Code
Text
E1714 Unknown
error. Review
& clear SEL.
E1715 Fatal I/O
Error. Review
& clear SEL.
E1716 Chipset IERR
Bus ## Dev ##
Function ##.
Review &
clear SEL.
E1717 CPU #
internal
error. Review
& clear SEL.
Causes
The system BIOS
determined there has been
an error in the system, but is
unable to determine its
origin.
The system BIOS
determined there has been a
fatal error in the system.
The system BIOS reported a
chipset internal error that
resides in bus ##, device
##, function ##.
The system BIOS
determined that the
specified processor has had
an internal error.
Corrective Actions
Check the SEL for more
information and then
clear the SEL. Remove
AC power to the system
for 10 seconds and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.
Check the SEL for more
information, and then
clear the SEL. Remove
AC power to the system
for 10 seconds, and restart
the system.
If the problem persists,
see "Getting Help" on
page 195.