Executing Power Control Operations On An Iom - Dell PS-M4110 User Manual

Firmware version 4.3
Hide thumbs Also See for PS-M4110:
Table of Contents

Advertisement

A dialog box appears requesting confirmation.
4.
Click OK to perform the power management action (for example, cause the server to reset).
Executing Power Control Operations on a Server Using CMC Web Interface
To execute power control operation for an individual server using the CMC Web interface:
1.
In the system tree, go to Chassis Overview and click Server Overview.
2.
Click on the server for which you want to execute the power control operation, and then click the Power tab.
The Server Power Management page is displayed.
3.
Select one of the following power control operation:
Power On Server
Power Off Server
Reset Server (warm boot)
Power Cycle Server (cold boot)
For information about the options, see the
4.
Click Apply.
A dialog box appears requesting confirmation.
5.
Click OK to perform the power management action (for example, cause the server to reset).
Executing Power Control Operations on a Server Using RACADM
To execute power control operations on a server using RACADM, open a serial/Telnet/SSH text console to CMC, log in,
and type:
racadm serveraction -m <module> <action>
module > specifies the server by its slot number (server-1 through server-16) in the chassis, and < action > is the
where <
operation you want to execute:
powerup, powerdown, powercycle, graceshutdown, or hardreset.

Executing Power Control Operations on an IOM

You can remotely execute a reset or power cycle on an individual IOM.
NOTE: To perform power management actions, you must have Chassis Configuration Administrator privilege.
Executing Power Control Operations on IOMs Using CMC Web Interface
To execute power control operations on an IOM using the CMC Web interface:
1.
In the system tree, go to Chassis Overview → I/O Module Overview and click Power.
The Power Control page is displayed.
2.
For the IOM in the list, from the drop-down menu, select the operation you want to execute (reset or power cycle).
3.
Click Apply.
A dialog box appears requesting confirmation.
4.
Click OK to perform the power management action (for example, cause the IOM to power cycle).
198
CMC Online Help .