Leak Testing - DCS BFG-30BS Use And Care & Installation Manual

Professional liberty collection
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION
LEAK TESTING - GRILL/GRIDDLE
UNIT
GENERAL:
Although
all gas connections
on the outdoor
appliance
are leak tested
at the factory
prior to shipment,
a
complete
gas tightness
check must be performed
at the installation
site due to possible
mishandling
in
shipment,
or excessive
pressure
unknowingly
being
applied
to the unit.
Periodically
check the whole
system for
leaks, or immediately
check if the smell of gas is detected.
Before
Testing:
Do not smoke
while
leak testing.
Extinguish
all open flames.
Never
leak test with
an open flame.
Makea
soap solution
of one part liquid
detergent
and one part water.
You will need a spray bottle,
brush, or rag to
apply the solution
to the fittings.
For LP units, check with
a full cylinder.
The valve panel must be removed
to
check the valves and fittings.
Remove the knobs, then
remove the 2 screws which
fasten the valve panel to the
unit (you will need a Phillips
screw driver for this).
Pull the valve panel outward
and unplug
the wires from the
ignition
module.
To Test:
Make sure all control
valves are in the "OFF" position.
Turn the gas supply
"on". Check all connections
from the
supply
line, or LP cylinder
up to and including
the manifold
pipe assembly.
Apply
the soap solution
around
the
connection,
valve, tubing
and end of the manifold.
Soap bubbles
will appear where a leak is present.
Ifaleakis
present,
immediately
turn off gas supply,
tighten
any leaking
connections,
turn gas on, and recheck.
Check all
the gas connections
at the base of the control
valves where they screw into the manifold
pipe.
If you cannot
stop a gas leak, turn off the gas supply
and call your
local gas utility,
or the dealer you purchased
the appliance
from.
Only those
parts recommended
by the manufacturer
should
be used on the outdoor
appliance.
Substitution
can void the warranty.
WARNING!
Do not use the outdoor appliance until all connections
have been checked and do not leak.
Check all gas supply fittings
for leaks before
each use. Keep a spray bottle
of soapy water
near the gas supply
shut-off
valve.
Spray all the fittings.
Bubbles
indicate
leaks.
Bottom
of unlt
/
LEAKTEST POINTS _ _ ::: _ %
2¢ .......
,:' ",",,
[
CHECKCHECK
HOSE FOR
L: .......
C
Fig. 30 LP Gas
Fig. 31 Nat. Gas