Dell PowerEdge R810 Owner's Manual page 28

Hardware owner's manual
Hide thumbs Also See for PowerEdge R810:
Table of Contents

Advertisement

Code
Text
E1422 CPU # machine
check error.
Power cycle
AC.
E1610 Power Supply
# (### W)
missing.
Check power
supply.
E1614 Power Supply
# (### W)
error. Check
power supply.
E1618 Predictive
failure on
Power Supply
# (### W).
Check PSU.
E161C Power Supply
# (### W)
lost AC
power. Check
PSU cables.
E1620 Power Supply
# (### W) AC
power error.
Check PSU
cables.
28
About Your System
Causes
The system BIOS reported a
machine check error.
Specified power supply
removed or is missing from
the system.
Specified power supply
failed.
A power supply fan failure,
an over-temperature
condition, or power supply
communication error caused
the predictive warning of an
impending power supply
failure.
Specified power supply
attached to the system, but
lost its AC input.
Specified power supply's AC
input is outside the
allowable range.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 195.
See "Troubleshooting
Power Supplies" on
page 167.
See "Troubleshooting
Power Supplies" on
page 167.
See "Troubleshooting
Power Supplies" on
page 167.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 167.
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies" on page 167.

Hide quick links: