Viewing Flexaddress Information For All Servers; Viewing Flexaddress Information For Individual Servers - Dell PS-M4110 User Manual

Firmware version 4.3
Hide thumbs Also See for PS-M4110:
Table of Contents

Advertisement

The General Chassis Settings page is displayed.
The FlexAddress has a value Active or Not Active. The value Active indicates the feature is installed on the chassis and
Not Active indicates the feature is not installed and not in use on the chassis.
Use the following RACADM command to display FlexAddress status for the entire chassis:
racadm getflexaddr
To display FlexAddress status for a particular slot:
racadm getflexaddr [-i <slot#>]
<slot#> is a value from 1– 16.
where
For additional information on getflexaddr command, see the
CMC.

Viewing FlexAddress Information For All Servers

To view FlexAddress status for all the servers using CMC Web interface, in the system tree, go to Server Overview →
Properties → WWN/MAC .
The WWN/MAC Summary page is displayed that provides the WWN configuration and MAC addresses for all the slots
in the chassis.
Fabric A, Fabric B, and Fabric C display the type of the Input/Output fabric installed.
Fabric
Configuration
iDRAC displays the server management MAC address.
Displays FlexAddress configuration for each slot in the chassis. Information displayed includes:
WWN/MAC
Addresses
A green check mark indicates the active address type, either server-assigned or chassis-
assigned.
For information about the fields, see the

Viewing FlexAddress Information for Individual Servers

To view FlexAddress information for a particular server using the CMC Web interface:
1.
In the system tree, expand Server Overview.
All the servers (1–16) appear in the expanded Servers list.
2.
Click the server you want to view. .
The Server Status page is displayed
3.
Click the Setup tab, and then the FlexAddress subtab.
The FlexAddress page is displayed that provides the WWN configuration and MAC addresses for the selected
server. For more information, see the
152
NOTE: If Fabric A is enabled, unpopulated slots display chassis-assigned MAC addresses for
Fabric A and MAC or WWNs for Fabrics B and C if they are in use by populated slots.
iDRAC management controller is not a fabric but its FlexAddress is treated like one.
Slot number and location.
FlexAddress is active or not active.
Fabric type.
Server-assigned and chassis-assigned WWN/MAC addresses in use.
CMC Online Help.
CMC Online Help.