Setting Chassis Physical Location And Chassis Name Using Racadm; Setting Date And Time On Cmc; Setting Date And Time On Cmc Using Cmc Web Interface; Setting Date And Time On Cmc Using Racadm - Dell PS-M4110 User Manual

Firmware version 4.3
Hide thumbs Also See for PS-M4110:
Table of Contents

Advertisement

NOTE: The Chassis Location field is optional. It is recommended to use the Data Center, Aisle, Rack, and Rack
Slot fields to indicate the physical location of the chassis.
3.
Click Apply. The settings are saved.

Setting Chassis Physical Location and Chassis Name Using RACADM

To set the chassis name or location, date and time using the command line interface, see the setsysinfo and
setchassisname commands. For more information, see

Setting Date and Time on CMC

You can set the date and time manually, or you can synchronize the date and time with a Network Time Protocol (NTP)
server.

Setting Date and Time on CMC Using CMC Web Interface

To set the date and time on CMC using the CMC Web interface:
1.
In the system tree, go to Chassis Overview, and then click Setup → Date/Time .
The Date/Time page is displayed.
2.
To synchronize the date and time with a Network Time Protocol (NTP) server, select Enable NTP and specify up to
three NTP servers.
3.
To set the date and time manually, clear Enable NTP and edit the Date and Time fields, select the Time Zone from
the drop-down menu, and then click Apply.

Setting Date and Time on CMC Using RACADM

To set the date and time using the command line interface, see the config command and cfgRemoteHosts database
property group sections in the

Configuring LEDs to Identify Components on the Chassis

You can set component LEDs for all or individual components (chassis, servers, and IOMs) to blink as a means of
identifying the component on the chassis.
NOTE: To modify these settings, you must have Chassis Configuration Administrator privilege.

Configuring LED Blinking Using CMC Web Interface

To enable blinking for one, multiple, or all component LEDs using the CMC Web interface:
1.
Go to any of the following pages:
Chassis Overview → Troubleshooting → Identify .
Chassis Overview → Chassis Controller → Troubleshooting → Identify.
Chassis Overview → Server Overview → Troubleshooting → Identify.
NOTE: Only servers can be selected on this page.
Chassis Overview → I/O Module Overview → Troubleshooting → Identify.
RACADM Command Line Reference Guide for iDRAC7 and CMC .