detected on a
component at slot <number>.
Critical
A PCI parity error was detected on a
component at bus <number> device <number>
function <number>.
224
Cause
Incorrect Mezzanine card installed for IO fabric.
Incorrect Mezzanine card installed for IO fabric.
Storage Drive was removed.
Storage Drive failed.
This event is generated when the system board
voltages are not at normal levels.
The iDRAC watchdog timer expires and no action is
set.
The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to reboot.
The iDRAC watchdog detected that the system has
crashed (timer expired because no response was
received from Host) and the action is set to power
off.
crashed (timer expired because no response was
received from Host) and the action is set to power
cycle.
The SEL device detects that only one entry can be
added to the SEL before it is full.
Correctable ECC errors reach a critical rate.
An uncorrectable ECC error was detected.
A critical interrupt is generated in the I/O Channel.
A critical interrupt is generated in the I/O Channel.
Parity error was detected on the PCI bus.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Chassis management controller

Table of Contents