Code
Text
E122C CPU Power
Fault. Power
cycle AC.
E122D Memory
Regulator #
Failed.
Reseat DIMMs.
E122E On-board
regulator
failed. Call
support.
E1243 CPU # VCORE
Regulator
failure.
Contact
Support
E1245 CPU # VIO
Regulator
failure.
Contact
support
E1310 Fan ## RPM
exceeding
range. Check
fan.
Causes
A power fault detected when
powering up the
processor(s).
One of the memory
regulators failed.
One of the on-board voltage
regulators failed.
Processor voltage regulator
failed.
Processor voltage regulator
failed.
RPM of specified fan is
outside the intended
operating range.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 169.
If the problem persists,
see "Getting Help" on
page 195.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
Reseat the processor. See
"Troubleshooting the
Processors" on page 178.
If the problem persists,
see "Getting Help" on
page 195.
Reseat the processor.
"Troubleshooting the
Processors" on page 178.
If the problem persists,
see "Getting Help" on
page 195.
See "Troubleshooting
System Cooling
Problems" on page 167.