Viewing Status Messages

If a system error occurs, the LCD screen will turn amber. Press the Select
button to view the list of errors or status messages. Use the left and right
buttons to highlight an error number, and press Select to view the error.

Removing LCD Status Messages

For faults associated with sensors, such as temperature, voltage, fans, and so
on, the LCD message is automatically removed when that sensor returns to a
normal state. For other faults, you must take action to remove the message
from the display:
Clear the SEL — You can perform this task remotely, but you will lose the
event history for the system.
Power cycle — Turn off the system and disconnect it from the electrical
outlet; wait approximately 10 seconds, reconnect the power cable, and
restart the system.
NOTE:
The following LCD status messages are displayed in the Simple format. See
"Setup Menu" on page 16 to select the format in which the messages are displayed.
Table 1-1. LCD Status Messages
Code
Text
E1000 Failsafe
voltage
error.
Contact
support.
E1114 Ambient Temp
exceeds
allowed
range.
Causes
Check the system event log
for critical failure events.
Ambient temperature
reached a point outside the
allowed range.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
See "Troubleshooting
System Cooling
Problems" on page 167.