IC-R
Users Manual
INSTALLATION
GENERAL INfORMATION
inch of separation from the nearest surface.
Optional hinge kits allow wall mounted column arrays to be rotated 90 degrees away from the wall to provide easy access to the rear ac-
cess ports during installation and for routine testing and service. They also provide the separation needed for cooling.
The actual installation should be made either by or under the close supervision of someone experienced in installation techniques and
rigging.

WALL MOUNTING

If you ordered HK series hinge kits with your array. they will be packed in one of the cartons. Each mounting plate has hinges on both the
IC16-R, IC24-R and IC32-R columns will have three hinge sections.
The female hinges should be attached to the column and the male hinges to the wall. Refer to page 72 for dimensional details. The photos
below show the male mounting plates.
Notice that one of the wall mounting hinge plates has a metal strap attached to it. This is the hinge plate that goes on the bottom. The
metal strap attaches to the bottom of the array after it is hung and is used to lock the column array in place.
Hint:
column out of heavy plywood and mount the hinge plates on it. It's a lot easier to align the
hinge sections on a piece of plywood than it is on the wall. Then, when the alignment is
perfect they mount the "backing plate" to the wall. After that, it's usually a comparatively
easy task to hang the column array on the backing plate.
After the column array is hung on the wall, remove the machine screw from the center of the bottom end cap and use it to attach the