9 Close the system. See "Closing the System" on page 85.
10 Reconnect the system to its electrical outlet, and turn on the system and
attached peripherals.
11 Enter the System Setup program and check the system memory setting.
See "Memory Settings Screen" on page 63.
If the problem is not resolved, proceed with the next step.
12 If a diagnostic test or error message indicates a specific memory module as
faulty, swap or replace the module.
13 Open the system. See "Opening the System" on page 84.
14 To troubleshoot an unspecified faulty memory module, replace the
memory module in the first DIMM socket with a module of the same type
and capacity. See "Installing Memory Modules" on page 105.
15 Close the system. See "Closing the System" on page 85.
16 Reconnect the system to its electrical outlet, and turn on the system and
attached peripherals.
17 As the system boots, observe any error message that appears and the
diagnostic indicators on the front of the system.
18 If the memory problem is still indicated, repeat step 12 through step 15 for
each memory module installed.
If the problem persists after all memory modules have been checked, see
"Getting Help" on page 195.