Severity
Message
Critical
The power supplies are not redundant.
Insufficient resources to maintain normal
operations.
Warning
The control panel ambient temperature is
greater than the upper warning threshold.
Critical
The control panel ambient temperature is
greater than the upper warning threshold.
Critical
CMC redundancy is lost.
Critical
All event logging is disabled.
Warning
Log is full.
Warning
Log is almost full.
Table 44. Fan Status Screens
Severity
Message
Critical
Fan <number> RPM is operating less than the
lower critical threshold.
Critical
Fan <number> RPM is operating greater than the
upper critical threshold.
Table 45. IOM Status Screens
Severity
Message
Warning
A fabric mismatch detected on I/O module
<number>.
Warning
A link tuning failure detected on I/O module
<number>.
Critical
A failure is detected on I/O module <number>.
Table 46. iKVM Status Screen
Severity
Message
Warning
Console is not available for Local KVM.
Critical
Local KVM can not detect any hosts.
Critical
OSCAR, on screen display is not functional
for the Local KVM.
Non- Recoverable
Local KVM is not functional, and is powered
off.
222
Cause
One or more PSU have failed or removed and the
system lacks sufficient power to maintain normal
operations. This could cause servers to power down.
Chassis/Enclosure intake temperature exceeded the
warning threshold.
Chassis/Enclosure intake temperature exceeded the
warning threshold.
CMC no longer redundant. This happens if the standby
CMC is removed.
The Chassis/Enclosure cannot store events to the
logs. This usually indicates a problem with the control
panel or control panel cable.
Chassis has detected that only one more entry can be
added to the CEL (hardware log) before it is full.
Chassis event log is 75% full.
Cause
The speed of the specified fan is not sufficient to
provide enough cooling to the system.
The speed of the specified fan is too high, usually due
to a broken fan blade.
Cause
The IO module fabric does not match that of the
server or the redundant I/O module.
The IO module could not be set to correctly use the
NIC on one or more servers.
The I/O module has a fault. The same error can also
happen if the I/O module is thermal-tripped.
Cause
Minor failure, such as corrupted firmware.
USB host enumeration failure.
OSCAR failure.
Serial RIP failure or USB host chip failure.