Cooling Fans; Removing A Cooling Fan - Dell PowerEdge R810 Owner's Manual

Hardware owner's manual
Hide thumbs Also See for PowerEdge R810:
Table of Contents

Advertisement

4 Remove the cooling shroud. See "Removing the Cooling Shroud" on
page 96.
5 Slide the front-chassis assembly away from the chassis. See "Front-Chassis
Assembly" on page 98.
6 Press down and out on the ejectors on each end of the socket until the
memory module pops out of the socket. See Figure 3-11.
7 Lift out the memory module.
NOTE:
blank in the socket.
8 Slide the front-chassis assembly back into the chassis. See "Front-Chassis
Assembly" on page 98.
9 If applicable, install the front bezel. See "Installing the Front Bezel" on
page 83.
10 Close the system. See "Closing the System" on page 85.
11 Reconnect the system and peripherals to their power sources, and turn
them on.

Cooling Fans

Your system contains six hot-swappable fans mounted in a cooling fan
assembly and provides cooling for the processors, expansion cards, and
memory modules.
NOTE:
In the event of a problem with a particular fan, the fan number is referenced
by the system's management software, allowing you to easily identify and replace
the proper fan by noting the fan numbers on the cooling fan assembly.

Removing a Cooling Fan

WARNING:
expose you to a risk of electric shock. Exercise utmost care while removing or
installing cooling fans.
WARNING:
system.
WARNING:
108
Installing System Components
If you are not replacing the memory module, insert a memory module
Opening or removing the system cover when the system is on may
Allow time for the fan to stop spinning after removing it from the
Do not attempt to operate the system without the cooling fans.