Dell PowerEdge R810 Owner's Manual page 55

Hardware owner's manual
Hide thumbs Also See for PowerEdge R810:
Table of Contents

Advertisement

Message
Unable to launch
System Services
image. System
halted!
Unexpected
interrupt in
protected mode.
Unsupported CPU
combination
Unsupported CPU
stepping
detected
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
Causes
System halted after F10
keystroke because System
Services image is either
corrupted in the system
firmware or has been lost due
to system board replacement.
The iDRAC6 Enterprise card
flash memory may be
corrupted.
Improperly seated memory
modules or faulty
keyboard/mouse controller
chip.
Processor(s) is not supported
by the system.
A fatal system error occurred
and caused the system to
reboot.
Corrective Actions
Restart the system and
update the Lifecycle
Controller repository to the
latest software to restore full
functionality. See the
Lifecycle Controller user
documentation for more
information.
Restore the flash memory
using the latest version on
support.dell.com. See the
iDRAC6 user's guide for
instructions on performing a
field replacement of the flash
memory.
Reseat the memory modules.
See "Troubleshooting System
Memory" on page 169. If the
problem persists, see
"Getting Help" on page 195.
Install a supported processor
or processor combination.
See "Processors" on page 133.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 161 for
any faulty components
specified in the SEL.
About Your System
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents