The VLANs assigned to the selected IOMs are removed.
An Operation Successful message is displayed. The current VLAN settings that are assigned to the IOMs are
displayed in the VLAN Assignment Summary field.

Updating Untagged VLANs for IOMs Using CMC Web Interface

To update untagged VLANs for IOM(s) using the CMC Web interface:
1.
In the system tree, go to I/O Module Overview and click Setup → VLAN Manager .
The VLAN Manager page is displayed.
2.
In the Select I/O Module section, select the required IOMs.
3.
In the Specify Port Range section, select the range of fabric ports to be assigned to the selected IOM(s).
For information about the fields, see
4.
Select the Select/Deselect All option to apply the changes to all or no IOMs.
or
Select the check box against the specific slots to select the required IOMs.
5.
In the Edit VLANs section, select Update the Untagged VLANs in the drop down list and click Apply.
A warning message is displayed that the configurations of the existing untagged VLAN will be overwritten with the
configurations of the newly assigned untagged VLAN.
6.
Click OK to confirm.
The untagged VLANs are updated with the configurations of the newly assigned untagged VLAN.
An Operation Successful message is displayed. The current VLAN settings that are assigned to the IOMs are
displayed in the VLAN Assignment Summary field.

Resetting VLANs for IOMs Using CMC Web Interface

To reset VLANs for IOM(s) to default configurations using the CMC Web interface:
1.
In the system tree, go to I/O Module Overview and click Setup → VLAN Manager.
The VLAN Manager page is displayed.
2.
In the Select I/O Module section, select the required IOMs.
3.
In the Edit VLANs section, select Reset VLANs in the drop down list and click Apply.
A warning message is displayed indicating that the configurations of the existing VLANs will be overwritten with
the default configurations.
4.
Click OK to confirm.
The VLANs are assigned to the selected IOMs according to the default configurations.
An Operation Successful message is displayed. The current VLAN settings that are assigned to the IOMs are
displayed in the VLAN Assignment Summary field.

Managing Power Control Operation for IOMs

For information to set the power control operation for IOM(s), see

Enabling or Disabling LED Blinking for IOMs

For information to enable LED blinking for IOM(s), see