The Identify page is displayed.
2.
To enable blinking for a component LED, select required component and click Blink.
3.
To disable blinking for a component LED, clear the required component and click UnBlink.

Configuring LED Blinking Using RACADM

Open a serial/Telnet/SSH text console to CMC, log in, and type:
racadm setled -m <module> [-l <ledState>]
where <module> specifies the module whose LED you want to configure. Configuration options:
server-nx where
switch-n where
cmc-active
and <ledState> specifies whether the LED should blink. Configuration options:
0 — not blinking (default)
1 — blinking

Configuring CMC Properties

You can configure CMC properties such as power budgeting, network settings, users, and SNMP and e-mail alerts using
the Web interface or RACADM.

Understanding Redundant CMC Environment

You can install a standby CMC that takes over if your active CMC fails. The redundant CMC may be pre-installed or can
be installed later. It is important that CMC network is properly cabled to ensure full redundancy or best performance.
Failovers can occur when you:
Run the RACADM cmcchangeover command. (See the cmcchangeover command section in the
Command Line Reference Guide for iDRAC7 and CMC) .
Run the RACADM racreset command on the active CMC. (See the racreset command section in the
Command Line Reference Guide for iDRAC6 and CMC) .
Reset the active CMC from Web interface. (See the Reset CMC option for Power Control Operations that is
described in
Executing Power Control
Remove the network cable from the active CMC.
Remove the active CMC from the chassis.
Initiate a CMC firmware flash on the active CMC.
Have an active CMC that is no longer functional.
NOTE: In the event of a CMC failover, all iDRAC connections and all active CMC sessions are lost. Users
with lost sessions must reconnect to the new active CMC.
Related Links
About Standby CMC
CMC Failsafe Mode
Active CMC Election Process