INSTALLATION
GAS HOOK-UP
GAS REQUIREMENT
Verify the type of gas supply
to be used, either
natural
or LID,and make sure the marking
on the appliance
rating
plate agrees with that of the supply.
The rating
plate is located
on the bottom
of the outdoor
appliance.
Never
connect
an unregulated
gas line to the appliance.
You must use the gas regulator
provided
with
the unit even if
the supply
is controlled.
An installer-supplied
gas shut-off
valve must be installed
in an easily accessible
location.
All installer
supplied
parts must conform
to local codes, or in the absence
of local codes, with
the National
Electrical
Code, ANSI/NFPA
70 or the Canadian
Electrical
Code, CSA C22.1, and the National
Fuel Gas Code, ANSI Z223.1 or CAN/CGA-B149.1
Natural
Gas Installation
Code or CAN/CGA-B149.2
Propane
Installation
Code.
All pipe sealants
must be an approved
type and resistant
to the actions
of LPgases.
Never use pipe sealant on
flare fittings.
All gas connections
should
be made by a qualified
technician
and in accordance
with
local codes
and ordinances.
In the absence
of local codes, the installation
must comply
with
the National
Fuel Gas Code,
ANSIZ223.1.
Gas conversion
kits are available
from the factory.
When ordering
gas conversion
kits, have the
model
number,
and the type of gas (natural
or LP) from your outdoor
appliance.
TOTAL
GAS CONSUMPTION
OF THE OUTDOOR
APPLIANCE
WITH
ALL BURNERS
ON
HI/SEAR:
BFG-30G - 50,000 Btu/hr
BFG-30BGD - 49,000
Btu/hr
BFG-30BS - 34,000 Btu/hr
The appliance
and its individual
shut-off
valve must be disconnected
from the gas supply
piping
system during
any pressure testing
of that system at test pressures
in excess of 1/2 PSIG (3.5 kPa.) The appliance
must be
isolated
from the gas supply
piping
system
by closing
its individual
manual
shut-off
valve during
any pressure
testing
of the gas supply
piping
system at test pressures
equal to or less than
1/2 PSIG (3.5 kPa.). The installation
of this appliance
must conform
with
local codes or, in the absence of local codes, with
the National
Fuel Gas
Code, ANSI Z223.1.
Installation
in Canada must be in accordance
with
the Standard
Canl-b149.1
and/or
.2
(installation
code for gas burning
appliances
and
equipment)
and local codes.
NATURAL
GAS HOOK
UP: (THIS TYPE OF
CONNECTION
SHOULD
BE PERFORMED
BY A
CERTIFIED
OR LICENSED TECHNICIAN
ONLY.)
Connection:
1/2" NPT male with
3/8" flare adapter.
Operating
pressure:
4.0" W.C. Supply
pressure:
5"
to 14" water column.
If in excess of 14" W.C., a step-
down
regulator
is required.
Check with your local
gas utility
company
or local codes for instructions
on
installing
gas supply
lines.
Be sure to check on type
and size of run, and how deep to bury the line.
If
the gas line is too small, the outdoor
appliance
will
not function
properly.
Any joint
sealant
used must
be an approved
type and be resistive
to the actions
of natural
gases.
TO HOOK-UP
THE FITTINGS
SUPPLIED
WITH
THE OUTDOOR
APPLIANCE:
Assemble
as shown
(Fig. 22). Use threading
compound
on male threads
only.
Do not use
threading
compound
on the male end of the 1/2"
NPT to 3/8 flare adapter.
Useasecond
pipe wrench
to hold the outdoor
appliance
inlet pipe to avoid
shifting
any internal
gas lines of the outdoor
appliance.
Ensure that the regulator
arrow points
in
c t
ottomoun
J
coupl
lng
Threading compound
"_,_ /
must be resistant to LP gas
/_
1/2" NPT x
_
2.0"
Nipple
__
Regulator
1/2" NPT x 5.0"
4.0" W.C.
Nipple
\Z/_
Adapter 1/2" NPT
/
to 3/8" flare fitting
Installer supplied shut-off
__
accessible_valve
must be easily
_
_
Do not put threading
compound
on these
_./'
threads
_lnstallation
must conform with local
codes or with the National Fuel Gas Code
ANSI Z223.1 or the CAN/CGA-B149.2
Propane Installation Code
Fig. 22 Natural Gas
the direction
of gas flow towards
the unit, away from the supply.
Do not forget
to place the installer-supplied
gas valve in an accessible
location.
16