LCD screen message No CMC
Found.

Front Panel LCD Messages

This section contains two subsections that list error and status information that is displayed on the front panel LCD.
Error messages on the LCD have a format that is similar to the System Event Log (SEL) viewed from the CLI or Web
interface.
The tables in the error section list the error and warning messages that are displayed on the various LCD screens and
the possible cause of the message. Text enclosed in angled brackets (< >) indicates that the text may vary.
Status information on the LCD includes descriptive information about the modules in the chassis. The tables in this
section describe the information that is displayed for each component.

LCD Error Messages

Table 42. CMC Status Screens
Severity
Message
Critical
The CMC <number> battery failed.
Critical
CMC <number> LAN heartbeat was lost.
Warning
A firmware or software incompatibility detected
between iDRAC in slot <number> and CMC.
Warning
A firmware or software incompatibility detected
between system BIOS in slot <number> and
CMC.
Warning
A firmware or software incompatibility detected
between CMC 1 and CMC 2.
Table 43. Enclosure/Chassis Status Screen
Severity
Message
Critical
Fan <number> is removed.
Warning
Power supply redundancy is degraded.
Critical
Power supply redundancy is lost.
No CMC is present in the chassis.
The control panel cable
is not connected, or is
improperly connected.
Reseat cables.
Insert a CMC into the chassis or reseat
existing CMC if present.
Cause
CMC CMOS battery is missing or has no voltage.
The CMC NIC connection has been removed or is not
connected.
Firmware between the two devices does not match in
order to support one or more features.
Firmware between the two devices does not match in
order to support one or more features.
Firmware between the two devices does not match in
order to support one or more features.
Cause
This fan is required for proper cooling of the
enclosure/chassis.
One or more PSU have failed or removed and the
system can no longer support full PSU redundancy.
One or more PSU have failed or removed and the
system is no longer redundant.