Download Print this page

Advertisement

IC Live
Digitally Steerable Line Array Loudspeaker Systems
IC Live Gen5
USERS MANUAL
Assembly & Installation Instructions
ICL-F-RN • ICL-F-DUAL-RN • ICL-F-TRIP-RN

Advertisement

loading

Summary of Contents for Renkus-Heinz ICL-F-RN

  • Page 1 IC Live Digitally Steerable Line Array Loudspeaker Systems IC Live Gen5 USERS MANUAL Assembly & Installation Instructions ICL-F-RN • ICL-F-DUAL-RN • ICL-F-TRIP-RN...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS Read these instructions. 11. Make sure the power cord remains readily accessible at Keep these instructions. all times. Heed all warnings. 12. The AC Power Cord is the AC Mains disconnect. Follow all instructions 13. Only use attachments/accessories specified by the Do not use this apparatus near water.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS PAGE INTRODUCTION ASSEMBLY INSTRUCTIONS INSTALLATION HARDWARE CONNECTIONS & INDICATORS FIRMWARE UPDATE SERVICING AND TROUBLESHOOTING USER NOTES...
  • Page 4: Introduction

    If you have any questions about Renkus-Heinz loudspeakers or encounter a problem designing, installing, setting up or operating a Renkus-Heinz system, please call our technical support staff at +1 949-588-9997 and ask the operator for technical support. Hours of operation are Monday through Friday from 8:00 AM to 5:00 PM US Pacific Time.
  • Page 5: Assembly Instructions

    Renkus-Heinz engineering has programmed the on board DSP to optimize the loudspeaker’s performance and to ensure its safe operation. Replace the amplifier module only with another unit that has been factory programmed for the same loud- speaker.
  • Page 6 IC Live Users Manual To join IC Live modules into a dual or triple array, you will use the included ICL- F-KIT-UP joining kits. Each kit contains two heavy metal joining plates. The first assembly step for a dual is to remove the top of both modules. To remove the top, remove the eight machine screws from each side of the cabinet and lift the end piece and its mounting brackets out of the cabinet.
  • Page 7 IC Live Users Manual Address Number Verification Next is to verify that the Slave modules are properly identified. The settings were set at the factory, but it’s always a good idea to check them. This is accomplished with the dip switches located on the rear of each module. Set the switches in ac- cordance with the illustrations shown below.
  • Page 8: Installation

    IC Live Users Manual INSTALLATION General Information IC Live Gen 5 hardware was designed to be easy to install on a flat surface, such as a wall. Note that it was not designed to be mounted in the wall or in an alcove. The amplifiers are convection cooled and their heat sinks require at least an inch of separation from the nearest surface.
  • Page 9 These loudspeakers have not been evaluated for safety requirements using other mounting kits. Renkus-Heinz is not responsible for the quality or effectiveness of an installer’s mounting of this heavy load to the wall type encountered during installation.
  • Page 10 IC Live Users Manual Wall Mounting Procedure NOTE: Each HK series hinge consists of two parts, a male mounting plate and a female mounting plate. The female hinge plates should be attached to the loudspeakers. The male mounting plates attach to the wall. The proper number of mounting plates are included for the size of loudspeaker ordered.
  • Page 11: Hardware Connections & Indicators

    IC Live Users Manual HARDWARE CONNECTIONS & INDICA- TORS AES/EBU Input Fault Relay Fault Relay NO / NC relay Pins NC, W and NO contacts used to see Fault Relay at left for details Ethernet Connection report a failure to an RJ-45 female: Yellow LED flashes when the connec- external monitoring tor is active, glows steadily when data is streaming.
  • Page 12: Firmware Update

    Subsequently loading the saved Preset will return the loud- speaker’s tuning settings. Download the necessary firmware or latest RHAON II version from the Renkus-Heinz website, as directed by Technical Support. Connect the loudspeaker(s) to be updated to your computer’s Ethernet port – directly or via a switch. The com- puter’s NIC should be set to obtain an IP address automatically.
  • Page 13: Servicing And Troubleshooting

    IC Live Users Manual SERVICING AND TROUBLESHOOTING Your Iconyx Gen 5 steerable column array contains no user-serviceable parts. All service should be referred to quali- fied service personnel. Great care was taken in its design, however, to allow it to be serviced in the field without being removed from its mounting position.
  • Page 14 IC Live Users Manual Network Connectivity Some common symptoms of network connectivity problems include: - Red Network Error indicator in a Device’s Zone view - Cannot use a Device (add to Devices or Zones) that appears in Network Discovery - Errors when writing beams Solutions to the above problems may include the following cable work: - Check for split pairs.
  • Page 15: User Notes

    IC Live Users Manual USER NOTES...
  • Page 16 19201 Cook Street, Foothill Ranch, CA USA Phone: +1 949 588 9997 • Fax: +1 949 588 9514 sales@renkus-heinz.com • www.renkus-heinz.com RH 821 Rev A September 2015...

This manual is also suitable for:

Icl-f-trip-rnIcl-f-dual-rnIc live gen 5