Code
Text
E2112 Memory spared
on Card x
DIMM ##.
Power cycle
AC
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC.
I1910 Intrusion
detected.
Check chassis
cover.
I1911 LCD Log Full.
Check SEL to
review all
Errors.
I1912 SEL full.
Review &
clear log.
W1228 RAID
Controller
battery
capacity <
24hr.
38
About Your System
Causes
The system BIOS spared the
memory because it
determined that the
memory has too many
errors.
The system BIOS disabled
memory mirroring because
it has determined one half
of the mirror has had too
many errors. "## & ##"
represents the memory
module pair implicated by
the BIOS.
System cover removed.
LCD overflow message. A
maximum of ten error
messages can display
sequentially on the LCD.
The eleventh message
instructs the user to check
the SEL for details on the
events.
The SEL is full of events
and is unable to log any
more.
Warns predictively that the
RAID battery has less than
24 hours of charge left.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 169.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory" on
page 169.
Information only.
Check the SEL for details
on the events.
Remove AC power to the
system for 10 seconds or
clear the SEL.
Check the SEL for more
information and then
clear the SEL.
Allow RAID battery to
charge to greater than 24
hours of sustained charge.
If problem persists,
replace the RAID battery.
See "Installing the RAID
Battery" on page 130.